颈动脉斑块影像组学:系统综述与影像组学质量评分评估
该系统综述纳入16项研究共2429例患者,评估基于影像组学数据的机器学习模型对颈动脉斑块的分类或预测效能,模型平均AUC为0.88±0.02(范围0.741-0.989),平均RQS为9.25(标准差6.04),仅占满分36的25.7%,提示影像组学报告的方法学质量仍处于初期阶段。
要点
- 颈动脉斑块影像组学模型的平均AUC为0.88±0.02,范围0.741-0.989。
- 纳入研究的平均RQS为9.25(标准差6.04),仅占满分36的25.7%。
- RQS最低分为-2分,最高分为22分。
核心结论
- 影像组学模型可为颈动脉斑块患者提供额外信息,但影像组学报告的方法学质量仍处于初期阶段,许多障碍尚待克服。
研究设计与样本
- 系统综述,检索PubMed和Cochrane图书馆2001年1月1日至2022年9月30日发表的回顾性和前瞻性研究,纳入开发或验证基于影像组学数据的机器学习模型以分类或预测颈动脉斑块的研究,共16项研究2429例患者;由两名研究者独立审阅,采用影像组学质量评分(RQS)工具评估方法学质量,采用诊断准确性研究质量评估-2(QUADAS-2)评估偏倚风险。
诊断标准与关键数值
- 影像组学模型对颈动脉斑块诊断或预测性能的平均AUC为0.88±0.02,范围为0.741-0.989。
- 纳入研究的平均RQS为9.25(标准差6.04),占满分36的25.7%,最低分为-2分,最高分为22分。
局限性
- 影像组学报告的方法学质量仍处于初期阶段,许多障碍尚待克服。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Imaging modalities provide information on plaque morphology and vulnerability; however, they are operator dependent and miss a great deal of microscopic information. Recently, many radiomics models for carotid plaque that identify unstable plaques and predict cardiovascular outcomes have been proposed. This systematic review was aimed at assessing whether radiomics is a reliable and reproducible method for the clinical prediction of carotid plaque. A systematic search was conducted to identify studies published in PubMed and Cochrane library from January 1, 2001, to September 30, 2022. Both retrospective and prospective studies that developed and/or validated machine learning models based on radiomics data to classify or predict carotid plaques were included. The general characteristics of each included study were selected, and the methodological quality of radiomics reports and risk of bias were evaluated using the radiomics quality score (RQS) tool and Quality Assessment of Diagnostic Accuracy Studies-2, respectively. Two investigators independently reviewed each study, and the consensus data were used for analysis. A total of 2429 patients from 16 studies were included. The mean area under the curve of radiomics models for diagnostic or predictive performance of the included studies was 0.88 ± 0.02, with a range of 0.741-0.989. The mean RQS was 9.25 (standard deviation: 6.04), representing 25.7% of the possible maximum value of 36, whereas the lowest point was -2, and the highest score was 22. Radiomics models have revealed additional information on patients with carotid plaque, but with respect to methodological quality, radiomics reports are still in their infancy, and many hurdles need to be overcome.
引用
- Hou C, Liu XY, Du Y, et al. Radiomics in Carotid Plaque: A Systematic Review and Radiomics Quality Score Assessment. Ultrasound Med Biol. 2023. PMID: 37718124. doi:10.1016/j.ultrasmedbio.2023.06.008
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。