儿童与成人门静脉形态学的系统评价与荟萃分析:在正常与异常表现之间划界
该系统评价与荟萃分析纳入122项研究、11637名受试者,汇总正常门静脉主干直径均值为10.09 mm(95%CI 9.56-10.62),儿童为6.60 mm、成人为10.72 mm;CT测值(13.28 mm)显著大于MRI(10.50 mm)和超声(9.81 mm)。作者提出儿童正常门静脉直径上限阈值为8 mm,而成人在CT上超过13 mm阈值。
要点
- 成人门静脉主干直径汇总均值为10.72 mm(95%CI 10.25-11.19),儿童为6.60 mm(95%CI 5.38-7.82)。
- CT测得的门静脉直径(13.28 mm)显著大于MRI(10.50 mm)和超声(9.81 mm)。
- 作者提出儿童正常门静脉直径诊断上限阈值为8 mm。
核心结论
- 研究旨在提高对儿童和成人门静脉解剖的理解,尤其与肝脏手术干预相关;超声测值接近汇总的儿童和成人门静脉直径均值,CT测值显著超过成人既有的13 mm阈值,作者提出儿童正常门静脉直径诊断上限阈值为8 mm。
研究设计与样本
- 系统评价与荟萃分析,遵循PRISMA指南并在PROSPERO注册,检索MEDLINE、EMBASE、SCOPUS和Web of Science数据库至2020年5月并更新至2023年5月,纳入122项研究共11637名受试者,使用AQUA工具评估纳入研究质量,并按地理位置、性别、年龄和成像方式做亚组分析。
诊断标准与关键数值
- 门静脉主干直径汇总均值为10.09 mm(95%CI 9.56-10.62);儿童为6.60 mm(95%CI 5.38-7.82),成人为10.72 mm(95%CI 10.25-11.19)。CT测值为13.28 mm(95%CI 11.71-14.84),MRI为10.50 mm(95%CI 9.35-11.66),超声为9.81 mm(95%CI 9.47-10.16)。左门静脉直径为8.27 mm(95%CI 6.78-9.77),右门静脉直径为8.33 mm(95%CI 6.70-9.95)。成人门静脉长度均值为48.63 mm(95%CI 35.63-61.64),门静脉主干横截面积均值为1.09 cm2。作者提出儿童正常门静脉直径诊断上限阈值为8 mm;成人CT测值显著超过既有的13 mm阈值。
临床应用与阅片要点
- 超声测值接近汇总的儿童和成人门静脉直径均值;CT测值显著超过成人既有的13 mm阈值;作者提出儿童正常门静脉直径诊断上限阈值为8 mm。门静脉直径从门静脉汇合处向分叉处减小,但原文报告该变化无统计学显著性。
局限性
- 原文结论中门静脉直径从门静脉汇合处向分叉处减小虽未达统计学显著,但原文未将其列为局限性。
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The morphometry of the hepatic portal vein is of clinical importance, particularly in pre-operative assessments, surgical management, and diagnoses of liver conditions. This systematic review and meta-analysis aimed to characterize the morphometry of the normal portal vein in both pediatric and adult patients.
METHODS: The study, conducted using the PRISMA guidelines and registered with PROSPERO, utilized the MEDLINE, EMBASE, SCOPUS and Web of Science databases up to May 2020, and updated to May 2023. All studies reporting extractable data on diameter, length, and cross-sectional area (CSA) of the main, left, and right portal veins (PV, LPV, RPV, respectively) were included. The AQUA Tool was used to assess the quality of the included studies. Data analysis included subgroup analyses based on geographical location, sex, age, and imaging modality.
RESULTS: A total of 122 studies with 11,637 subjects were eligible for inclusion. Overall, the pooled mean diameter of the PV (PVD) was 10.09 mm (95% CI: 9.56-10.62). Significant differences in diameter were found between pediatric (6.60 mm; 95% CI: 5.38-7.82) and adult (10.72 mm; 95% CI: 10.25-11.19) subjects. Additionally, there was a significantly larger PVD measurement from computed tomography (CT) than other imaging modalities: CT, 13.28 mm (95% CI: 11.71-14.84); magnetic resonance imaging (MRI), 10.50 mm (95% CI: 9.35-11.66) and ultrasound (US), 9.81 mm (95% CI: 9.47-10.16). The mean diameters of the LPV and RPV were 8.27 mm (95% CI: 6.78-9.77) and 8.33 mm (95% CI: 6.70-9.95), respectively. Mean PV length in adults is 48.63 mm (95% CI: 35.63-61.64). Mean CSA of the PV was 1.09 cm2.
CONCLUSIONS: The study obtained aim to improve the understanding of portal vein anatomy, especially with relevance to surgical interventions of the liver in both pediatric and adult patients. Measurements from ultrasound imaging closely approximates the generated pooled PVD mean for pediatric and adult patients. CT imaging, however, significantly exceeded the established 13 mm threshold for adults. For pediatric patients, a threshold of 8 mm is proposed as a diagnostic upper limit for a normal PVD. Although not significant, the PVD decreased from the portal confluence towards its bifurcation.
引用
- Chau P, Yoon JS, Moses D, et al. A systematic review and meta-analysis of portal vein morphometry in pediatric and adult populations: Drawing the line between normal and abnormal findings. Eur J Radiol. 2023. PMID: 37742371. doi:10.1016/j.ejrad.2023.111016
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。