文献速递骨肌MR

人髌骨软骨的T1rho磁共振特性:与压痕硬度及生化成分的相关性

T1rho MR properties of human patellar cartilage: correlation with indentation stiffness and biochemical contents.
PubMed 文献 · Skeletal Radiol · 2023-09-23

研究对5例中度退变尸体的髌骨软骨行3T螺旋斩波磁化准备T1rho序列成像,并行压痕测试与生化分析。高T1rho值与低压痕硬度相关,且与含水量正相关、与糖胺聚糖含量负相关,多变量相关性强于单变量。

要点

  • 高T1rho值区域对应软骨表面退变(粗糙、侵蚀)及低压痕硬度。
  • T1rho值与含水量正相关(R²=0.10,p<0.05),与GAG含量负相关(R²=0.13,p<0.01)。
  • 多变量相关(R²=0.23,p<0.01)强于任一单变量相关。

核心结论

  • T1rho值对软骨空间功能与成分变化敏感,相关性强度取决于数据分析方法和多变量考量。

研究设计与样本

  • 离体研究,5例供体单侧膝关节中度退变髌骨,3T螺旋斩波磁化准备T1rho序列成像,参考标准为压痕测试及生化分析(水与硫酸化糖胺聚糖含量)。

关键影像表现/征象

  • 大体软骨表面退变(质地粗糙和侵蚀)对应高T1rho值区域。
  • 高T1rho值与低压痕硬度相关,相关强度随ROI大小略有变化。

诊断标准与关键数值

  • T1rho值与水含量空间变化正相关(R²=0.10,p<0.05)。
  • T1rho值与GAG含量空间变化负相关(R²=0.13,p<0.01)。
  • 多变量相关R²=0.23,p<0.01。

临床应用与阅片要点

  • 作者认为T1rho值可敏感反映软骨空间功能与成分变化。
  • 作者指出相关性强度取决于数据分析方法及多变量考量。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Cartilage degeneration involves structural, compositional, and biomechanical alterations that may be detected non-invasively using quantitative MRI. The goal of this study was to determine if topographical variation in T1rho values correlates with indentation stiffness and biochemical contents of human patellar cartilage.

DESIGN: Cadaveric patellae from unilateral knees of 5 donors with moderate degeneration were imaged at 3-Telsa with spiral chopped magnetization preparation T1rho sequence. Indentation testing was performed, followed by biochemical analyses to determine water and sulfated glycosaminoglycan contents. T1rho values were compared to indentation stiffness, using semi-circular regions of interest (ROIs) of varying sizes at each indentation site. ROIs matching the resected tissues were analyzed, and univariate and multivariate regression analyses were performed to compare T1rho values to biochemical contents.

RESULTS: Grossly, superficial degenerative change of the cartilage (i.e., roughened texture and erosion) corresponded with regions of high T1rho values. High T1rho values correlated with low indentation stiffness, and the strength of correlation varied slightly with the ROI size. Spatial variations in T1rho values correlated positively with that of the water content (R2 = 0.10, p < 0.05) and negatively with the variations in the GAG content (R2 = 0.13, p < 0.01). Multivariate correlation (R2 = 0.23, p < 0.01) was stronger than either of the univariate correlations.

CONCLUSION: These results demonstrate the sensitivity of T1rho values to spatially varying function and composition of cartilage and that the strength of correlation depends on the method of data analysis and consideration of multiple variables.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Bae WC, Statum S, Masuda K, et al. T1rho MR properties of human patellar cartilage: correlation with indentation stiffness and biochemical contents. Skeletal Radiol. 2023. PMID: 37740079. doi:10.1007/s00256-023-04458-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。