正常妊娠与胎儿生长受限妊娠胎盘对高氧反应的T2*及BOLD效应:多中心队列研究
这项前瞻性多中心研究在法国巴黎两个中心纳入19例胎儿生长受限(FGR)妊娠和75例非FGR妊娠,用1.5T磁共振多回波梯度回波序列测量常氧与高氧条件下胎盘T2*值并计算相对BOLD效应。结果显示人胎盘存在对高氧的相对BOLD效应(中位数33.8%),FGR与非FGR妊娠间该效应无显著差异(34.4% vs 33.7%,P=0.95),但FGR妊娠基线T2* Z评分显著低于非FGR妊娠(中位数-1.27 vs 0.33,P=0.001)。
要点
- 人胎盘高氧条件下相对BOLD效应中位数为33.8%(IQR 22.5-48.0%)。
- FGR与非FGR妊娠的相对BOLD效应无显著差异(34.4% vs 33.7%,P=0.95)。
- FGR妊娠基线T2* Z评分显著低于非FGR妊娠(中位数-1.27 vs 0.33,P=0.001)。
核心结论
- 研究证实人胎盘存在BOLD效应,且FGR妊娠基线T2*值显著降低;作者指出需进一步研究评估这些参数能否在胎盘功能不全对胎儿生长产生临床影响之前将其检出。
研究设计与样本
- 前瞻性多中心研究(NCT02238301),纳入19例FGR妊娠(超声估测胎儿体重<第5百分位)和75例非FGR妊娠,在法国巴黎两个中心招募,使用1.5T磁共振系统,两中心采用相同的多回波梯度回波序列。
关键影像表现/征象
- 高氧条件下人胎盘出现相对BOLD效应,中位数为33.8%(IQR 22.5-48.0%)。
- FGR妊娠基线T2* Z评分(按MRI时孕周校正)中位数为-1.27(IQR -4.87至-0.10),非FGR妊娠为0.33(IQR -0.81至1.02)。
- 随后分娩SGA新生儿的妊娠(n=23)基线T2* Z评分中位数为-0.75(IQR -3.48至0.29),分娩非SGA新生儿的妊娠(n=62)为0.35(IQR -0.79至1.05)。
诊断标准与关键数值
- FGR定义:超声估测胎儿体重(EFW)<第5百分位。
- 相对BOLD效应计算公式:100×(高氧T2*-基线T2*)/基线T2*。
- FGR与非FGR妊娠相对BOLD效应比较:中位数34.4%(IQR 24.1-48.5%)vs 33.7%(IQR 22.7-47.4%),P=0.95。
- FGR与非FGR妊娠基线T2* Z评分比较:中位数-1.27(IQR -4.87至-0.10)vs 0.33(IQR -0.81至1.02),P=0.001。
- SGA与非SGA妊娠基线T2* Z评分比较:中位数-0.75(IQR -3.48至0.29)vs 0.35(IQR -0.79至1.05),P=0.01。
临床应用与阅片要点
- 作者指出需进一步研究评估基线T2*等参数能否在胎盘功能不全对胎儿生长产生临床影响之前将其检出。
局限性
- 作者指出需进一步研究评估这些参数能否在胎盘功能不全对胎儿生长产生临床影响之前将其检出。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Blood-oxygen-level-dependent (BOLD) magnetic resonance imaging (MRI) facilitates the non-invasive in-vivo evaluation of placental oxygenation. The aims of this study were to identify and quantify a relative BOLD effect in response to hyperoxia in the human placenta and to compare it between pregnancies with and those without fetal growth restriction (FGR).
METHODS: This was a prospective multicenter study (NCT02238301) of 19 pregnancies with FGR (estimated fetal weight (EFW) on ultrasound < 5th centile) and 75 non-FGR pregnancies (controls) recruited at two centers in Paris, France. Using a 1.5-Tesla MRI system, the same multi-echo gradient-recalled echo (GRE) sequences were performed at both centers to obtain placental T2* values at baseline and in hyperoxic conditions. The relative BOLD effect was calculated according to the equation 100 × (hyperoxic T2* - baseline T2*)/baseline T2*. Baseline T2* values and relative BOLD effect were compared according to EFW (FGR vs non-FGR), presence/absence of Doppler anomalies and birth weight (small-for-gestational age (SGA) vs non-SGA).
RESULTS: We observed a relative BOLD effect in response to hyperoxia in the human placenta (median, 33.8% (interquartile range (IQR), 22.5-48.0%)). The relative BOLD effect did not differ significantly between pregnancies with and those without FGR (median, 34.4% (IQR, 24.1-48.5%) vs 33.7% (22.7-47.4%); P = 0.95). Baseline T2* Z-score adjusted for gestational age at MRI was significantly lower in FGR pregnancies compared with non-FGR pregnancies (median, -1.27 (IQR, -4.87 to -0.10) vs 0.33 (IQR, -0.81 to 1.02); P = 0.001). Baseline T2* Z-score was also significantly lower in those pregnancies that subsequently delivered a SGA neonate (n = 23) compared with those that delivered a non-SGA neonate (n = 62) (median, -0.75 (IQR, -3.48 to 0.29) vs 0.35 (IQR, -0.79 to 1.05); P = 0.01).
CONCLUSIONS: Our study confirms a BOLD effect in the human placenta and that baseline T2* values are significantly lower in pregnancies with FGR. Further studies are needed to evaluate whether such parameters may detect placental insufficiency before it has a clinical impact on fetal growth. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Jacquier M, Chalouhi G, Marquant F, et al. Placental T2* and BOLD effect in response to hyperoxia in normal and growth-restricted pregnancies: multicenter cohort study. Ultrasound Obstet Gynecol. 2024. PMID: 37743665. doi:10.1002/uog.27496
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。