B-flow/时空图像相关M型超声与超声造影/微泡成像定量评估螺旋动脉扩张性及胎盘绒毛间隙灌注:一项螺旋动脉重塑受损灵长类模型早孕期研究

B-Flow/Spatiotemporal Image Correlation M-Mode and Contrast-Enhanced/Microbubble Ultrasonography Quantification of Spiral Artery Distensibility and Placental Intervillous Perfusion in the First Trimester in a Primate Model of Impaired Spiral Artery Remodeling.
PubMed 文献 · Ultrasound Med Biol · 2023-09-24

在早孕期接受雌二醇处理以抑制螺旋动脉重塑的狒狒模型中,B-flow/时空图像相关M型超声显示螺旋动脉扩张性降低26%(p=0.03),血流量降低55%(p=0.059);而超声造影/微泡成像测得的胎盘绒毛间隙血流率和视频强度平台水平未改变。结果表明B-flow/时空图像相关M型超声可无创检测螺旋动脉扩张性降低。

要点

  • B-flow/STIC M型超声可无创定量螺旋动脉管径随心动周期的变化,反映血管扩张性。
  • 螺旋动脉重塑受抑制的狒狒中,螺旋动脉扩张性降低26%(p=0.03)。
  • 超声造影/微泡成像测得的胎盘绒毛间隙灌注在螺旋动脉重塑受抑制时未见改变。

核心结论

  • B-flow/STIC M型超声可无创检测螺旋动脉重塑受损灵长类模型早孕期螺旋动脉扩张性及功能降低,是判断该缺陷是否同样见于人类不良妊娠早期的第一步。

研究设计与样本

  • 在狒狒早孕期,对未处理或接受雌二醇处理以抑制螺旋动脉重塑的动物行B-flow/STIC M型超声和超声造影/微泡成像检查。

关键影像表现/征象

  • B-flow/STIC M型超声定量螺旋动脉扩张性(收缩期管腔直径减舒张期直径)和血流量。
  • 螺旋动脉重塑受抑制的狒狒扩张性降低26%(p=0.03)。
  • 螺旋动脉重塑受抑制的狒狒血流量降低55%(p=0.059)。
  • 超声造影/微泡成像显示胎盘绒毛间隙血流率和视频强度平台水平未改变。

局限性

  • 本研究为灵长类模型,B-flow/STIC M型超声能否在人类不良妊娠早期检测出类似的螺旋动脉重塑缺陷尚需进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: During early human pregnancy, placental trophoblasts remodel spiral arteries into distensible low-resistance vessels to promote placental perfusion. We have established a model of impaired spiral artery remodeling (SAR) by elevating estradiol levels in the first trimester of baboon pregnancy. In the present study, B-flow/spatiotemporal image correlation (STIC) M-mode ultrasonography, a non-Doppler technology for sharp rendering of vessel dimensions, was used to determine whether spiral artery distensibility was altered in SAR-suppressed baboons. Contrast-enhanced ultrasound/microbubble imaging was also performed to determine whether it detected changes in placenta intervillous space perfusion in SAR-suppressed baboons.

METHODS: The two imaging procedures were performed in the first trimester in baboons not treated or treated with estradiol to suppress SAR.

RESULTS: Spiral artery distensibility, that is, luminal diameter at systole minus diameter at diastole, and volume flow as quantified by B-flow/STIC M-mode were 26% (p = 0.03) and 55% (p = 0.059) lower, respectively, in SAR-suppressed baboons. However, placental intervillous space flow rate and video intensity plateau levels reflecting blood perfusion, quantified by contrast-enhanced ultrasound/microbubble imaging, were unaltered in SAR-suppressed baboons.

CONCLUSION: The results indicate that B-flow/STIC M-mode ultrasonography provides a non-invasive method to detect reduced distensibility and, thus, function of spiral arteries across the cardiac cycle in the first trimester in a primate model of impaired SAR. This study represents a first step in determining whether B-flow/STIC M-mode detects a similar defect in SAR early in adverse human pregnancy. This would provide an avenue to develop therapeutic modalities to prevent the devastating consequences of impaired SAR.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Turan OM, Babischkin JS, Aberdeen GW, et al. B-Flow/Spatiotemporal Image Correlation M-Mode and Contrast-Enhanced/Microbubble Ultrasonography Quantification of Spiral Artery Distensibility and Placental Intervillous Perfusion in the First Trimester in a Primate Model of Impaired Spiral Artery Remodeling. Ultrasound Med Biol. 2023. PMID: 37749012. doi:10.1016/j.ultrasmedbio.2023.08.021