基于超声造影图像的影像组学用于诊断胰腺浆液性囊腺瘤
该回顾性研究纳入2015年5月至2022年8月在中国人民解放军医院经病理确诊并接受超声造影检查的113例胰腺囊性肿瘤患者,提取超声造影图像感兴趣区影像组学特征构建支持向量机模型,并与超声造影模型及联合模型比较。影像组学模型在训练集和测试集的AUC分别为0.875和0.862,敏感度和特异度分别为训练集81.5%和86.5%、测试集81.8%和91.3%,在区分胰腺浆液性囊腺瘤与其他胰腺囊性肿瘤方面表现出良好的鉴别诊断性能。
要点
- 基于超声造影图像的影像组学模型在测试集区分胰腺浆液性囊腺瘤与其他胰腺囊性肿瘤的AUC为0.862。
- 影像组学模型测试集敏感度81.8%、特异度91.3%,高于或相当于超声造影模型和联合模型。
- 研究纳入经病理确诊的胰腺囊性肿瘤113例,训练集79例、测试集34例。
核心结论
- 基于超声造影图像的影像组学模型在区分胰腺浆液性囊腺瘤与其他胰腺囊性肿瘤方面具有良好的鉴别诊断性能,可能有助于探索个体化管理策略。
研究设计与样本
- 回顾性研究,纳入2015年5月至2022年8月在中国人民解放军医院经病理确诊且接受超声造影检查的胰腺囊性肿瘤患者113例,随机分为训练集79例和测试集34例;从超声造影图像感兴趣区提取影像组学特征,采用支持向量机算法构建影像组学模型,并基于超声造影图像特征用逻辑回归构建超声造影模型和联合模型;以AUC、敏感度、特异度和决策曲线分析评价最优模型的性能和临床效用。
诊断标准与关键数值
- 影像组学模型训练集AUC为0.875,测试集AUC为0.862。
- 影像组学模型训练集敏感度81.5%、特异度86.5%,测试集敏感度81.8%、特异度91.3%。
- 影像组学模型的敏感度和特异度高于或相当于超声造影模型和联合模型。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The purpose of the study was to develop and validate a radiomics model by using contrast-enhanced ultrasound (CEUS) data for pre-operative differential diagnosis of pancreatic cystic neoplasms (PCNs), especially pancreatic serous cystadenoma (SCA).
METHODS: Patients with pathologically confirmed PCNs who underwent CEUS examination at Chinese PLA hospital from May 2015 to August 2022 were retrospectively collected. Radiomic features were extracted from the regions of interest, which were obtained based on CEUS images. A support vector machine algorithm was used to construct a radiomics model. Moreover, based on the CEUS image features, the CEUS and the combined models were constructed using logistic regression. The performance and clinical utility of the optimal model were evaluated by area under the receiver operating characteristic curve (AUC), sensitivity, specificity and decision curve analysis.
RESULTS: A total of 113 patients were randomly split into the training (n = 79) and test cohorts (n = 34). These patients were pathologically diagnosed with SCA, mucinous cystadenoma, intraductal papillary mucinous neoplasm and solid-pseudopapillary tumor. The radiomics model achieved an AUC of 0.875 and 0.862 in the training and test cohorts, respectively. The sensitivity and specificity of the radiomics model were 81.5% and 86.5% in the training cohort and 81.8% and 91.3% in the test cohort, respectively, which were higher than or comparable with that of the CEUS model and the combined model.
CONCLUSION: The radiomics model based on CEUS images had a favorable differential diagnostic performance in distinguishing SCA from other PCNs, which may be beneficial for the exploration of personalized management strategies.
引用
- Zhang Y, Yao J, Liu F, et al. Radiomics Based on Contrast-Enhanced Ultrasound Images for Diagnosis of Pancreatic Serous Cystadenoma. Ultrasound Med Biol. 2023. PMID: 37749013. doi:10.1016/j.ultrasmedbio.2023.08.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。