超声造影在囊性肾肿块评估中的作用

Role of Contrast-Enhanced Ultrasound in Evaluation of Cystic Renal Mass.
PubMed 文献 · J Ultrasound Med · 2023-09-07

研究前瞻性纳入40例经CECT诊断的囊性肾肿块患者,行CEUS并作Bosniak分级,以病理和临床随访为参考标准。CEUS敏感度和阴性预测值均为100%,特异度73.9%;CECT敏感度88.2%、特异度87%。CEUS与CECT诊断准确率相近,可作为筛查手段排除复杂性囊性肾肿块。

要点

  • CEUS对囊性肾肿块敏感度和阴性预测值均为100%,阴性时可不暴露于肾毒性对比剂和电离辐射。
  • CEUS特异度73.9%、阳性预测值73.9%,CECT特异度87%、阳性预测值90.9%。
  • CEUS与CECT诊断一致性K=0.66,与最终诊断一致性分别为K=0.71和K=0.75。

核心结论

  • CEUS与CECT诊断准确率相当,可作为筛查手段排除复杂性囊性肾肿块,且无需暴露于肾毒性对比剂和电离辐射。

研究设计与样本

  • 前瞻性研究,40例经CECT诊断的囊性肾肿块患者行CEUS并作Bosniak分级,以最终组织病理学和临床随访为参考标准,评估CEUS和CECT的内部效度及两者一致性。

诊断标准与关键数值

  • CEUS:敏感度100%,阴性预测值100%,特异度73.9%,阳性预测值73.9%。
  • CECT:敏感度88.2%,阴性预测值83.3%,特异度87%,阳性预测值90.9%。
  • CEUS与最终诊断一致性K=0.71,CECT与最终诊断一致性K=0.75。
  • CEUS与CECT之间一致性K=0.66,29例(72.5%)结果一致。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Contrast-enhanced ultrasound (CEUS) allows excellent delineation of perfusion in septa and nodules without exposure to ionizing radiation or nephrotoxic contrast media. The aim of our study was to evaluate the role of CEUS for the assessment of cystic renal masses and compare its diagnostic performance with that of CECT.

METHODS: Exactly 40 patients diagnosed to have cystic renal masses on CECT scan were prospectively evaluated with CEUS and were assigned a Bosniak class. Based on results of final histopathology and clinical follow-up, internal validity of both CEUS and CECT was evaluated, including agreement between these two modalities.

RESULTS: Out of the 40 patients (mean size 3.1 ± 2.5 cm), 23 patients had benign lesions and 17 patients had malignant lesions. For CEUS, the sensitivity and negative predictive value was 100%, the specificity and positive predictive value was 73.9%. For CECT, the sensitivity and negative predictive value were 88.2 and 83.3%, respectively, whereas the specificity and positive predictive value was 87 and 90.9%, respectively. Both imaging modalities had similar accuracy with fair to good agreement with the final diagnosis (Κ = 0.71 and 0.75 for CEUS and CECT, respectively). Concordance between CEUS and CECT was seen in 29 patients (72.5%) with fair agreement between the two modalities (K = 0.66).

CONCLUSION: CEUS has comparable accuracy with CECT and could be used as screening modality to rule out the presence of complex cystic renal masses without exposure of nephrotoxic contrast media and ionizing radiation.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Das CJ, Agarwal K, Sharma S, et al. Role of Contrast-Enhanced Ultrasound in Evaluation of Cystic Renal Mass. J Ultrasound Med. 2023. PMID: 37676901. doi:10.1002/jum.16328

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。