文献速递腹部技术与安全CT

利用基于深度学习的图像转换改善肝细胞癌患者CT重建算法的影像组学可重复性

Improving radiomics reproducibility using deep learning-based image conversion of CT reconstruction algorithms in hepatocellular carcinoma patients.
PubMed 文献 · Eur Radiol · 2023-09-01

本研究纳入78例肝细胞癌患者,行四期肝脏CT并分别用滤波反投影和ADMIRE重建,以门静脉期图像训练卷积神经网络实现两种重建算法图像相互转换。测试组30例中,转换后影像组学特征可重复比例(CCC≥0.85)较原始算法间比较明显提高。结论认为基于CNN的图像转换可改善肝细胞癌影像组学可重复性。

要点

  • 原始FBP与原始ADMIRE间可重复特征比例仅32.9%–43.8%,跨重建算法直接比较影像组学特征稳定性有限。
  • 经CNN转换后,FBP与转换FBP间可重复特征比例升至71.0%–83.9%,ADMIRE与转换ADMIRE间升至68.1%–82.1%。
  • 转换后CCC由原始算法间的0.65–0.69提高至0.87–0.92,提示图像转换可提升特征可重复性。

核心结论

  • 基于CNN的CT重建算法间图像转换改善了肝细胞癌影像组学特征的可重复性。

研究设计与样本

  • 本研究纳入78例肝细胞癌患者,行四期肝脏CT(平扫、晚动脉期、门静脉期、延迟期),分别用FBP和ADMIRE重建。以门静脉期图像训练CNN模型实现FBP与ADMIRE图像相互转换,晚动脉期、门静脉期和延迟期图像用于验证和测试;用半自动分割工具提取影像组学特征,以一致性相关系数(CCC)评价可重复性。

诊断标准与关键数值

  • 测试组30例中,原始FBP vs 原始ADMIRE的可重复特征比例(CCC≥0.85):晚动脉期32.9%(524/1595)、门静脉期35.9%(573/1595)、延迟期43.8%(699/1595),CCC分别为0.65、0.65、0.69;原始FBP vs 转换FBP:晚动脉期83.9%(1339/1595)、门静脉期71.0%(1133/1595)、延迟期79.7%(1271/1595),CCC分别为0.92、0.89、0.90;原始ADMIRE vs 转换ADMIRE:晚动脉期68.1%(1086/1595)、门静脉期82.1%(1309/1595)、延迟期76.2%(1216/1595),CCC分别为0.87、0.91、0.89。

临床应用与阅片要点

  • 作者指出该CNN图像转换技术显著改善肝细胞癌影像组学特征可重复性,并强调其在提升肝细胞癌影像组学研究方面的潜力。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: CT reconstruction algorithms affect radiomics reproducibility. In this study, we evaluate the effect of deep learning-based image conversion on CT reconstruction algorithms.

METHODS: This study included 78 hepatocellular carcinoma (HCC) patients who underwent four-phase liver CTs comprising non-contrast, late arterial (LAP), portal venous (PVP), and delayed phase (DP), reconstructed using both filtered back projection (FBP) and advanced modeled iterative reconstruction (ADMIRE). PVP images were used to train a convolutional neural network (CNN) model to convert images from FBP to ADMIRE and vice versa. LAP, PVP, and DP images were used for validation and testing. Radiomic features were extracted for each patient with a semi-automatic segmentation tool. We used concordance correlation coefficients (CCCs) to evaluate the radiomics reproducibility for original FBP (oFBP) vs. original ADMIRE (oADMIRE), oFBP vs. converted FBP (cFBP), and oADMIRE vs. converted ADMIRE (cADMIRE).

RESULTS: In the test group including 30 patients, the CCC and proportion of reproducible features (CCC ≥ 0.85) for oFBP vs. oADMIRE were 0.65 and 32.9% (524/1595) for LAP, 0.65 and 35.9% (573/1595) for PVP, and 0.69 and 43.8% (699/1595) for DP. For oFBP vs. cFBP, the values increased to 0.92 and 83.9% (1339/1595) for LAP, 0.89 and 71.0% (1133/1595) for PVP, and 0.90 and 79.7% (1271/1595) for DP. Similarly, for oADMIRE vs. cADMIRE, the values increased to 0.87 and 68.1% (1086/1595) for LAP, 0.91 and 82.1% (1309/1595) for PVP, and 0.89 and 76.2% (1216/1595) for DP.

CONCLUSIONS: CNN-based image conversion between CT reconstruction algorithms improved the radiomics reproducibility of HCCs.

CLINICAL RELEVANCE STATEMENT: This study demonstrates that using a CNN-based image conversion technique significantly improves the reproducibility of radiomic features in HCCs, highlighting its potential for enhancing radiomics research in HCC patients.

KEY POINTS: Radiomics reproducibility of HCC was improved via CNN-based image conversion between two different CT reconstruction algorithms. This is the first clinical study to demonstrate improvements across a range of radiomic features in HCC patients. This study promotes the reproducibility and generalizability of different CT reconstruction algorithms in radiomics research.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Lee H, Chang W, Kim HY, et al. Improving radiomics reproducibility using deep learning-based image conversion of CT reconstruction algorithms in hepatocellular carcinoma patients. Eur Radiol. 2023. PMID: 37656175. doi:10.1007/s00330-023-10135-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。