深度学习超分辨率重建用于快速且运动稳健的前列腺T2加权MRI
这项前瞻性研究纳入109例疑似前列腺癌男性,比较低分辨率笛卡尔T2加权TSE序列经深度学习重建(T2DL)与标准笛卡尔T2C及非笛卡尔T2NC序列。T2DL采集时间较T2C和T2NC分别降低36%和29%,图像锐利度定性和定量均优于标准序列,且与T2NC的PI-RADS评分一致性极好(κ范围0.92-0.94)。
要点
- T2DL采集时间164秒±20,较T2C的257秒±32降低36%,较T2NC的230秒±28降低29%。
- T2DL锐利度中位评分5分(IQR 4-5),优于T2C和T2NC的4分(IQR 3-4)。
- T2DL与T2NC的PI-RADS评分一致性极好,κ范围0.92-0.94。
核心结论
- 低分辨率T2加权TSE序列经深度学习重建可实现加速采集并改善图像质量,同时PI-RADS评分与传统序列一致性极好。
研究设计与样本
- 前瞻性研究,纳入109例疑似前列腺癌男性(平均年龄68岁±8),于2022年8月至11月行前列腺MRI,采集T2C、T2NC及低分辨率笛卡尔T2DL序列,T2DL采用压缩感知深度学习去噪和分辨率放大重建。
关键影像表现/征象
- T2DL图像锐利度定性中位评分5分(IQR 4-5),T2C和T2NC均为4分(IQR 3-4),T2DL与两者比较P均<.001。
- T2DL边缘上升距离均值0.75 mm±0.39,T2C为1.15 mm±0.68(P<.001),T2NC为0.98 mm±0.65(P=.01)。
- T2DL采集时间均值164秒±20,T2C为257秒±32,T2NC为230秒±28,T2DL较T2C降低36%、较T2NC降低29%,P均<.001。
诊断标准与关键数值
- 图像锐利度定性采用五点Likert量表(1=不可诊断,5=极好),由两名阅片者评估。
- T2NC与T2DL的PI-RADS评分一致性κ范围0.92-0.94(95%CI:0.87,0.98)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Deep learning (DL) reconstructions can enhance image quality while decreasing MRI acquisition time. However, DL reconstruction methods combined with compressed sensing for prostate MRI have not been well studied. Purpose To use an industry-developed DL algorithm to reconstruct low-resolution T2-weighted turbo spin-echo (TSE) prostate MRI scans and compare these with standard sequences. Materials and Methods In this prospective study, participants with suspected prostate cancer underwent prostate MRI with a Cartesian standard-resolution T2-weighted TSE sequence (T2C) and non-Cartesian standard-resolution T2-weighted TSE sequence (T2NC) between August and November 2022. Additionally, a low-resolution Cartesian DL-reconstructed T2-weighted TSE sequence (T2DL) with compressed sensing DL denoising and resolution upscaling reconstruction was acquired. Image sharpness was assessed qualitatively by two readers using a five-point Likert scale (from 1 = nondiagnostic to 5 = excellent) and quantitatively by calculating edge rise distance. The Friedman test and one-way analysis of variance with post hoc Bonferroni and Tukey tests, respectively, were used for group comparisons. Prostate Imaging Reporting and Data System (PI-RADS) score agreement between sequences was compared by using Cohen κ. Results This study included 109 male participants (mean age, 68 years ± 8 [SD]). Acquisition time of T2DL was 36% and 29% lower compared with that of T2C and T2NC (mean duration, 164 seconds ± 20 vs 257 seconds ± 32 and 230 seconds ± 28; P < .001 for both). T2DL showed improved image sharpness compared with standard sequences using both qualitative (median score, 5 [IQR, 4-5] vs 4 [IQR, 3-4] for T2C and 4 [IQR, 3-4] for T2NC; P < .001 for both) and quantitative (mean edge rise distance, 0.75 mm ± 0.39 vs 1.15 mm ± 0.68 for T2C and 0.98 mm ± 0.65 for T2NC; P < .001 and P = .01) methods. PI-RADS score agreement between T2NC and T2DL was excellent (κ range, 0.92-0.94 [95% CI: 0.87, 0.98]). Conclusion DL reconstruction of low-resolution T2-weighted TSE sequences enabled accelerated acquisition times and improved image quality compared with standard acquisitions while showing excellent agreement with conventional sequences for PI-RADS ratings. Clinical trial registration no. NCT05820113 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Turkbey in this issue.
引用
- Bischoff LM, Peeters JM, Weinhold L, et al. Deep Learning Super-Resolution Reconstruction for Fast and Motion-Robust T2-weighted Prostate MRI. Radiology. 2023. PMID: 37750774. doi:10.1148/radiol.230427
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。