基于深度学习的碘对比剂增强算法用于低对比剂剂量肝脏CT评估乏血供肝转移瘤

Deep learning-based iodine contrast-augmenting algorithm for low-contrast-dose liver CT to assess hypovascular hepatic metastasis.
PubMed 文献 · Abdom Radiol (NY) · 2023-09-14

回顾性纳入128例接受30%碘对比剂减量门静脉期双能CT肝脏转移瘤监测的患者,比较50-keV虚拟单能图像、模拟120-kVp线性融合图像和深度学习碘对比剂增强算法后处理120-kVp图像。DLICA 120-kVp图像质量与病灶显著性优于其他两种图像,对直径<20 mm病灶的检出优度和灵敏度高于50-keV VMI,总体诊断效能相似。

要点

  • DLICA 120-kVp病灶-肝脏CNR为5.7±3.1,高于50-keV VMI和120-kVp的3.8±2.1。
  • DLICA 120-kVp对直径<20 mm乏血供肝转移瘤的检出优度为0.677,高于50-keV VMI的0.648。
  • DLICA 120-kVp每病灶灵敏度为81.2%,高于50-keV VMI的72.9%。

核心结论

  • 在30%碘对比剂减量门静脉期肝脏CT中,DLICA 120-kVp较50-keV VMI和120-kVp提供更优的病灶显著性和图像质量,对乏血供肝转移瘤的诊断效能与50-keV VMI相似。

研究设计与样本

  • 回顾性研究纳入2019年7月至2022年6月间128例接受30%碘对比剂减量门静脉期对比增强双能CT肝脏转移瘤监测的患者,重建50-keV VMI、模拟120-kVp线性融合图像和DLICA后处理120-kVp图像三种图像,以两位独立放射科医师共识为参考标准。

关键影像表现/征象

  • DLICA 120-kVp病灶-肝脏CNR为5.7±3.1,50-keV VMI为3.8±2.1,120-kVp为3.8±2.1,DLICA 120-kVp更高(p<0.001)。
  • DLICA 120-kVp在所有区域的图像噪声均显著低于50-keV VMI(p<0.001)。
  • DLICA 120-kVp病灶显著性评分为4.0(3.3-4.3),50-keV VMI为3.7(3.0-4.0),120-kVp为3.7(3.0-4.0),DLICA 120-kVp更高(p<0.001)。

诊断标准与关键数值

  • DLICA 120-kVp对直径<20 mm病灶的检出优度为0.677,50-keV VMI为0.648(p=0.007)。
  • DLICA 120-kVp每病灶灵敏度为81.2%,50-keV VMI为72.9%(p<0.001)。
  • 三种算法每病灶特异度无显著差异(p=0.15);三种方法病灶诊断优度无显著差异(p=0.11)。

临床应用与阅片要点

  • 在30%碘对比剂减量门静脉期肝脏CT中,DLICA 120-kVp可提高乏血供肝转移瘤的病灶显著性和图像质量。
  • 对直径<20 mm的乏血供肝转移瘤,DLICA 120-kVp的检出优度和每病灶灵敏度高于50-keV VMI。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To investigate the image quality and diagnostic performance of low-contrast-dose liver CT using a deep learning-based iodine contrast-augmenting algorithm (DLICA) for hypovascular hepatic metastases.

METHODS: This retrospective study included 128 patients who underwent contrast-enhanced dual-energy CT for hepatic metastasis surveillance between July 2019 and June 2022 using a 30% reduced iodine contrast dose in the portal phase. Three image types were reconstructed: 50-keV virtual monoenergetic images (50-keV VMI); linearly blended images simulating 120-kVp images (120-kVp); and post-processed 120-kVp images using DLICA (DLICA 120-kVp). Three reviewers evaluated lesion conspicuity, image contrast, and subjective image noise. We also measured image noise, contrast-to-noise ratios (CNRs), and signal-to-noise ratios (SNRs). The diagnostic performance for hepatic metastases was evaluated using a jackknife alternative free-response receiver operating characteristic method with the consensus of two independent radiologists as the reference standard.

RESULTS: DLICA 120-kVp demonstrated significantly higher CNR of lesions to liver (5.7 ± 3.1 vs. 3.8 ± 2.1 vs. 3.8 ± 2.1) and higher SNR compared with 50-keV VMI and 120-kVp (p < 0.001 for all). DLICA 120-kVp had significantly lower image noise than 50-kVp VMI for all regions (p < 0.001 for all). DLICA 120-kVp also exhibited superior lesion conspicuity (4.0 [3.3-4.3] vs. 3.7 [3.0-4.0] vs. 3.7 [3.0-4.0]), higher image contrast, and lower subjective image noise compared with 50-keV VMI and 120-kVp (p < 0.001 for all). Although there was no significant difference in the figure of merit for lesion diagnosis among the three methods (p = 0.11), DLICA 120-kVp had a significantly higher figure of merit for lesions with a diameter < 20 mm than 50-keV VMI (0.677 vs. 0.648, p = 0.007). On a per-lesion basis, DLICA 120-kVp also demonstrated higher sensitivity than the 50-keV VMI (81.2% vs. 72.9%, p < 0.001). The specificities per lesion were not significantly different among the three algorithms (p = 0.15).

CONCLUSION: DLICA at 120-kVp provided superior lesion conspicuity and image quality and similar diagnostic performance for hypovascular hepatic metastases compared with 50-keV VMI.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。