文献速递神经MR

基于T2-FLAIR图像的海马放射组学模型在内侧颞叶癫痫伴海马硬化中的诊断性能

Performance of hippocampal radiomics models based on T2-FLAIR images in mesial temporal lobe epilepsy with hippocampal sclerosis.
PubMed 文献 · Eur J Radiol · 2023-09-09

本研究分析210例受试者(172例病理确诊海马硬化的内侧颞叶癫痫患者,其中MRI阳性100例、MRI阴性72例,以及38例健康对照),基于T2-FLAIR序列构建海马放射组学逻辑回归模型。模型在MRI阴性海马硬化与健康对照、MRI阳性海马硬化与健康对照、内侧颞叶癫痫与健康对照的比较中AUC均大于0.85,提示基于T2-FLAIR图像的海马放射组学模型有助于诊断内侧颞叶癫痫伴海马硬化。

要点

  • MRI阳性海马硬化与健康对照的模型诊断效能最高,训练集AUC 0.975、测试集AUC 0.954。
  • MRI阴性海马硬化与健康对照的模型训练集AUC 0.863、测试集AUC 0.855。
  • 内侧颞叶癫痫与健康对照的模型训练集AUC 0.912、测试集AUC 0.854。

核心结论

  • 基于T2-FLAIR图像的海马放射组学模型可帮助诊断内侧颞叶癫痫伴海马硬化。
  • 该模型可作为内侧颞叶癫痫诊断的生物学标志物。

研究设计与样本

  • 研究类型为诊断性研究,共分析210例,包括172例病理确诊海马硬化的内侧颞叶癫痫患者(MRI阳性海马硬化100例、MRI阴性海马硬化72例)和38例健康对照。
  • 在斜冠状面上沿垂直于海马长轴的T2-FLAIR序列逐层勾画海马,获得三维感兴趣区。
  • 使用人工智能工具包软件处理放射组学特征,构建逻辑回归放射组学模型,模型评价指标包括AUC、准确率、敏感度和特异度。

诊断标准与关键数值

  • MRI阴性海马硬化与健康对照:训练集AUC 0.863、准确率81.4%、敏感度78.0%、特异度84.6%;测试集AUC 0.855、准确率75.0%、敏感度68.2%、特异度81.8%。
  • MRI阳性海马硬化与健康对照:训练集AUC 0.975、准确率95.0%、敏感度92.9%、特异度98.0%;测试集AUC 0.954、准确率88.7%、敏感度90.0%、特异度87.0%。
  • 内侧颞叶癫痫与健康对照:训练集AUC 0.912、准确率84.3%、敏感度83.3%、特异度86.5%;测试集AUC 0.854、准确率79.7%、敏感度80.8%、特异度77.3%。
  • 各比较组放射组学模型的AUC值均大于0.85,提示诊断效能良好。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Preoperative identification of hippocampal sclerosis (HS) is crucial to successful surgery for mesial temporal lobe epilepsy (MTLE). We aimed to investigate the diagnostic performance of hippocampal radiomics models based on T2 fluid-attenuated inversion recovery (FLAIR) images in MTLE with HS.

METHODS: We analysed 210 cases, including 172 HS pathology-confirmed cases (100 magnetic resonance imaging [MRI]-positive cases [MRI + HS], 72 MRI-negative HS cases [MRI - HS]), and 38 healthy controls (HC). The hippocampus was delineated slice by slice on an oblique coronal plane by a T2-FLAIR sequence, perpendicular to the hippocampus's long axis, to obtain a three-dimensional region of interest. Radiomics were processed using Artificial Intelligence Kit software; logistic regression radiomics models were constructed. The model evaluation indexes included the area under the curve (AUC), accuracy, sensitivity, and specificity.

RESULTS: The respective AUC, accuracy, sensitivity, and specificity were 0.863, 81.4%, 78.0%, and 84.6% between the MRI - HS and HC groups in the training set and 0.855, 75.0%, 68.2%, and 81.8% in the test set; 0.975, 95.0%, 92.9%, and 98.0% between the MRI + HS and HC groups in the training set and 0.954, 88.7%, 90.0%, and 87.0% in the test set; and 0.912, 84.3%, 83.3%, and 86.5% between the MTLE and HC groups in the training set and 0.854, 79.7%, 80.8%, and 77.3% in the test set. The AUC values of the comparative radiomics models were > 0.85, indicating good diagnostic efficiency.

CONCLUSION: The hippocampal radiomics models based on T2-FLAIR images can help diagnose MTLE with HS. They can be used as biological markers for MTLE diagnosis.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Wang X, Luo X, Pan H, et al. Performance of hippocampal radiomics models based on T2-FLAIR images in mesial temporal lobe epilepsy with hippocampal sclerosis. Eur J Radiol. 2023. PMID: 37708677. doi:10.1016/j.ejrad.2023.111082

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。