虚拟3D股骨模型评估股骨前倾角:与2D轴位切片方法的比较

Virtual 3D femur model to assess femoral version: comparison to the 2D axial slice approach.
PubMed 文献 · Pediatr Radiol · 2023-09-23

本研究在71例儿童(142根股骨)中比较虚拟3D股骨模型与Murphy 2D轴位切片法测量股骨前倾角的可靠性。两种技术组内与组间ICC均≥0.91,但Bland-Altman分析显示Murphy法两阅片者绝对差值的标准差(均值13.7°)大于3D模型法(均值4.8°),在髋屈曲畸形和明显髋外翻畸形股骨中3D模型法变异更小。

要点

  • 虚拟3D股骨模型测量股骨前倾角的阅片者间变异小于Murphy 2D轴位切片法。
  • 髋屈曲畸形股骨中Murphy法绝对差值SD为17°,3D模型法为6.5°。
  • 明显髋外翻畸形股骨中Murphy法绝对差值SD为10.4°,3D模型法为5.2°。

核心结论

  • 3D股骨模型技术测量股骨前倾角比Murphy 2D轴位切片技术更可靠,尤其在髋屈曲和明显髋外翻畸形的儿童中。

研究设计与样本

  • 回顾性影像数据库研究,纳入2021年9月至2022年8月临床指征为股骨前倾角测量的儿童(<18岁)髋/股骨CT,排除既往髋部手术及图像质量或视野不合格者,最终样本为71例患者共142根股骨(年龄10.6±4.4岁,男性31例)。

诊断标准与关键数值

  • 两种技术组内与组间ICC均≥0.91;Murphy法两阅片者绝对差值均值13.7°,3D股骨模型法为4.8°;髋屈曲畸形股骨中Murphy法绝对差值SD为17°、3D模型法为6.5°;明显髋外翻畸形股骨中Murphy法绝对差值SD为10.4°、3D模型法为5.2°。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Quantifying femoral version is crucial in diagnosing femoral version abnormalities and for accurate pre-surgical planning. There are numerous methods for measuring femoral version, however, reliability studies for most of these methods excluded children with hip deformities.

OBJECTIVE: To propose a method of measuring femoral version based on a virtual 3D femur model, and systematically compare its reliability to the widely used Murphy's 2D axial slice technique.

MATERIALS AND METHODS: We searched our imaging database to identify hip/femur CTs performed on children (<18 years old) with a clinical indication of femoral version measurement (September 2021-August 2022). Exclusion criteria were prior hip surgery, and inadequate image quality or field-of-view. Two blinded radiologists independently measured femoral version using the virtual 3D femur model and Murphy's 2D axial slice method. To assess intrareader variability, we randomly selected 20% of the study sample for re-measurements by the two radiologists >2 weeks later. We analyzed the reliability and correlation of these techniques via intraclass correlation coefficient (ICC), Bland-Altman analysis, and deformity subgroup analysis.

RESULTS: Our study sample consisted of 142 femurs from 71 patients (10.6±4.4 years, male=31). Intra- and inter-reader correlations for both techniques were excellent (ICC≥0.91). However, Bland-Altman analysis revealed that the standard deviation (SD) of the absolute difference between the two radiologists for the Murphy method (mean 13.7°) was larger than that of the 3D femur model technique (mean 4.8°), indicating higher reader variability. In femurs with hip flexion deformity, the SD of the absolute difference for the Murphy technique was 17°, compared to 6.5° for the 3D femur model technique. In femurs with apparent coxa valga deformity, the SD of the absolute difference for the Murphy technique was 10.4°, compared to 5.2° for the 3D femur model technique.

CONCLUSION: The 3D femur model technique is more reliable than the Murphy's 2D axial slice technique in measuring femoral version, especially in children with hip flexion and apparent coxa valga deformities.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Iwasaka-Neder J, Bixby SD, Bedoya MA, et al. Virtual 3D femur model to assess femoral version: comparison to the 2D axial slice approach. Pediatr Radiol. 2023. PMID: 37740782. doi:10.1007/s00247-023-05758-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。