乳腺X线摄影图像采集因素中的压迫压力与压迫板倾斜是否与筛查中乳腺癌检出相关
基于英国人群筛查项目80,495次乳腺X线检查,评估客观测量的压迫压力与压迫板倾斜和同期筛查、后续筛查及间期乳腺癌检出的关联。结果显示压迫压力与同期筛查乳腺癌检出呈负相关(压力分布最高三分位 vs 最低三分位 OR 0.74,95%CI 0.60–0.92,线性趋势 P=0.007),压迫板倾斜与任何时点乳腺癌检出均无关联。
要点
- 压迫压力较高与同期筛查乳腺癌检出几率降低相关(最高三分位 vs 最低三分位 OR 0.74,95%CI 0.60–0.92)。
- 压迫板倾斜与同期筛查、后续筛查或间期乳腺癌检出均无关联证据。
- 中等压迫压力与间期乳腺癌检出几率降低的关联证据较弱(中间三分位 vs 最低三分位 OR 0.63,95%CI 0.38–1.05,P=0.079)。
核心结论
- 研究结果与「压迫压力而非压迫板倾斜通过影响乳腺X线摄影检出癌症的能力来影响筛查性能」这一观点一致。
研究设计与样本
- 对英国人群筛查项目中80,495次乳腺X线检查进行自动压迫压力与压迫板倾斜估计,采用调整logistic回归估计与同期筛查乳腺癌(777例)的关联,并采用巢式病例对照设计通过条件logistic回归估计与间期乳腺癌(148例/625例年龄匹配对照)及后续筛查乳腺癌(344例/1436例对照)的关联。
诊断标准与关键数值
- 压迫压力与同期筛查乳腺癌检出几率呈负相关:压力分布最高三分位 vs 最低三分位 OR 0.74(95%CI 0.60–0.92),线性趋势 P=0.007。
- 中等压迫压力与间期乳腺癌检出几率降低的关联证据较弱:中间三分位 vs 最低三分位 OR 0.63(95%CI 0.38–1.05),P=0.079。
- 压迫压力与后续筛查乳腺癌检出几率无关联。
- 压迫板倾斜与同期筛查、后续筛查或间期乳腺癌检出几率均无关联证据。
临床应用与阅片要点
- 作者结论认为,筛查时压迫压力不足或过度可能降低检出癌症的能力,导致间期乳腺癌病例增多。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To assess the associations between objectively measured mammographic compression pressure and paddle tilt and breast cancer (BC) detected at the same ("contemporaneous") screen, subsequent screens, or in-between screens (interval cancers).
METHODS: Automated pressure and paddle tilt estimates were derived for 80,495 mammographic examinations in a UK population-based screening programme. Adjusted logistic regression models were fitted to estimate the associations of compression parameters with BC detected at contemporaneous screen (777 cases).Nested case-control designs were used to estimate associations of pressure and tilt with: (a) interval cancer (148 cases/625 age-matched controls) and (b) subsequent screen-detected cancer (344/1436), via conditional logistic regression.
RESULTS: Compression pressure was negatively associated with odds of BC at contemporaneous screen (odds ratio (OR) for top versus bottom third of the pressure distribution: 0.74; 95% CI 0.60, 0.92; P-for-linear-trend (Pt) = 0.007). There was weak evidence that moderate pressure at screening was associated with lower odds of interval cancer (OR for middle versus bottom third: 0.63; 95% CI 0.38, 1.05; p = 0.079), but no association was found between pressure and the odds of BC at subsequent screen. There was no evidence that paddle tilt was associated with the odds of contemporaneous, subsequent screen or interval cancer detection.
CONCLUSIONS: Findings are consistent with compression pressure, but not paddle tilt, affecting the performance of mammographic screening by interfering with its ability to detect cancers.
ADVANCES IN KNOWLEDGE: Inadequate or excessive compression pressure at screening may contribute to a reduced ability to detect cancers, resulting in a greater number of interval cancer cases.
引用
- Hudson SM, Wilkinson LS, De Stavola BL, et al. Are mammography image acquisition factors, compression pressure and paddle tilt, associated with breast cancer detection in screening? Br J Radiol. 2023. PMID: 37660396. doi:10.1259/bjr.20230085
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。