基于深度学习的全胎儿MRI分割与胎儿体重估计:性能、重复性与再现性评估
本研究回顾性纳入348例胎龄19-39周的胎儿MRI数据,开发全胎儿分割深度学习模型并评估其重复性、再现性与准确性,构建基于MRI的正常胎儿体重生长曲线,并评估对生长受限胎儿的检出敏感度。方法在分割与体重估计上表现良好,对小于第3百分位胎儿的检出敏感度高。
要点
- 基于MRI的全胎儿分割模型Dice=0.973,体积差异比(VDR)=1.8%,与金标准一致性高。
- 估计胎儿体重与出生体重平均差异-0.39%(95%CI:-8.23%,7.45%),准确性高。
- 基于MRI的估计胎儿体重正确预测了全部18例≤第10百分位胎儿及17例生长受限胎儿中14例低于第3百分位的出生体重百分位。
核心结论
- 所提出的基于MRI的自动估计胎儿体重方法性能高,对识别生长受限胎儿敏感度高。
研究设计与样本
- 回顾性数据纳入348例胎龄19-39周胎儿:249例适于胎龄(AGA)、19例生长受限(FGR)、80例其他(含各种影像学异常)。开发带质量估计模块的全胎儿分割模型并在169例中评估。重复性评估为同一扫描仪重复扫描(n=22),再现性评估为不同扫描仪(n=6),准确性评估为与出生体重比较(n=7)。基于246例构建正常MRI生长曲线。
诊断标准与关键数值
- 分割模型Dice=0.973,绝对体积差异比(VDR)=1.8%,VDR平均差异=0.75%(95%CI:-3.95%,5.46)。重复性系数=4.01%,ICC=0.99;再现性平均差异=2.21%(95%CI:-1.92%,6.35%);估计胎儿体重与出生体重平均差异=-0.39%(95%CI:-8.23%,7.45%)。基于MRI的估计胎儿体重正确预测全部18例≤第10百分位胎儿及17例FGR中14例低于第3百分位的出生体重百分位;6例转诊MRI时为AGA的胎儿被发现低于第3百分位。
临床应用与阅片要点
- 本研究结果支持使用基于MRI的自动胎儿体重估计方法评估胎儿发育并检出有生长受限风险的胎儿。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To develop a deep-learning method for whole-body fetal segmentation based on MRI; to assess the method's repeatability, reproducibility, and accuracy; to create an MRI-based normal fetal weight growth chart; and to assess the sensitivity to detect fetuses with growth restriction (FGR).
METHODS: Retrospective data of 348 fetuses with gestational age (GA) of 19-39 weeks were included: 249 normal appropriate for GA (AGA), 19 FGR, and 80 Other (having various imaging abnormalities). A fetal whole-body segmentation model with a quality estimation module was developed and evaluated in 169 cases. The method was evaluated for its repeatability (repeated scans within the same scanner, n = 22), reproducibility (different scanners, n = 6), and accuracy (compared with birth weight, n = 7). A normal MRI-based growth chart was derived.
RESULTS: The method achieved a Dice = 0.973, absolute volume difference ratio (VDR) = 1.8% and VDR mean difference = 0.75% ([Formula: see text]: - 3.95%, 5.46), and high agreement with the gold standard. The method achieved a repeatability coefficient = 4.01%, ICC = 0.99, high reproducibility with a mean difference = 2.21% ([Formula: see text]: - 1.92%, 6.35%), and high accuracy with a mean difference between estimated fetal weight (EFW) and birth weight of - 0.39% ([Formula: see text]: - 8.23%, 7.45%). A normal growth chart (n = 246) was consistent with four ultrasound charts. EFW based on MRI correctly predicted birth-weight percentiles for all 18 fetuses ≤ 10thpercentile and for 14 out of 17 FGR fetuses below the 3rd percentile. Six fetuses referred to MRI as AGA were found to be < 3rd percentile.
CONCLUSIONS: The proposed method for automatic MRI-based EFW demonstrated high performance and sensitivity to identify FGR fetuses.
CLINICAL RELEVANCE STATEMENT: Results from this study support the use of the automatic fetal weight estimation method based on MRI for the assessment of fetal development and to detect fetuses at risk for growth restriction.
KEY POINTS: • An AI-based segmentation method with a quality assessment module for fetal weight estimation based on MRI was developed, achieving high repeatability, reproducibility, and accuracy. • An MRI-based fetal weight growth chart constructed from a large cohort of normal and appropriate gestational-age fetuses is proposed. • The method showed a high sensitivity for the diagnosis of small fetuses suspected of growth restriction.
引用
- Specktor-Fadida B, Link-Sourani D, Rabinowich A, et al. Deep learning-based segmentation of whole-body fetal MRI and fetal weight estimation: assessing performance, repeatability, and reproducibility. Eur Radiol. 2023. PMID: 37658890. doi:10.1007/s00330-023-10038-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。