文献速递乳腺US

剪切波弹性成像在乳腺癌诊断中的观察者内与观察者间信度

Intra- and Interobserver Reliability of Shear Wave Elastography in Breast Cancer Diagnosis.
PubMed 文献 · J Ultrasound Med · 2023-09-29

研究纳入7国12家机构1288例BI-RADS 3或4类乳腺病变女性,评估剪切波弹性成像的观察者内与观察者间信度。观察者内信度ICC>0.9为优秀,观察者间信度ICC为0.7为中等;BI-RADS 3与4类、良性与恶性病变间观察者内信度无临床显著差异。

要点

  • 剪切波弹性成像观察者内信度优秀(ICC>0.9),观察者间信度中等(ICC为0.7)。
  • BI-RADS 3类与4类病变的观察者内信度无临床显著差异。
  • 组织病理良性或恶性病变的观察者内信度无临床显著差异。

核心结论

  • 剪切波弹性成像在实性乳腺肿块评估中显示优秀的观察者内信度和中等的观察者间信度。

研究设计与样本

  • 前瞻性多中心研究,纳入7国12家机构1288例BI-RADS 3至4类乳腺病变女性,均行常规B型超声和剪切波弹性成像;1243例(96.5%)由委员会认证资深医师完成三次重复常规B型超声及剪切波弹性成像测量,375例(29.1%)由第二位医师额外行B型超声和剪切波弹性成像检查;计算组内相关系数评估信度。

诊断标准与关键数值

  • 观察者内信度ICC>0.9,为优秀相关。
  • 观察者间信度ICC为0.7,为中等相关。
  • BI-RADS 3类或4类病变以及组织病理良性或恶性病变的观察者内信度无临床显著差异。

临床应用与阅片要点

  • 剪切波弹性成像观察者内信度优秀、观察者间信度中等,阅片和报告时需注意不同医师测量间的差异。

局限性

  • 原文指出尚缺乏评估剪切波弹性成像信度的大样本、前瞻性、多中心数据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Shear wave elastography (SWE) is increasingly used in breast cancer diagnostics. However, large, prospective, multicenter data evaluating the reliability of SWE is missing. We evaluated the intra- and interobserver reliability of SWE in patients with breast lesions categorized as BIRADS 3 or 4.

METHODS: We used data of 1288 women at 12 institutions in 7 countries with breast lesions categorized as BIRADS 3 to 4 who underwent conventional B-mode ultrasound and SWE. 1243 (96.5%) women had three repetitive conventional B-mode ultrasounds as well as SWE measurements performed by a board-certified senior physician. 375 of 1288 (29.1%) women received an additional ultrasound examination with B-mode and SWE by a second physician. Intraclass correlation coefficients (ICC) were calculated to examine intra- and interobserver reliability.

RESULTS: ICC for intraobserver reliability showed an excellent correlation with ICC >0.9, while interobserver reliability was moderate with ICC of 0.7. There were no clinically significant differences in intraobserver reliability when SWE was performed in lesions categorized as BI-RADS 3 or 4 as well as in histopathologically benign or malignant lesions.

CONCLUSION: Reliability of additional SWE was evaluated on a study cohort consisting of 1288 breast lesions categorized as BI-RADS 3 and 4. SWE shows an excellent intraobserver reliability and a moderate interobserver reliability in the evaluation of solid breast masses.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Togawa R, Pfob A, Büsch C, et al. Intra- and Interobserver Reliability of Shear Wave Elastography in Breast Cancer Diagnosis. J Ultrasound Med. 2023. PMID: 37772458. doi:10.1002/jum.16344

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。