基于深度学习的胸部低剂量CT无体模内校准自动测量椎体骨密度

Automated vertebral bone mineral density measurement with phantomless internal calibration in chest LDCT scans using deep learning.
PubMed 文献 · Br J Radiol · 2023-10-24

本研究纳入1175例同时行胸部低剂量CT和定量CT骨密度检查者,用两个卷积神经网络分割和标记椎体,以椎旁肌和脂肪为参考通过直方图技术计算骨密度。所提方法与定量CT的骨密度强相关,但一致性不足以互换使用;调整截断值后骨质疏松和低骨密度诊断AUC在两组验证队列均升至0.920以上。

要点

  • 所提方法自动测量椎体骨密度与定量CT强相关,验证队列I r=0.896、验证队列II r=0.956。
  • 验证队列I中Bland-Altman平均差异1.1 mg/cm3,95%一致性界限宽达-29.9至+32.0 mg/cm3。
  • 调整截断值后,骨质疏松和低骨密度诊断AUC在两个验证队列均升至0.920以上。

核心结论

  • 无需手动勾画体组织感兴趣区,基于深度学习和无体模内校准的方法有潜力用于胸部低剂量CT对低骨密度患者的初步筛查,但其与定量CT的一致性不足以在骨密度测量中互换使用。

研究设计与样本

  • 共纳入1175例同时行胸部低剂量CT和定量CT骨密度检查者,使用Siemens和GE两台不同CT扫描仪;两个卷积神经网络分别用于椎体分割和标记;以椎旁肌和周围脂肪为参考,用直方图技术计算椎体骨密度;195例Siemens扫描者作为拟合队列建立校准函数,698例Siemens扫描者作为验证队列I、282例GE扫描者作为验证队列II评估所提方法性能,以定量CT为标准进行分析。

诊断标准与关键数值

  • 所提方法平均骨密度与定量CT强相关(验证队列I r=0.896,验证队列II r=0.956,p<0.001);验证队列I中Bland-Altman平均差异1.1 mg/cm3,95%一致性界限-29.9至+32.0 mg/cm3;验证队列II中所提方法测得的骨密度高于定量CT(平均差异=15.3 mg/cm3,p<0.001);所提方法诊断骨质疏松和低骨密度的AUC在验证队列I分别为0.876和0.903,在验证队列II分别为0.731和0.794;调整截断值后,两个验证队列的AUC均升至0.920以上。

临床应用与阅片要点

  • 所提方法可在不手动选择体组织感兴趣区的情况下自动测量椎体骨密度,有潜力用于胸部低剂量CT对低骨密度患者的初步筛查;但所提方法与定量CT的一致性不足以在骨密度测量中互换使用。

局限性

  • 所提方法与定量CT的一致性不足以在骨密度测量中互换使用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To develop and evaluate a fully automated method based on deep learning and phantomless internal calibration for bone mineral density (BMD) measurement and opportunistic low BMD (osteopenia and osteoporosis) screening using chest low-dose CT (LDCT) scans.

METHODS: A total of 1175 individuals were enrolled in this study, who underwent both chest LDCT and BMD examinations with quantitative computed tomography (QCT), by two different CT scanners (Siemens and GE). Two convolutional neural network (CNN) models were employed for vertebral body segmentation and labeling, respectively. A histogram technique was applied for vertebral BMD calculation using paraspinal muscle and surrounding fat as references. 195 cases (by Siemens scanner) as fitting cohort were used to build the calibration function. 698 cases as validation cohort I (VCI, by Siemens scanner) and 282 cases as validation cohort II (VCII, by GE scanner) were performed to evaluate the performance of the proposed method, with QCT as the standard for analysis.

RESULTS: The average BMDs from the proposed method were strongly correlated with QCT (in VCI: r = 0.896, in VCII: r = 0.956, p < 0.001). Bland-Altman analysis showed a small mean difference of 1.1 mg/cm3, and large interindividual differences as seen by wide 95% limits of agreement (-29.9 to +32.0 mg/cm3) in VCI. The proposed method measured BMDs were higher than QCT measured BMDs in VCII (mean difference = 15.3 mg/cm3, p < 0.001). Osteoporosis and low BMD were diagnosed by proposed method with AUCs of 0.876 and 0.903 in VCI, 0.731 and 0.794 in VCII, respectively. The AUCs of the proposed method were increased to over 0.920 in both VCI and VCII after adjusting the cut-off.

CONCLUSION: Without manual selection of the region of interest of body tissues, the proposed method based on deep learning and phantomless internal calibration has the potential for preliminary screening of patients with low BMD using chest LDCT scans. However, the agreement between the proposed method and QCT is insufficient to allow them to be used interchangeably in BMD measurement.

ADVANCES IN KNOWLEDGE: This study proposed an automated vertebral BMD measurement method based on deep learning and phantomless internal calibration with paraspinal muscle and fat as reference.