ASL术语与报告建议:ISMRM灌注成像开放科学倡议(OSIPI)共识报告
国际磁共振学会灌注研究组下属ASL术语工作组制定ASL术语与报告建议,覆盖(伪)连续ASL、脉冲ASL、速度选择性ASL及多时间点ASL的序列与参数,旨在统一术语并推荐论文中应报告的成像参数。
要点
- ASL术语共识覆盖(伪)连续、脉冲、速度选择性和多时间点ASL序列及参数。
- 建议作者在科学论文中报告ASL方法时纳入共识推荐的成像参数。
- 该术语内容不限于所列技术,将作为在线清单基础由社区扩展。
核心结论
- ASL术语工作组制定了标准化共识术语和报告建议,涵盖多种ASL技术及定量分析所需生理常数,并鼓励作者在论文中报告推荐的成像参数。
研究设计与样本
- ISMRM灌注研究组代表的ASL术语工作组制定共识报告,属于ISMRM灌注成像开放科学倡议(OSIPI)的一部分。
诊断标准与关键数值
- 纳入(伪)连续ASL、脉冲ASL、速度选择性ASL和多时间点ASL用于脑灌注成像的序列与参数。
- 术语内容不限于上述技术,将作为可扩展在线清单的基础。
临床应用与阅片要点
- 作者在科学报告或论文中描述ASL方法时,鼓励纳入共识推荐的成像参数。
局限性
- ASL领域快速发展,技术和相关术语进一步分化可能造成混淆并妨碍研究可重复性。
- 术语内容不限于本文所列技术,当前版本仅为在线清单的基础,将由社区扩展。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
The 2015 consensus statement published by the International Society for Magnetic Resonance in Medicine (ISMRM) Perfusion Study Group and the European Cooperation in Science and Technology ( COST) Action ASL in Dementia aimed to encourage the implementation of robust arterial spin labeling (ASL) perfusion MRI for clinical applications and promote consistency across scanner types, sites, and studies. Subsequently, the recommended 3D pseudo-continuous ASL sequence has been implemented by most major MRI manufacturers. However, ASL remains a rapidly and widely developing field, leading inevitably to further divergence of the technique and its associated terminology, which could cause confusion and hamper research reproducibility. On behalf of the ISMRM Perfusion Study Group, and as part of the ISMRM Open Science Initiative for Perfusion Imaging (OSIPI), the ASL Lexicon Task Force has been working on the development of an ASL Lexicon and Reporting Recommendations for perfusion imaging and analysis, aiming to (1) develop standardized, consensus nomenclature and terminology for the broad range of ASL imaging techniques and parameters, as well as for the physiological constants required for quantitative analysis; and (2) provide a community-endorsed recommendation of the imaging parameters that we encourage authors to include when describing ASL methods in scientific reports/papers. In this paper, the sequences and parameters in (pseudo-)continuous ASL, pulsed ASL, velocity-selective ASL, and multi-timepoint ASL for brain perfusion imaging are included. However, the content of the lexicon is not intended to be limited to these techniques, and this paper provides the foundation for a growing online inventory that will be extended by the community as further methods and improvements are developed and established.
引用
- Suzuki Y, Clement P, Dai W, et al. ASL lexicon and reporting recommendations: A consensus report from the ISMRM Open Science Initiative for Perfusion Imaging (OSIPI). Magn Reson Med. 2023. PMID: 37876299. doi:10.1002/mrm.29815
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。