文献速递妇产影像腹部US

经阴道超声后路标准技术诊断子宫骶韧带及子宫颈后方深部子宫内膜异位症的前瞻性诊断试验准确性研究

Prospective diagnostic test accuracy of transvaginal ultrasound posterior approach for uterosacral ligament and torus uterinus deep endometriosis.
PubMed 文献 · Ultrasound Obstet Gynecol · 2024-01-01

在加拿大McMaster大学医学中心三级子宫内膜异位症门诊连续纳入54例同期行经阴道超声和手术的参与者,由专家超声医师采用标准化后路技术评估子宫骶韧带及子宫颈后方深部子宫内膜异位症,以腹腔镜直视为参考标准,左侧子宫骶韧带、右侧子宫骶韧带及子宫颈后方深部子宫内膜异位症患病率分别为42.6%、22.2%和14.8%,该技术诊断准确性高。

要点

  • 标准化经阴道超声后路技术诊断子宫颈后方深部子宫内膜异位症的准确度、敏感度、特异度、阳性预测值、阴性预测值均为100%。
  • 诊断左侧子宫骶韧带深部子宫内膜异位症的敏感度为82.6%、特异度为100%,诊断右侧子宫骶韧带深部子宫内膜异位症的敏感度为75.0%、特异度为100%。
  • 作者认为在将该技术视为标准方法前,应进一步开展研究,尤其是由经验较少的观察者进行评估。

核心结论

  • 采用标准化经阴道超声后路技术评估子宫骶韧带及子宫颈后方深部子宫内膜异位症具有高诊断试验准确性,但作者认为在将其视为标准方法前应进一步研究,尤其是由经验较少的观察者评估。

研究设计与样本

  • 前瞻性诊断试验准确性研究,在加拿大安大略省汉密尔顿市McMaster大学医学中心三级子宫内膜异位症门诊开展,2020年8月10日至2021年10月31日连续纳入54例成功完成经阴道超声及本团队手术的参与者。

诊断标准与关键数值

  • 以腹腔镜直视手术所见为参考标准,左侧子宫骶韧带深部子宫内膜异位症的患病率为42.6%,经阴道超声后路技术诊断准确度为92.6%(95%CI 82.1-97.9%)、敏感度为82.6%(95%CI 61.2-95.1%)、特异度为100%(95%CI 88.8-100%)、阳性预测值为100%、阴性预测值为88.6%(95%CI 76.1-95.0%)。
  • 右侧子宫骶韧带深部子宫内膜异位症的患病率为22.2%,经阴道超声后路技术诊断准确度为94.4%(95%CI 84.6-98.8%)、敏感度为75.0%(95%CI 42.8-94.5%)、特异度为100%(95%CI 91.6-100%)、阳性预测值为100%、阴性预测值为93.3%(95%CI 84.0-97.4%)。
  • 子宫颈后方深部子宫内膜异位症的患病率为14.8%,经阴道超声后路技术诊断准确度为100%(95%CI 93.4-100%)、敏感度为100%(95%CI 63.1-100%)、特异度为100%(95%CI 92.3-100%)、阳性预测值为100%、阴性预测值为100%。

临床应用与阅片要点

  • 经阴道超声采用标准化后路技术,由专家超声医师进行操作和判读,以腹腔镜直视手术所见为参考标准。
  • 作者认为在将该技术视为标准方法前,应进一步开展研究,尤其是由经验较少的观察者进行评估。

局限性

  • 作者指出在将该技术视为标准方法前,应进一步开展研究,尤其是由经验较少的观察者进行评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To determine the diagnostic test accuracy of transvaginal ultrasound (TVS) using a standardized technique for the diagnosis of deep endometriosis (DE) of the uterosacral ligaments (USLs) and adjacent torus uterinus (TU).

METHODS: This was a prospective diagnostic test accuracy study conducted at the McMaster University Medical Center Tertiary Endometriosis Clinic, Hamilton, ON, Canada. Consecutive participants were enrolled if they successfully underwent TVS and surgery by our team from 10 August 2020 to 31 October 2021. The index test was TVS using a standardized posterior approach performed and interpreted by an expert sonologist. The reference standard included direct surgical visualization on laparoscopy by the same person who performed and interpreted the ultrasound scans. Accuracy, sensitivity, specificity, positive and negative predictive values (PPV and NPV) and positive and negative likelihood ratios were calculated for the TVS posterior approach for each location using the reference standard.

RESULTS: There were 54 consecutive participants included upon completion of laparoscopy and histological assessment. The prevalence of DE for the left USL, right USL and TU was 42.6%, 22.2% and 14.8%, respectively. Based on surgical visualization as the reference standard, TVS demonstrated an accuracy of 92.6% (95% CI, 82.1-97.9%), sensitivity of 82.6% (95% CI, 61.2-95.1%), specificity of 100% (95% CI, 88.8-100%), PPV of 100% and NPV of 88.6% (95% CI, 76.1-95.0%) for diagnosing DE in the left USL. For DE of the right USL, TVS demonstrated an accuracy of 94.4% (95% CI, 84.6-98.8%), sensitivity of 75.0% (95% CI, 42.8-94.5%), specificity of 100% (95% CI, 91.6-100%), PPV of 100% and NPV of 93.3% (95% CI, 84.0-97.4%). For DE of the TU, TVS demonstrated an accuracy of 100% (95% CI, 93.4-100%), sensitivity of 100% (95% CI, 63.1-100%), specificity of 100% (95% CI, 92.3-100%), PPV of 100% and NPV of 100%.

CONCLUSIONS: We observed high diagnostic test accuracy of the evaluated standardized TVS technique for assessing DE of the USLs and TU. Further studies evaluating this technique should be performed, particularly with less experienced observers, before considering this technique as the standard approach. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Freger SM, Turnbull V, McGowan K, et al. Prospective diagnostic test accuracy of transvaginal ultrasound posterior approach for uterosacral ligament and torus uterinus deep endometriosis. Ultrasound Obstet Gynecol. 2024. PMID: 37725753. doi:10.1002/uog.27492

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。