基于中国全国性调查的儿科CT检查剂量结果与分析

Results and analysis of examination doses for paediatric CT procedures based on a nationwide survey in China.
PubMed 文献 · Eur Radiol · 2023-09-06

基于2017至2018年中国大陆31省的调查,纳入262家医院、319台CT设备和24395例儿科患者,按4个年龄组和3种检查程序(头部、胸部、腹部)计算CTDIvol与DLP的中位数和75百分位数,首次提出中国儿科CT的国家诊断参考水平。结果显示中国儿科CT剂量与部分亚洲国家相近但高于欧洲国家,检查参数和剂量需进一步优化,尤其应降低管电压。

要点

  • 首次提出中国大陆儿科CT头部、胸部、腹部3种程序及4个年龄组的国家诊断参考水平。
  • 国家DRL基于各CT设备中位剂量的75百分位数分布估算。
  • 中国儿科CT剂量与部分亚洲国家相近但高于欧洲国家,检查参数和剂量需进一步优化。

核心结论

  • 首次报告中国大陆儿童CT扫描的剂量水平,所提出的儿科CT诊断参考水平与部分亚洲国家相近但高于欧洲国家。

研究设计与样本

  • 2017至2018年在中国大陆31个省份开展全国性剂量调查,每家医院每个年龄组和每种检查程序至少选取10例患者。
  • 共调查262家医院、319台CT设备和24395例儿科患者。
  • 从HIS或RIS-PACS系统收集CTDIvol和DLP剂量信息,以每台CT设备的中位值作为该设备儿科患者的代表性剂量值。
  • 国家诊断参考水平基于各设备中位值的75百分位数分布估算。

诊断标准与关键数值

  • 对4个年龄组(0-<1、1-<5、5-<10、10-<15岁)和3种检查程序(头部、胸部、腹部)分别计算CTDIvol和DLP的中位数(P50)及75百分位数(P75)。
  • 基于上述P75分布提出每种检查程序和每个年龄组的国家诊断参考水平。

临床应用与阅片要点

  • 儿科CT广泛用于儿科疾病诊断,但儿童对辐射更敏感,建立儿科CT检查的诊断参考水平对降低儿童CT剂量和促进医疗照射优化是必要的。
  • 中国儿科CT的检查参数和剂量需进一步优化,尤其应降低儿科CT的管电压。

局限性

  • 中国儿科CT的检查参数和剂量需进一步优化,尤其应降低儿科CT的管电压。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To report the results of a dose survey conducted across 31 provinces in mainland China from 2017 to 2018 and to analyse the dose level to determine the national diagnostic reference levels (DRLs) for paediatric CT procedures.

METHODS: At least ten patients for each age group (0- < 1, 1- < 5, 5- < 10, 10- < 15 years) and each procedure (head, chest and abdomen) for each CT scanner were selected from four to eight hospitals in each province. The dose information (CTDIvol and DLP) was collected from the HIS or RIS-PACS systems. The median values in each CT scanner were considered the representative dose values for the paediatric patients in CT scanning. The national DRLs were estimated based on the 75th percentile distribution of the median values.

RESULTS: A total of 24,395 patients and 319 CT scanners were investigated across 262 hospitals. For paediatric CT scanning in 4 different age groups, the median (P50) and the 75th percentile (P75) of CTDIvol and DLP for each scanning procedure were calculated and reported. National DRLs were then proposed for each procedure and age group.

CONCLUSION: The dose level of CT scanning for children in mainland China was reported for the first time. The DRLs for paediatric CT in the present study are similar to those in some Asian countries but higher than those in European countries.

CLINICAL RELEVANCE STATEMENT: The paediatric CT is an extensively used tool in diagnosing paediatric disease; however, children are more sensitive to radiation. Establishing the diagnostic reference level of paediatric CT examination is necessary to reduce the dose of CT in children and promote the optimisation of medical exposure.

KEY POINTS: • The DRLs for 3 paediatric CT procedures (head, chest and abdomen) and 4 age groups (0- < 1, 1- < 5, 5- < 10, 10- < 15 years) were proposed in mainland China first time. • The examination parameter and dose for children need to be further optimised in China, especially to lower the tube voltage in paediatric CT.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Xu H, Sun QF, Yue BR, et al. Results and analysis of examination doses for paediatric CT procedures based on a nationwide survey in China. Eur Radiol. 2023. PMID: 37672054. doi:10.1007/s00330-023-10005-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。