基于MR的影像组学列线图纳入瘤周区域信息预测I期子宫内膜样腺癌深肌层浸润:一项初步研究
回顾性分析202例I期子宫内膜样腺癌患者,训练队列为1.5 T MR(n=131),验证队列为3.0 T MR(n=71),基于ADC图和T2WI提取瘤内及瘤周影像组学特征,结合形态学和临床参数构建列线图预测深肌层浸润,训练队列AUC为0.927(95%CI:0.865, 0.967),验证队列AUC为0.921(95%CI:0.872, 0.948),作者认为该列线图术前预测深肌层浸润表现良好,可能有助于手术患者管理。
要点
- 基于ADC图和T2WI的瘤内及瘤周影像组学列线图可术前预测I期子宫内膜样腺癌深肌层浸润。
- 训练队列AUC 0.927(95%CI:0.865, 0.967),验证队列AUC 0.921(95%CI:0.872, 0.948)。
- 瘤内与瘤周影像组学特征互补,模型在不同MR场强下验证显示泛化性良好。
核心结论
- 基于MR的影像组学列线图在术前预测I期子宫内膜样腺癌肌层浸润深度方面表现良好,可能有助于手术患者管理。
研究设计与样本
- 回顾性分析202例患者,分为训练队列(1.5 T MR,n=131)和验证队列(3.0 T MR,n=71),采集轴位ADC图和T2WI,从瘤内和瘤周区域提取影像组学特征,采用LASSO回归、单因素分析和多因素logistic回归筛选特征并构建列线图。
诊断标准与关键数值
- 列线图纳入10个影像组学特征、4个形态学参数和1个临床特征;训练队列AUC 0.927(95%CI:0.865, 0.967),特异度92.0%、敏感度78.9%;验证队列AUC 0.921(95%CI:0.872, 0.948),特异度83.0%、敏感度77.8%。
临床应用与阅片要点
- 作者认为该列线图术前预测I期子宫内膜样腺癌深肌层浸润表现良好,可能有助于手术患者管理;瘤内与瘤周影像组学特征互补,模型在不同MR场强下验证显示泛化性良好。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To develop and validate an MR-based radiomics nomogram combining different imaging sequences (ADC mapping and T2 weighted imaging (T2WI)), different tumor regions (combined intra- and peritumoral regions), and different parameters (clinical features, tumor morphological features, and radiomics features) while considering different MR field strengths in predicting deep myometrial invasion (MI) in Stage I endometrioid adenocarcinoma (EEA).
METHODS: A total of 202 patients were retrospectively analyzed and divided into two cohorts (training cohort, 1.5 T MR, n = 131; validation cohort, 3.0 T MR, n = 71). Axial ADC mapping and T2WI were conducted. Radiomics features were extracted from intra- and peritumoral regions. Least absolute shrinkage and selection operator regression, univariate analysis, and multivariate logistic regression were used to select radiomics features and tumor morphological and clinical parameters. The area under the receiver operator characteristic curve (AUC) was calculated to evaluate the performance of the prediction model and radiomics nomogram.
RESULTS: Ten radiomics features, 4 morphological parameters and 1 clinical characteristic were selected. The radiomics nomogram achieved good discrimination between the superficial and deep MI cohorts. The AUC was 0.927 (95% confidence interval [CI]: 0.865, 0.967) in the training cohort and 0.921 (95% CI: 0.872, 0.948) in the validation cohort. The specificity and sensitivity were 92.0 and 78.9% in the training cohort and 83.0 and 77.8% in the validation cohort, respectively.
CONCLUSION: The radiomics nomogram showed good performance in predicting the depth of MI in Stage I EEA before surgery and might be useful for surgical patient management.
ADVANCES IN KNOWLEDGE: An MR-based radiomics nomogram was useful for predicting deep MI in Stage I EEA patients (AUCtrain = 0.927, AUCvalidation = 0.921). The intra- and peritumoral radiomics features complemented each other. The nomogram was developed and validated with different MR field strengths, suggesting that the model demonstrates good generalizability.
引用
- Yan B, Zhao T, Li Z, et al. An MR-based radiomics nomogram including information from the peritumoral region to predict deep myometrial invasion in stage I endometrioid adenocarcinoma: a preliminary study. Br J Radiol. 2023. PMID: 37751166. doi:10.1259/bjr.20230026