文献速递骨肌技术与安全US

超声散斑追踪测量手指屈肌腱修复术后肌腱滑动的效度验证

Validation of the Efficacy of Ultrasound Speckle Tracking in Measuring Tendon Gliding After Finger Flexor Tendon Repair.
PubMed 文献 · Ultrasound Med Biol · 2023-09-22

本研究先在离体猪屈肌腱单轴拉伸实验和人体手指屈肌腱等长收缩实验中验证基于二维射频信号的超声散斑追踪算法(UST),再将其用于手指屈肌腱修复术后患者,比较患侧与健侧肌腱滑动并分析其与关节活动度的相关性。UST与离体实验结果一致性极佳(平均R²=0.98),重测信度ICC=0.90;患侧滑动量(p=0.001)和主动关节活动度(p=0.002)均小于健侧,肌腱滑动与被动关节活动度的显著相关仅见于健侧(ρ=0.711,p=0.009)。

要点

  • UST与离体拉伸实验一致性高(平均R²=0.98),重测信度ICC=0.90。
  • 手指屈肌腱修复术后患侧肌腱滑动量小于健侧(p=0.001)。
  • 患侧主动关节活动度小于健侧(p=0.002)。

核心结论

  • 本研究提供了一种经验证的UST方案,可量化手指屈肌腱滑动以评估术后肌腱恢复;不同关节活动度受限程度患者的肌腱滑动有待进一步探索,以对肌腱粘连严重程度进行分级。

研究设计与样本

  • 先以离体猪屈肌腱单轴拉伸实验和人体手指屈肌腱等长收缩实验验证基于二维射频信号的超声散斑追踪算法(UST),再将验证后的UST应用于手指屈肌腱修复术后患者,比较患侧与健侧肌腱滑动并分析其与关节活动度的相关性。

关键影像表现/征象

  • UST与离体拉伸实验结果的平均R²值为0.98,平均绝对误差为0.15±0.08 mm,平均绝对百分比误差为5.19±2.43%。
  • 重测信度ICC为0.90,一致性良好。
  • 患侧肌腱滑动量小于健侧(p=0.001)。
  • 患侧主动关节活动度小于健侧(p=0.002)。
  • 肌腱滑动与被动关节活动度的显著相关仅见于健侧(ρ=0.711,p=0.009)。

诊断标准与关键数值

  • UST效度验证:与离体拉伸实验相比,平均R²=0.98,平均绝对误差0.15±0.08 mm,平均绝对百分比误差5.19±2.43%。
  • 重测信度:ICC=0.90。
  • 患侧与健侧比较:肌腱滑动p=0.001,主动关节活动度p=0.002。
  • 健侧肌腱滑动与被动关节活动度相关:ρ=0.711,p=0.009。

临床应用与阅片要点

  • UST可用于定量评估手指屈肌腱修复术后肌腱滑动,辅助判断术后肌腱恢复情况。
  • 患侧肌腱滑动量和主动关节活动度均低于健侧,阅片时可关注患侧滑动受限表现。
  • 肌腱滑动与被动关节活动度的显著相关仅在健侧观察到,患侧未发现此相关。

局限性

  • 手指屈肌腱滑动在不同关节活动度受限程度患者中尚需进一步探索,以对肌腱粘连严重程度进行分级。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Restricted tendon gliding is commonly observed in patients after finger flexor tendon (FFT) repair. The study described here was aimed at quantifying the amount of FFT gliding to evaluate the recovery of post-operative tendons using a 2-D radiofrequency (RF)-based ultrasound speckle tracking algorithm (UST).

METHODS: Ex vivo uniaxial tensile testing of porcine flexor tendons and in vivo isometric testing of human FFT were implemented to verify the efficacy of UST beforehand. The verified UST was then applied to the patients after FFT repair to compare tendon gliding between affected and healthy sides and to investigate its correlation with the joint range of motion (ROM).

RESULTS: Excellent validity was confirmed with the average R2 value of 0.98, mean absolute error of 0.15 ± 0.08 mm and mean absolute percentage error of 5.19 ± 2.43% between results from UST and ex vivo testing. The test-retest reliability was verified with good agreement of ICC (0.90). The affected side exhibited less gliding (p = 0.001) and smaller active ROM (p = 0.002) than the healthy side. Meanwhile, a significant correlation between tendon gliding and passive ROM was found only on the healthy side (ρ = 0.711, p = 0.009).

CONCLUSION: The present study provides a promising protocol to evaluate post-operative tendon recovery by quantifying the amount of FFT gliding with a validated UST. FFT gliding in patients with different levels of ROM restriction should be further explored for categorizing the severity of tendon adhesion.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Wang MW, Lee WN, Hung CC, et al. Validation of the Efficacy of Ultrasound Speckle Tracking in Measuring Tendon Gliding After Finger Flexor Tendon Repair. Ultrasound Med Biol. 2023. PMID: 37741741. doi:10.1016/j.ultrasmedbio.2023.08.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。