文献速递胸部腹部技术与安全CT

利用扫描仪集成的临床决策支持系统实现胸腹部CT检查的个性化:对采集技术、扫描范围和重建类型的影响

Personalization of thoracoabdominal CT examinations using scanner integrated clinical decision support systems - Impact on the acquisition technique, scan range, and reconstruction type.
PubMed 文献 · Eur J Radiol · 2023-09-01

本研究评估扫描仪集成的定制临床决策支持系统(CDSS)对胸腹部CT采集技术、扫描范围和重建的影响。在配备双能CT、解剖标志检测和迭代金属伪影减少功能的扫描仪上应用CDSS,回顾性比较624例研究扫描仪检查与740例无CDSS的对照扫描仪检查。CDSS使双能CT使用率从2.8%升至64.4%、金属伪影减少使用率从44.0%升至75.4%,双能CT主观图像质量与单能CT相当,但客观图像质量更高且有效剂量更低。

要点

  • CDSS使双能CT使用率从2.8%升至64.4%,金属伪影减少使用率从44.0%升至75.4%。
  • 双能CT扫描时间较单能CT延长(16.9秒 vs 6.5秒,p<0.001)。
  • 双能CT客观图像质量更高(CNRD 2.1 vs 1.8,p<0.01)且有效剂量更低(6.7 mSv vs 7.6 mSv,p=0.004)。

核心结论

  • 胸腹部CT的CDSS可大幅提高采集和重建中创新技术的使用率,采用适配方案的患者在更低辐射剂量下获益于图像质量改善和更多后处理选择。

研究设计与样本

  • 回顾性比较研究,研究组为配备CDSS的扫描仪上的624例检查,对照组为无CDSS的同类扫描仪上的740例检查,研究组行有效剂量、扫描时间和图像质量的亚组分析;研究扫描仪具备双能CT、解剖标志检测和迭代金属伪影减少功能。

关键影像表现/征象

  • 所有由解剖标志检测进行的扫描范围适配均成功。
  • 单能CT与双能CT采集的主观图像质量相当(所有p>0.05)。
  • 双能CT的客观图像质量显著高于单能CT(CNRD 2.1 vs 1.8;p<0.01)。

诊断标准与关键数值

  • CDSS根据定位像后回答的屏气能力、解剖兴趣区和金属植入物问题,自动适配采集技术(单能或双能)、扫描范围(胸-腹-盆或胸-腹)和重建技术(是否使用金属伪影减少)。
  • 双能CT使用率64.4% vs 2.8%,金属伪影减少使用率75.4% vs 44.0%。
  • 双能CT扫描时间16.9秒 vs 单能CT 6.5秒(p<0.001)。
  • 双能CT有效剂量6.7 mSv vs 单能CT 7.6 mSv(p=0.004)。

临床应用与阅片要点

  • CDSS可在定位像后根据患者屏气能力、兴趣区和金属植入物自动适配采集技术、扫描范围与重建方式。
  • 解剖标志检测可成功完成扫描范围适配。
  • 双能CT虽延长扫描时间,但可提高客观图像质量并降低有效剂量。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study evaluates the impact of a scanner-integrated, customized clinical decision support system (CDSS) on the acquisition technique, scan range, and reconstruction in thoracoabdominal CT.

MATERIALS AND METHODS: We applied CDSS in contrast-enhanced examinations of the trunk with various clinical indications on a recent scanner with the capability of dual-energy CT (DECT), anatomic landmark detection (ALD), and iterative metal-artifact reduction (MAR). Simple and comprehensive questions about the patient's breath hold capability, the anatomical region of interest, and metal implants can be answered after the localizer. The acquisition technique (single energy, SECT, or dual energy), scan range (chest-abdomen-pelvis or chest-abdomen), and reconstruction technique (with or without MAR) were then automatically adapted in the examination protocols in coherence with these selections. Retrospectively, we compared the usage rates for these techniques in 624 examinations on the study scanner with 740 examinations on a comparable scanner without CDSS. Subgroup analysis of effective dose (ED), scan duration, and image quality (IQ) was performed in the study group.

RESULTS: CDSS leads to an increased usage rate of DECT (64.4% vs. 2.8%) and MAR (75.4% vs. 44.0%). All scan range adaptations by ALD were successful. The resulting subjective IQ between single energy and DECT acquisitions was comparable (all p > 0.05). Scan duration was significantly longer in DECT than in SECT (16.9 s vs. 6.5 s; p < 0.001). However, the objective IQ was significantly higher in DECT (CNRD 2.1 vs. 1.8; p < 0.01), and the ED significantly lower (6.7 mSv vs. 7.6 mSv; p = 0.004).

CONCLUSION: CDSS for thoracoabdominal CT leads to a substantially increased usage rate of innovative techniques during acquisition and reconstruction. Patients with adapted protocols benefit from improved image quality and increased post-processing options at lower radiation doses.