现行与改良CEUS LI-RADS在非肝细胞癌恶性肿瘤诊断中的效能
该回顾性研究纳入131个经病理证实的非肝细胞癌恶性肿瘤病灶,评估CEUS LI-RADS(2017版)LR-M的诊断效能,并探讨将早期廓清阈值改为<45秒或显著廓清改为<5分钟对LR-M敏感度的影响。现行LR-M诊断非肝细胞癌恶性肿瘤的敏感度为84.7%,早期廓清<45秒时敏感度为80.9%,显著廓清<5分钟时敏感度为72.5%。
要点
- 现行CEUS LR-M诊断非肝细胞癌恶性肿瘤的敏感度为84.7%。
- 将早期廓清阈值提前至<45秒,LR-M敏感度为80.9%。
- 将显著廓清限定在5分钟内,LR-M敏感度降至72.5%。
核心结论
- CEUS LR-M诊断非肝细胞癌恶性肿瘤具有较高敏感度;对于表现为非环状动脉期高增强伴早期廓清且非肝细胞癌恶性肿瘤的LR-M结节,将早期廓清时间提前至<45秒对LR-M敏感度的影响小于将显著廓清限定在5分钟内。
研究设计与样本
- 回顾性研究,最终纳入131个经病理证实的非肝细胞癌恶性肿瘤病灶,包括71个肝内胆管癌、26个混合型肝细胞-胆管细胞癌、29个转移瘤和5个其他非肝细胞癌恶性肿瘤;两名放射科医师独立判读主要CEUS特征并对肝脏病灶进行分类,采用配对χ2检验比较现行与改良CEUS LR-M的敏感度,采用Cohen's κ比较LI-RADS分类的阅片者间一致性。
诊断标准与关键数值
- 病灶LI-RADS分类为LR-M、LR-5、LR-4、LR-3的数目分别为111、18、1、1;LI-RADS分类的阅片者间一致性κ值为0.59;现行CEUS LR-M诊断非肝细胞癌恶性肿瘤的敏感度为84.7%;将早期廓清时间调整为<45秒时LR-M敏感度为80.9%;将显著廓清时间调整为<5分钟时LR-M敏感度为72.5%。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The high proportion of HCC in CEUS LR-M decreases the sensitivity of LR-5 for the diagnosis of HCC. However, when modifying LR-M criteria to further improve the sensitivity of LR-5, it is also important not to compromise the diagnostic performance (especially sensitivity) of LR-M for non-hepatocellular carcinoma malignancies (non-HCCMs). The purpose of this study was to evaluate the diagnostic performance of CEUS LI-RADS (2017 version) for non-HCCMs and to explore the impact of modified CEUS LI-RADS on the diagnostic performance of LR-M.
METHODS: In this retrospective study, patients with pathologically confirmed non-HCCMs were evaluated. Two radiologists independently interpreted the major CEUS features and categorized the liver lesions. New LR-M criteria were applied: early washout (< 45 s) or marked washout (< 5 min). The sensitivity values of the current and modified CEUS LR-M were assessed and then compared using a paired χ2 test. Cohen's κ was used to compare the inter-reader agreement of the LI-RADS categories.
RESULTS: A total of 131 non-HCCMs were ultimately selected, including 71 intrahepatic cholangiocarcinomas, 26 combined hepatocellular cholangiocarcinomas, 29 metastases, and 5 other non-HCCMs. The numbers of LR-M, LR-5, LR-4, and LR-3 in liver lesions were 111, 18, 1, and 1, respectively. The inter-reader agreement of the LI-RADS categories for non-HCCMs was 0.59. The sensitivity of the current CEUS LR-M in diagnosing non-HCCMs was 84.7%. By adjusting the early washout time to < 45 s, the sensitivity of LR-M was 80.9%. By adjusting the marked washout time within 5 min, the sensitivity of LR-M was 72.5%.
CONCLUSION: CEUS LR-M has high sensitivity in diagnosing non-HCCMs. For LR-M nodules with nonrim arterial phase hyperenhancement and early washout, advancing the time of early washout to < 45 s has a minimal impact on the sensitivity of LR-M in diagnosing non-HCCMs compared to the condition of increasing the marked washout within 5 min.
引用
- Wen R, Huang F, Lin P, et al. Performance of current versus modified CEUS LI-RADS in the diagnosis of non-hepatocellular carcinoma malignancies. Abdom Radiol (NY). 2023. PMID: 37726380. doi:10.1007/s00261-023-04043-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。