文献速递泌尿生殖腹部MR

人工智能作为前列腺影像报告和数据系统3类病例诊断辅助工具:回顾性多中心队列研究结果

Artificial intelligence as diagnostic aiding tool in cases of Prostate Imaging Reporting and Data System category 3: the results of retrospective multi-center cohort study.
PubMed 文献 · Abdom Radiol (NY) · 2023-09-22

这项多中心回顾性队列研究邀请16名放射科医生在有和无人工智能辅助下解读87例初诊为PI-RADS 3类的前列腺多参数MRI病例,其中28例为临床显著前列腺癌、59例为非临床显著前列腺癌。人工智能辅助提高了诊断特异度和准确率,敏感度无显著差异,并缩短了阅读时间、提高了诊断信心。

要点

  • AI辅助使PI-RADS 3类病例诊断特异度从0.000升至0.695、准确率从0.322升至0.736(均P<0.001)。
  • AI辅助敏感度0.821与无AI的1.000相比无显著差异(P=1.000)。
  • AI辅助下诊断信心评分显著高于无AI(Cohen Kappa:-0.016)。

核心结论

  • 在AI辅助下,放射科医生对PI-RADS 3类病例的诊断准确率提高,诊断效率和诊断信心也增加。

研究设计与样本

  • 回顾性多中心队列研究,16名放射科医生参与,共纳入87例初诊为PI-RADS 3类的前列腺多参数MRI病例,其中28例为临床显著前列腺癌、59例为非临床显著前列腺癌;比较有和无AI辅助下的诊断效能、阅读时间和信心水平。

诊断标准与关键数值

  • AI在87例中改变了65例的诊断。
  • 59例非临床显著前列腺癌中,41例被正确降级为PI-RADS 1-2类,9例被错误升级为PI-RADS 4-5类。
  • 28例临床显著前列腺癌中,20例被正确升级为PI-RADS 4-5类,5例被错误降级为PI-RADS 1-2类。
  • AI辅助诊断特异度为0.695、准确率为0.736,无AI辅助分别为0.000和0.322,均P<0.001。
  • AI辅助敏感度0.821与无AI辅助1.000相比无显著差异(P=1.000)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To study the effect of artificial intelligence (AI) on the diagnostic performance of radiologists in interpreting prostate mpMRI images of the PI-RADS 3 category.

METHODS: In this multicenter study, 16 radiologists were invited to interpret prostate mpMRI cases with and without AI. The study included a total of 87 cases initially diagnosed as PI-RADS 3 by radiologists without AI, with 28 cases being clinically significant cancers (csPCa) and 59 cases being non-csPCa. The study compared the diagnostic efficacy between readings without and with AI, the reading time, and confidence levels.

RESULTS: AI changed the diagnosis in 65 out of 87 cases. Among the 59 non-csPCa cases, 41 were correctly downgraded to PI-RADS 1-2, and 9 were incorrectly upgraded to PI-RADS 4-5. For the 28 csPCa cases, 20 were correctly upgraded to PI-RADS 4-5, and 5 were incorrectly downgraded to PI-RADS 1-2. Radiologists assisted by AI achieved higher diagnostic specificity and accuracy than those without AI [0.695 vs 0.000 and 0.736 vs 0.322, both P < 0.001]. Sensitivity with AI was not significantly different from that without AI [0.821 vs 1.000, P = 1.000]. AI reduced reading time significantly compared to without AI (mean: 351 seconds, P < 0.001). The diagnostic confidence score with AI was significantly higher than that without AI (Cohen Kappa: -0.016).

CONCLUSION: With the help of AI, there was an improvement in the diagnostic accuracy of PI-RADS category 3 cases by radiologists. There is also an increase in diagnostic efficiency and diagnostic confidence.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Wang K, Xing Z, Kong Z, et al. Artificial intelligence as diagnostic aiding tool in cases of Prostate Imaging Reporting and Data System category 3: the results of retrospective multi-center cohort study. Abdom Radiol (NY). 2023. PMID: 37740046. doi:10.1007/s00261-023-03989-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。