孕期使用0.55T低场强胎儿MRI的可靠性与可行性
前瞻性研究在伦敦圣托马斯医院纳入47名健康孕妇和32名妊娠相关异常孕妇,共79次胎儿MRI检查,采用商用0.55T扫描仪和20分钟方案(解剖T2加权快速自旋回波、定量T2*和扩散序列)。关键解剖二维测量与大型1.5T和3T对照研究一致,双顶径观察者间相关性在异常组为0.96、对照组为0.93,胎盘和脑T2*及胎盘ADC值与孕龄强相关(对照胎盘T2*每周衰减5.2毫秒,R²=0.66,30周平均T2*为176.6毫秒,P<.001)。结论认为该20分钟低场强胎儿MRI方案能可靠地产出胎儿和胎盘的结构与功能测量。
要点
- 0.55T低场强胎儿MRI的20分钟方案可完成解剖T2加权、定量T2*和扩散序列扫描。
- 双顶径观察者间相关性在异常组为0.96、对照组为0.93,健康组关键解剖测量与1.5T和3T对照研究一致。
- 对照胎盘T2*随孕龄每周衰减5.2毫秒(R²=0.66),30周平均T2*为176.6毫秒。
核心结论
- 20分钟低场强胎儿MRI检查方案能在孕期可靠地产出胎儿和胎盘的结构与功能测量。
研究设计与样本
- 前瞻性研究,2022年5月至11月在伦敦圣托马斯医院进行,使用商用0.55T MRI扫描仪,纳入47名健康孕妇和32名妊娠相关异常孕妇,共79次胎儿MRI检查(平均孕龄29.4周±5.5,范围17.6-39.3周;母亲年龄34.4岁±5.3,范围18.4-45.5岁),采用20分钟方案包括解剖T2加权快速自旋回波、定量T2*和扩散序列,由两名放射科医生和一名有MRI经验的产科医生评估双顶径、小脑横径、肺体积和宫颈长度等关键指标。
关键影像表现/征象
- 健康孕妇的关键解剖二维测量与大型横断面1.5T和3T对照研究一致。
- 前40次连续扫描中双顶径的观察者间相关性在异常组为0.96(95%CI:0.7,0.99;P=.002),在对照组为0.93(95%CI:0.86,0.97;P<.001)。
- 功能特征包括胎盘和脑T2*及胎盘表观扩散系数值与孕龄强相关,对照组胎盘T2*平均每周衰减5.2毫秒(R²=0.66),30周平均T2*为176.6毫秒(P<.001)。
诊断标准与关键数值
- 双顶径观察者间相关性:异常组0.96(95%CI:0.7,0.99;P=.002),对照组0.93(95%CI:0.86,0.97;P<.001)。
- 对照组胎盘T2*与孕龄线性回归:平均每周衰减5.2毫秒,R²=0.66,30周平均T2*为176.6毫秒,P<.001。
临床应用与阅片要点
- 20分钟0.55T低场强胎儿MRI方案可用于获取胎儿和胎盘的结构与功能测量,健康孕妇关键解剖测量与1.5T和3T对照研究一致。
- 双顶径在异常组和对照组的观察者间相关性分别为0.96和0.93,支持该指标在低场强下的重复测量可靠性。
- 胎盘和脑T2*及胎盘表观扩散系数值与孕龄强相关,可提供功能器官特异平均值的参考。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background The benefits of using low-field-strength fetal MRI to evaluate antenatal development include reduced image artifacts, increased comfort, larger bore size, and potentially reduced costs, but studies about fetal low-field-strength MRI are lacking. Purpose To evaluate the reliability and feasibility of low-field-strength fetal MRI to assess anatomic and functional measures in pregnant participants using a commercially available 0.55-T MRI scanner and a comprehensive 20-minute protocol. Materials and Methods This prospective study was performed at a large teaching hospital (St Thomas' Hospital; London, England) from May to November 2022 in healthy pregnant participants and participants with pregnancy-related abnormalities using a commercially available 0.55-T MRI scanner. A 20-minute protocol was acquired including anatomic T2-weighted fast-spin-echo, quantitative T2*, and diffusion sequences. Key measures like biparietal diameter, transcerebellar diameter, lung volume, and cervical length were evaluated by two radiologists and an MRI-experienced obstetrician. Functional organ-specific mean values were given. Comparison was performed with existing published values and higher-field MRI using linear regression, interobserver correlation, and Bland-Altman plots. Results A total of 79 fetal MRI examinations were performed (mean gestational age, 29.4 weeks ± 5.5 [SD] [age range, 17.6-39.3 weeks]; maternal age, 34.4 years ± 5.3 [age range, 18.4-45.5 years]) in 47 healthy pregnant participants (control participants) and in 32 participants with pregnancy-related abnormalities. The key anatomic two-dimensional measures for the 47 healthy participants agreed with large cross-sectional 1.5-T and 3-T control studies. The interobserver correlations for the biparietal diameter in the first 40 consecutive scans were 0.96 (95% CI: 0.7, 0.99; P = .002) for abnormalities and 0.93 (95% CI: 0.86, 0.97; P < .001) for control participants. Functional features, including placental and brain T2* and placental apparent diffusion coefficient values, strongly correlated with gestational age (mean placental T2* in the control participants: 5.2 msec of decay per week; R2 = 0.66; mean T2* at 30 weeks, 176.6 msec; P < .001). Conclusion The 20-minute low-field-strength fetal MRI examination protocol was capable of producing reliable structural and functional measures of the fetus and placenta in pregnancy. Clinical trial registration no. REC 21/LO/0742 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Gowland in this issue.