有腹部症状的COVID-19患者的腹盆腔CT:包括两波疫情与对照组的读者一致性及共识复查后的过度诊断
回顾性纳入2020年3月15日至5月31日第一波116例和2020年11月1日至4月15日第二波194例有腹部症状的COVID-19患者及匹配的116例和194例疫情前对照,盲法判读腹盆腔CT并以共识解决分歧。COVID组读者一致性低于对照组(Cohen's Kappa 0.58 vs 0.82,p≤0.001),第一波低于第二波(0.45 vs 0.66,p=0.052);COVID组假阳性率高于对照组(OR=0.42,p=0.003),结肠炎和膀胱炎是最常见的过度诊断。
要点
- COVID-19患者腹盆腔CT的读者一致性低于疫情前对照(Kappa 0.58 vs 0.82,p≤0.001)。
- 第一波COVID-19病例的读者一致性低于第二波(Kappa 0.45 vs 0.66,p=0.052)。
- COVID-19组过度诊断以结肠炎和膀胱炎最常见。
核心结论
- COVID-19期间读者分歧大于疫情前,且初始读者和研究读者在COVID组中均报告更多假阳性,不存在读者偏倚;COVID期间过度诊断更多,结肠炎和膀胱炎最常见。
研究设计与样本
- 回顾性研究,纳入2020年3月15日至5月31日第一波116例和2020年11月1日至4月15日第二波194例有腹部症状的COVID-19患者,并匹配116例第一波和194例第二波疫情前对照;读者盲法判读腹盆腔CT,分歧病例经共识解决;用Cohen's Kappa测量读者一致性,置换检验比较队列差异,Fisher精确检验和逻辑回归分析假阳性/假阴性率影响因素。
诊断标准与关键数值
- 真阳性定义为初始读者与研究读者达成共识;COVID组读者一致性Cohen's Kappa 0.58 vs 对照组0.82(p≤0.001);第一波0.45 vs 第二波0.66(p=0.052);COVID组假阳性率高于对照组(OR=0.42,p=0.003);初始读者假阳性率高于研究读者(OR=0.36,p≤0.001);第二波假阳性率低于第一波(OR=0.5,p=0.028)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Since many COVID-19 publications lack consensus reviews or controls, interpretive accuracy is unclear; abdominal processes unique or infrequent during the pandemic remain unknown. The incidence and nature of CT findings accounting for abdominal complaints in COVID patients, reader agreement and overcalling will be determined.
METHODS: A retrospective study was performed on COVID patients with abdominal complaints from 3/15/2020-5/31/2020 and 11/1/2020-4/15/2021 including matched controls. Reviewers blinded to initial reads interpreted abdominopelvic CT exams, with discordant cases resolved in consensus. Reader agreement was measured by Cohen's Kappa, differences between cohorts by permutation tests and factors affecting false positive/negative rates by Fisher's Exact Test and logistic regression.
RESULTS: 116 first wave (average age 65 years [±15.3], 63 [54%] women) and 194 second wave COVID cases (average age 64 years [±16.3], 103 [53%] women) including 116 wave 1 and 194 wave 2 prepandemic controls were included. Concordance was lower among COVID cases than controls (Cohen's Kappa of 0.58 vs. 0.82 [p ≤ 0.001]) and among wave 1 than wave 2 cases (Cohen's Kappa of 0.45 vs. 0.66 [p = 0.052]). With true positives defined as consensus between the initial reader and study reader, false positive rates were higher among COVID cases than controls (OR = 0.42, p = 0.003) and for initial than study reader (OR = 0.36, p ≤ 0.001), but lower in wave 2 than 1 (OR = 0.5, p = 0.028).
CONCLUSION: Greater reader disagreement occurred during COVID than prepandemic with no reader bias as both initial and study readers called more false positives among COVID cases than controls. More overcalling occurred during COVID with colitis and cystitis most common.
引用
- Schechter MS, Kanmaniraja D, Berkenblit RG, et al. Abdominopelvic CT in COVID-19 patients with abdominal complaints including both waves and controls: reader agreement and overcalls after consensus review. Clin Imaging. 2023. PMID: 37845167. doi:10.1016/j.clinimag.2023.109988
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。