文献速递泌尿生殖儿科影像MR

4D自由呼吸可变密度星堆功能磁共振尿路成像在无需镇静幼儿中的可行性与实施

Feasibility and Implementation of a 4D Free-Breathing Variable Density Stack-of-Stars Functional Magnetic Resonance Urography in Young Children Without Sedation.
PubMed 文献 · Invest Radiol · 2023-09-14

回顾性比较40例患儿4D自由呼吸可变密度星堆与标准屏气笛卡尔功能磁共振尿路成像,各20例按年龄、患肾、诊断配对。4D组总体图像质量、诊断信心、呼吸运动伪影及主动脉、肾、输尿管锐利度和对比度均显著更优(P<0.0001至0.005),双肾垂直运动显著减少(均P<0.001),vpDRF两阅片者差异方差显著更小(P=0.0003)。

要点

  • 4D自由呼吸星堆序列用于幼儿功能MRU可行,图像质量与诊断信心均优于标准屏气序列。
  • 4D序列显著减少双肾垂直呼吸运动(均P<0.001),呼吸运动伪影评分更佳。
  • vpDRF两阅片者间差异方差在4D组显著更小(P=0.0003),体积、vDRF、pDRF差异无统计学意义。

核心结论

  • 4D自由呼吸可变密度星堆成像用于幼儿功能MRU可行,图像质量改善、运动伪影减少、功能可分析性提高。

研究设计与样本

  • 回顾性研究,纳入2021年9月至2022年12月无全身麻醉下功能4D MRU患儿20例,与2016至2022年标准笛卡尔MRU按年龄、患肾、诊断1:1配对20例;共40例,每组10例采用喂食睡眠技术(中位年龄4D组3.3个月、标准组4.2个月),10例清醒(中位年龄4D组8.9岁、标准组8.6岁);由2名放射科医师独立采用4分Likert量表评分并以Bland-Altman和F检验比较。

关键影像表现/征象

  • 4D自由呼吸序列在总体图像质量、诊断信心、呼吸运动伪影以及主动脉、肾脏和输尿管锐利度与对比度方面均获两位阅片者显著更优评分(P<0.0001至0.005)。
  • 4D自由呼吸序列右肾和左肾垂直运动均显著减少(均P<0.001)。

诊断标准与关键数值

  • 图像质量采用4分Likert量表评分,4分为最佳,评价总体图像质量、诊断信心、呼吸运动伪影及主动脉、肾脏、输尿管锐利度和对比度。
  • 计算每肾体积、分肾体积(vDRF)、分肾Patlak功能(pDRF)及结合体积与Patlak功能的分肾功能(vpDRF)。
  • vpDRF两阅片者间差异方差在4D MRU显著更小(P=0.0003);体积(P=0.05)、vDRF(P=0.93)、pDRF(P=0.14)差异无统计学意义。

临床应用与阅片要点

  • 幼儿功能MRU可采用4D自由呼吸可变密度星堆序列,以减少呼吸运动伪影并提高图像可分析性。
  • 功能参数中vpDRF在4D序列下两阅片者间一致性更佳,体积、vDRF、pDRF未见显著差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Functional magnetic resonance urography (MRU) is well established in the diagnostic workup of urinary tract anomalies in children, providing comprehensive morphological and functional information. However, dynamic contrast-enhanced images acquired in the standard Cartesian k-space manner are prone to motion artifacts. A newly introduced 4D high spatiotemporal resolution dynamic contrast-enhanced magnetic resonance imaging based on variable density elliptical centric radial stack-of-stars sharing technique has shown improved image quality regarding motions under free breathing.

OBJECTIVE: The aims of this study were to implement this 4D free-breathing sequence for functional MRU and to compare its image quality and analyzability with standard breath-hold Cartesian MRU.

MATERIALS AND METHODS: We retrospectively evaluated all functional 4D MRU performed without general anesthesia between September 2021 and December 2022 and compared them with matched pairs (age, affected kidney, diagnosis) of standard Cartesian MRU between 2016 and 2022. Image analysis was performed by 2 radiologists independently regarding the following criteria using a 4-point Likert scale, with 4 being the best: overall image quality, diagnostic confidence, respiratory motion artifacts, as well as sharpness and contrast of aorta, kidneys, and ureters. We also measured vertical kidney motion due to respiratory motion and compared the variance for each kidney using F test. Finally, both radiologists calculated the volume, split renal volume (vDRF), split renal Patlak function (pDRF), and split renal function considering the volume and Patlak function (vpDRF) for each kidney. Values were compared using Bland-Altman plots and F test.

RESULTS: Forty children (20 for 4D free-breathing and standard breath-hold, respectively) were enrolled. Ten children of each group were examined using feed-and-sleep technique (median age: 4D, 3.3 months; standard, 4.2 months), 10 were awake (median age: 4D, 8.9 years; standard, 8.6 years). Overall image quality, diagnostic confidence, respiratory motion artifacts, as well as sharpness and contrast of the aorta, kidneys, and ureters were rated significantly better for 4D free-breathing compared with standard breath-hold by both readers ( P ranging from <0.0001 to 0.005). Vertical kidney motion was significantly reduced in 4D free-breathing for the right and the left kidney (both P < 0.001). There was a significantly smaller variance concerning the differences between the 2 readers for vpDRF in 4D MRU ( P = 0.0003). In contrast, no significant difference could be demonstrated for volume ( P = 0.05), vDRF ( P = 0.93), and pDRF ( P = 0.14).

CONCLUSIONS: We demonstrated the feasibility of applying a 4D free-breathing variable density stack-of-stars imaging for functional MRU in young pediatric patients with improved image quality, fewer motion artifacts, and improved functional analyzability.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Spogis J, Katemann C, Zhang S, et al. Feasibility and Implementation of a 4D Free-Breathing Variable Density Stack-of-Stars Functional Magnetic Resonance Urography in Young Children Without Sedation. Invest Radiol. 2023. PMID: 37707861. doi:10.1097/RLI.0000000000001014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。