弥散峰度成像多定量参数预测子宫内膜癌微卫星不稳定状态的价值
回顾性分析38例子宫内膜癌患者(12例MSI、26例MSS)的术前1.5T MR弥散峰度成像数据,比较两组肿瘤实质的MK、Ka、Kr、FA、FAk、MD、Da、Dr值。MSI组MK和Ka值高于MSS组(P<0.05),MD和Dr值低于MSS组(P<0.05);MK、Ka、MD、Dr预测MSI的AUC分别为0.763、0.729、0.731、0.748。
要点
- MSI组MK、Ka值高于MSS组,MD、Dr值低于MSS组。
- MK预测MSI的AUC为0.763,敏感度58.3%、特异度96.2%。
- DKI多参数可辅助预测子宫内膜癌MSI状态。
核心结论
- DKI可提供多个定量参数用于预测子宫内膜癌MSI状态,并辅助妇科医生优化患者治疗方案。
研究设计与样本
- 回顾性分析38例子宫内膜癌患者,其中12例MSI、26例MSS,均行术前1.5T MR检查,由两名观察者分别测量肿瘤实质DKI序列的MK、Ka、Kr、FA、FAk、MD、Da、Dr值。
关键影像表现/征象
- MSI组肿瘤实质MK、Ka值高于MSS组(P<0.05),MD、Dr值低于MSS组(P<0.05)。
诊断标准与关键数值
- MK预测MSI的AUC为0.763,敏感度58.3%,特异度96.2%。
- Ka预测MSI的AUC为0.729,敏感度50.0%,特异度92.3%。
- MD预测MSI的AUC为0.731,敏感度65.4%,特异度75.0%。
- Dr预测MSI的AUC为0.748,敏感度61.5%,特异度83.3%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To explore the value of Diffusion kurtosis imaging (DKI) with multiple quantitative parameters in predicting microsatellite instability (MSI) status in endometrial carcinoma (EC).
METHODS: Data of 38 patients with EC were retrospectively analyzed, including 12 MSI and 26 microsatellite stability (MSS). All patients underwent preoperative 1.5T MR examination. The quantitative values of the DKI sequence in the tumor parenchyma of the two groups, including mean kurtosis (MK), axial kurtosis (Ka), radial kurtosis (Kr), fractional anisotropy (FA), fractional anisotropy of kurtosis (FAk), mean diffusivity (MD), axial diffusivity (Da), and radial diffusivity (Dr) were measured by two observers, respectively.
RESULTS: The MK, Ka, Kr, FA, FAk, MD, Da, and Dr values of the MSI group were 1.074 ± 0.162, 1.253 ± 0.229, 0.886 ± 0.205, 0.207 ± 0.041, 0.397 ± 0.129, 0.890 ± 0.158 μm2/ms, 1.083 ± 0.218 μm2/ms, and 0.793 ± 0.133 μm2/ms, and 0.956 (0.889,1.002), 1.048 ± 0.211, 0.831 ± 0.099, 0.188 ± 0.061, 0.334 (0.241,0.410), 1.043 ± 0.217 μm2/ms, 1.235 ± 0.229 μm2/ms, and 0.946 ± 0.215 μm2/ms in the MSS group. The MK and Ka values of the MSI group were higher than those of the MSS group (P<0.05), while the MD and Dr values were lower than those of the MSS group (P<0.05). The AUC of MK, Ka, MD, and Dr values in predicting MSI status of EC was 0.763, 0.729, 0.731, 0.748, respectively. The sensitivity was 58.3%, 50.0%, 65.4%, 61.5%, and the specificity was 96.2%, 92.3%, 75.0%, 83.3%, respectively.
CONCLUSION: DKI can provide multiple quantitative parameters for predicting the MSI status of EC, and assist gynecologist to optimize the treatment plan for the patients.
引用
- Song Q, Dong W, Tian S, et al. Diffusion kurtosis imaging with multiple quantitative parameters for predicting microsatellite instability status of endometrial carcinoma. Abdom Radiol (NY). 2023. PMID: 37740047. doi:10.1007/s00261-023-04041-6