影像组学提高儿童低级别胶质瘤治疗前BRAF变异分型的置信度
研究基于临床与影像组学特征构建列线图,无创预测儿童低级别胶质瘤的BRAF状态。联合随机森林模型AUC为0.925,优于单独影像组学(0.863)或临床特征(0.889);线性模型AUC为0.916。双阈值法在80.7%高置信度患者中准确率达92.2%,传统单阈值法为84.5%。
要点
- 联合影像组学与临床特征的随机森林模型AUC达0.925,优于任一单独特征集。
- 双阈值法可识别模型预测不确定的病例,高置信度亚组准确率92.2%。
- 线性模型可转化为列线图,AUC为0.916,便于临床解释与实施。
核心结论
- 包含影像组学特征的模型表现更优,凸显其对BRAF状态预测的重要性;线性模型性能与随机森林相近且可可视化为列线图,双阈值技术能识别不确定预测,提升模型临床实用性。
研究设计与样本
- 研究在影像组学和临床特征上分别及联合训练随机森林模型,并训练线性模型以列线图呈现;采用双阈值机制替代传统单阈值将模型输出转为类别预测。
诊断标准与关键数值
- 联合随机森林模型AUC为0.925,高于单独影像组学随机森林的0.863和单独临床特征随机森林的0.889。
- 线性模型AUC为0.916,与随机森林模型性能相当。
- 传统阈值法准确率为84.5%。
- 双阈值法在80.7%的最高置信度预测患者中准确率为92.2%。
临床应用与阅片要点
- 影像组学特征与肿瘤位置均对儿童低级别胶质瘤患者的BRAF状态有预测价值,且二者包含互补信息。
- 最优模型以列线图呈现,可作为活检的无创替代方案。
- 双阈值法有助于区分机器学习模型预测很可能正确或错误的病例,提高模型实用性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Currently, the BRAF status of pediatric low-grade glioma (pLGG) patients is determined through a biopsy. We established a nomogram to predict BRAF status non-invasively using clinical and radiomic factors. Additionally, we assessed an advanced thresholding method to provide only high-confidence predictions for the molecular subtype. Finally, we tested whether radiomic features provide additional predictive information for this classification task, beyond that which is embedded in the location of the tumor.
METHODS: Random forest (RF) models were trained on radiomic and clinical features both separately and together, to evaluate the utility of each feature set. Instead of using the traditional single threshold technique to convert the model outputs to class predictions, we implemented a double threshold mechanism that accounted for uncertainty. Additionally, a linear model was trained and depicted graphically as a nomogram.
RESULTS: The combined RF (AUC: 0.925) outperformed the RFs trained on radiomic (AUC: 0.863) or clinical (AUC: 0.889) features alone. The linear model had a comparable AUC (0.916), despite its lower complexity. Traditional thresholding produced an accuracy of 84.5%, while the double threshold approach yielded 92.2% accuracy on the 80.7% of patients with the highest confidence predictions.
CONCLUSION: Models that included radiomic features outperformed, underscoring their importance for the prediction of BRAF status. A linear model performed similarly to RF but with the added benefit that it can be visualized as a nomogram, improving the explainability of the model. The double threshold technique was able to identify uncertain predictions, enhancing the clinical utility of the model.
CLINICAL RELEVANCE STATEMENT: Radiomic features and tumor location are both predictive of BRAF status in pLGG patients. We show that they contain complementary information and depict the optimal model as a nomogram, which can be used as a non-invasive alternative to biopsy.
KEY POINTS: • Radiomic features provide additional predictive information for the determination of the molecular subtype of pediatric low-grade gliomas patients, beyond what is embedded in the location of the tumor, which has an established relationship with genetic status. • An advanced thresholding method can help to distinguish cases where machine learning models have a high chance of being (in)correct, improving the utility of these models. • A simple linear model performs similarly to a more powerful random forest model at classifying the molecular subtype of pediatric low-grade gliomas but has the added benefit that it can be converted into a nomogram, which may facilitate clinical implementation by improving the explainability of the model.
引用
- Kudus K, Wagner MW, Namdar K, et al. Increased confidence of radiomics facilitating pretherapeutic differentiation of BRAF-altered pediatric low-grade glioma. Eur Radiol. 2023. PMID: 37803212. doi:10.1007/s00330-023-10267-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。