非肿块型乳腺病变的超声造影动力学定量特征:一项前瞻性研究
前瞻性纳入连续非肿块型乳腺病变患者,行灰阶超声、超声造影及病理诊断,30岁以上患者加做标准乳腺X线。三位放射科医师按BI-RADS分类,结合超声造影定量参数重新评估。联合平均对比信号强度、流入速率和40秒增强强度三个参数后,AUC达0.904,敏感度95.8%,特异度70.0%。
要点
- 恶性非肿块型乳腺病变超声造影表现为高增强、快进快出。
- 平均对比信号强度、流入速率和40秒增强强度是诊断恶性最有效的动力学参数。
- 联合超声造影定量参数可提高BI-RADS分类的诊断效能。
核心结论
- 恶性非肿块型乳腺病变的超声造影特征为高增强、快进快出,联合灰阶超声可提高诊断效能。
研究设计与样本
- 前瞻性研究,连续纳入非肿块型乳腺病变患者,最终纳入30个良性病变和24个恶性病变,其中导管原位癌占恶性病变的15/24;所有病变行灰阶超声和超声造影检查并以病理为参考标准,30岁以上患者行标准乳腺X线检查,由三位独立放射科医师评估并分类。
关键影像表现/征象
- 恶性非肿块型乳腺病变超声造影表现为高增强。
- 恶性非肿块型乳腺病变超声造影表现为快速流入和快速流出。
诊断标准与关键数值
- 平均对比信号强度(AI)截断值为205.2。
- 流入速率(WiR)截断值为127.8。
- 40秒增强强度(I40)截断值为136.4。
- 联合AI、WiR和I40三个截断值后,AUC为0.904,敏感度95.8%,特异度70.0%。
临床应用与阅片要点
- 对非肿块型乳腺病变行超声造影定量分析,关注平均对比信号强度、流入速率和40秒增强强度。
- 联合超声造影定量参数与灰阶超声BI-RADS分类可提高诊断恶性非肿块型乳腺病变的敏感度。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To characterize non-mass breast lesions (NML) quantitatively by contrast-enhanced ultrasound (CEUS) and to evaluate its additional diagnostic value based on the Breast Imaging Reporting and Data System (BI-RADS) categories.
METHODS: A prospective study was performed among consecutive patients with NMLs. All lesions were examined by grayscale ultrasound and CEUS and diagnosed on pathology. Standard mammograms were obtained in the patients over 30 years old. Three independent radiologists assessed the features on grayscale ultrasound and mammograms and classified NMLs according to BI-RADS categories. Combined with the quantitative analysis in CEUS, the BI-RADS categories were reassessed, and the sensitivity, specificity, positive-predictive value, negative-predictive value and area under the receiver operating characteristic curve (AUC) were calculated for the evaluation of the diagnostic performance.
RESULTS: 30 benign and 24 malignant NMLs were finally enrolled in this study, with ductal carcinoma in situ being the majority of malignant (15/24). Average contrast signal intensity (AI), wash-in rate (WiR) and enhancement intensity at 40 s (I40) were found to be the most efficient kinetic parameters to diagnose malignant NMLs. Combined with the cut-off values of 205.2 for AI, 127.8 for WiR and 136.4 for I40, the diagnostic accuracy was improved (AUC = 0.904), with the sensitivity of 95.8% and the specificity of 70.0%.
CONCLUSION: The results suggested that hyperenhancement and rapid wash-in and wash-out are the characteristics of malignant NMLs. The kinetic analysis using CEUS can reflect hypervascular nature of malignant NMLs, thus improving the diagnostic performance combined with grayscale ultrasound.
ADVANCES IN KNOWLEDGE: In this study, we quantified the enhancement characteristics of non-mass breast lesions with CEUS. We revealed that the combination of CEUS and conventional ultrasound provided higher sensitivity for diagnosing malignant NMLs.
引用
- Cai YY, Du YC, Zhao L, et al. The kinetic quantitative characteristics of non-mass breast lesions with contrast-enhanced ultrasound: a prospective study. Br J Radiol. 2023. PMID: 37660395. doi:10.1259/bjr.20221002
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。