文献速递骨肌DRCT

深度学习在肩关节前后位X线片上自动测量临界肩角相关肩峰形态参数

Deep learning for automated measurement of CSA related acromion morphological parameters on anteroposterior radiographs.
PubMed 文献 · Eur J Radiol · 2023-09-09

本研究回顾性纳入2018至2020年本机构的120例连续CT扫描生成的1080张数字重建放射图像(DRR)和159张X线片,开发并验证了全自动测量临界肩角相关肩峰形态参数(CSA-RAMP)的深度学习算法。算法分割性能平均精度(AP)为57.67、AP50为94.31;在两个测试数据集中,全自动、半自动与手动测量间均呈强相关(数据集I r=0.990–0.997,数据集II r=0.984–0.995,均P<0.001)。Bland-Altman分析显示除CD外所有CSA-RAMP测量偏倚均较低,CD最大偏倚为2.49%。

要点

  • 全自动深度学习算法可在肩关节前后位X线片上快速测量CSA-RAMP。
  • 全自动与手动、半自动测量间呈强相关(r≥0.984,P<0.001)。
  • 除CD外各参数Bland-Altman偏倚低,CD最大偏倚2.49%。

核心结论

  • 成功开发了能快速、准确测量肩关节前后位X线片上CSA-RAMP的全自动算法,一致的自动测量系统可能加速未来大型肩袖撕裂患者队列的疾病生物学研究。

研究设计与样本

  • 回顾性分析2018至2020年本机构CT扫描和X线检查的影像;用每例CT生成的数字重建放射图像(DRR)开发系统;在数据集I(DRR)和数据集II(X线片)两个独立测试集上与手动和半自动测量比较;共纳入120例连续CT扫描生成的1080张DRR和159张X线片。

诊断标准与关键数值

  • 分割性能平均精度(AP)57.67、AP50 94.31;数据集I全自动vs手动、全自动vs半自动、半自动vs手动CSA-RAMP测量r=0.990–0.997(P<0.001);数据集II r=0.984–0.995(P<0.001);Bland-Altman分析数据集I和II除CD外所有CSA-RAMP测量偏倚低,CD最大偏倚2.49%。

临床应用与阅片要点

  • 作者认为全自动CSA-RAMP测量系统可能加速未来大型肩袖撕裂患者队列的疾病生物学研究。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: The Critical Shoulder Angle Related Acromion Morphological Parameter (CSA- RAMP) is a valuable tool in the analyzing the etiology of the rotator cuff tears (RCTs). However, its clinical application has been limited by the time-consuming and prone to inter- and intra-user variability of the measurement process.

OBJECTIVES: To develop and validate a deep learning algorithm for fully automated assessment of shoulder anteroposterior radiographs associated with RCTs and calculation of CSA-RAMP.

METHODS: Retrospective analysis was conducted on radiographs obtained from computed tomography (CT) scans and X-rays performed between 2018 and 2020 at our institution. The development of the system involved the utilization of digitally reconstructed radiographs (DRRs) generated from each CT scan. The system's performance was evaluated by comparing it with manual and semiautomated measurements on two separate test datasets: dataset I (DRRs) and dataset II (X-rays). Standard metrics, including mean average precision (AP), were utilized to assess the segmentation performance. Additionally, the consistency among fully automated, semiautomated, and manual measurements was comprehensively evaluated using the Pearson correlation coefficient and Bland-Altman analysis.

RESULTS: A total of 1080 DRRs generated from 120 consecutive CT scans and 159 X-ray films were included in the study. The algorithm demonstrated excellent segmentation performance, with a mean AP of 57.67 and an AP50 of 94.31. Strong inter-group correlations were observed for all CSA-RAMP measurements in both test datasets I (automated versus manual, automated versus semiautomated, and semiautomated versus manual; r = [0.990---0.997], P < 0.001) and dataset II (r = [0.984---0.995], P < 0.001). Bland-Altman analysis revealed low bias for all CSA-RAMP measurements in both test datasets I and II, except for CD (with a maximum bias of 2.49%).

CONCLUSIONS: We have successfully developed a fully automated algorithm capable of rapidly and accurately measuring CSA-RAMP on shoulder anteroposterior radiographs. A consistent automated CSA- RAMP measurement system may accelerate powerful and precise studies of disease biology in future large cohorts of RCTs patients.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Alike Y, Li C, Hou J, et al. Deep learning for automated measurement of CSA related acromion morphological parameters on anteroposterior radiographs. Eur J Radiol. 2023. PMID: 37714046. doi:10.1016/j.ejrad.2023.111083

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。