文献速递甲状腺与浅表头颈US

两种甲状腺结节超声风险分层系统诊断性能比较:系统评价与Meta分析

Comparison of diagnostic performance of two ultrasound risk stratification systems for thyroid nodules: a systematic review and meta-analysis.
PubMed 文献 · Radiol Med · 2023-09-04

该系统评价与Meta分析纳入18项研究共25,422例患者,比较韩国甲状腺影像报告和数据系统(Korean TI-RADS)与美国甲状腺协会甲状腺影像报告和数据系统(ATA TI-RADS)的诊断性能。Korean TI-RADS与ATA TI-RADS的最高AUC分别为0.893和0.887,高怀疑类别为最佳截断值;两者直接比较诊断准确性无显著差异。

要点

  • Korean TI-RADS高怀疑类别诊断恶性结节的敏感度71.3%、特异度7.9%、AUC 0.893。
  • ATA TI-RADS高怀疑类别诊断恶性结节的敏感度73.5%、特异度86.4%、AUC 0.887。
  • 两种TI-RADS直接比较诊断准确性无显著差异。

核心结论

  • 两种风险分层系统诊断性能良好,AUC高且无显著差异。
  • 理想截断值可能取决于医疗条件或甲状腺结节,因为截断点变化可能相互改变敏感度和特异度。

研究设计与样本

  • 系统评价与Meta分析,检索PubMed、SCOPUS、Embase、Web of Science和Cochrane Library数据库至2022年8月。
  • 纳入18项研究共25,422例患者,提取真阳性、假阳性、真阴性和假阴性值及特征。

诊断标准与关键数值

  • Korean TI-RADS最高AUC为0.893,高怀疑类别为最佳截断值,敏感度71.3%、特异度7.9%、诊断比值比20.0289。
  • ATA TI-RADS最高AUC为0.887,高怀疑类别为最佳截断值,敏感度73.5%、特异度86.4%、诊断比值比20.9076。
  • 两种TI-RADS直接比较诊断准确性无显著差异。

临床应用与阅片要点

  • 原文结论指出理想截断值可能取决于医疗条件或甲状腺结节,因为截断点变化可能相互改变敏感度和特异度。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To assume the ideal cut-off values and diagnostic performance of two thyroid imaging reporting and data systems published by the Korean Thyroid Association/Korean Society of Thyroid Radiology (Korean TI-RADS) and the American Thyroid Association (ATA TI-RADS).

METHODS: Eighteen studies with 25,422 patients from PubMed, SCOPUS, Embase, Web of Science, and Cochrane Library databases up to August 2022. True and false positive and negative values with characteristics were extracted.

RESULTS: The highest area under the receiver operating characteristic curve (AUC) was 0.893 and 0.887 for Korean and ATA TI-RADS. High suspicion was judged as the best cut-off value with the highest AUC based on optimal sensitivity and specificity. In determining the risk of malignant thyroid nodules, high suspicion in Korean and ATA TI-RADS showed sensitivity as 71.3% and 73.5%, specificity as 7.9% and 86.4%, diagnostic odds ratios as 20.0289 and 20.9076, AUC as 0.893 and 0.887. There was no significant difference when directly comparing the diagnostic accuracy of both TI-RADS.

CONCLUSION: The two risk stratification systems had good diagnostic performance with high AUC and no significant differences. The ideal cut-off can depend on the medical condition or thyroid nodules, because the changes of cut-off point may reciprocally alter sensitivity and specificity.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Kang YJ, Ahn HS, Stybayeva G, et al. Comparison of diagnostic performance of two ultrasound risk stratification systems for thyroid nodules: a systematic review and meta-analysis. Radiol Med. 2023. PMID: 37665419. doi:10.1007/s11547-023-01709-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。