本研究纳入85例患者共166枚支架,对比超分辨率深度学习重建PIQE与基于模型的迭代重建FIRST对支架内再狭窄的检测效能。PIQE图像质量评分更高(4.2±1.1 vs 2.7±1.2,p<0.05),特异度和准确度均优于FIRST(p<0.05),在支架直径<3.0 mm时差异尤为明显。结论认为PIQE对支架内再狭窄可提供更优的图像质量和诊断准确度。

要点

  • PIQE图像质量评分高于FIRST(4.2±1.1 vs 2.7±1.2,p<0.05)。
  • PIQE检测支架内再狭窄的特异度和准确度均优于FIRST(p<0.05)。
  • 支架直径<3.0 mm时PIQE与FIRST的诊断差异尤为明显。

核心结论

  • PIQE对支架内再狭窄可提供优于FIRST的图像质量和诊断准确度,即使支架直径<3.0 mm亦如此。

研究设计与样本

  • 可行性研究,纳入2019—2021年经皮冠状动脉介入治疗置入冠状动脉支架后3个月内行CT和侵入性冠状动脉造影的85例连续患者共166枚支架。

关键影像表现/征象

  • PIQE的管腔半高全宽大于FIRST。
  • PIQE的支架支柱厚度小于FIRST。

诊断标准与关键数值

  • 支架内再狭窄定义为侵入性冠状动脉造影上直径狭窄百分比≥50%。
  • PIQE检测支架内再狭窄的特异度和准确度均优于FIRST(p<0.05),支架直径<3.0 mm时差异尤为明显。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Evaluation of in-stent restenosis (ISR), especially for small stents, remains challenging during computed tomography (CT) angiography. We used deep learning reconstruction to quantify stent strut thickness and lumen vessel diameter at the stent and compared it with values obtained using conventional reconstruction strategies.

METHODS: We examined 166 stents in 85 consecutive patients who underwent CT and invasive coronary angiography (ICA) within 3 months of each other from 2019-2021 after percutaneous coronary intervention with coronary stent placement. The presence of ISR was defined as percent diameter stenosis ≥ 50% on ICA. We compared a super-resolution deep learning reconstruction, Precise IQ Engine (PIQE), and a model-based iterative reconstruction, Forward projected model-based Iterative Reconstruction SoluTion (FIRST). All images were reconstructed using PIQE and FIRST and assessed by two blinded cardiovascular radiographers.

RESULTS: PIQE had a larger full width at half maximum of the lumen and smaller strut than FIRST. The image quality score in PIQE was higher than that in FIRST (4.2 ± 1.1 versus 2.7 ± 1.2, p < 0.05). In addition, the specificity and accuracy of ISR detection were better in PIQE than in FIRST (p < 0.05 for both), with particularly pronounced differences for stent diameters < 3.0 mm.

CONCLUSION: PIQE provides superior image quality and diagnostic accuracy for ISR, even with stents measuring < 3.0 mm in diameter.

CLINICAL RELEVANCE STATEMENT: With improvements in the diagnostic accuracy of in-stent stenosis, CT angiography could become a gatekeeper for ICA in post-stenting cases, obviating ICA in many patients after recent stenting with infrequent ISR and allowing non-invasive ISR detection in the late phase.

KEY POINTS: • Despite CT technology advancements, evaluating in-stent stenosis severity, especially in small-diameter stents, remains challenging. • Compared with conventional methods, the Precise IQ Engine uses deep learning to improve spatial resolution. • Improved diagnostic accuracy of CT angiography helps avoid invasive coronary angiography after coronary artery stenting.