文献速递胸部骨肌技术与安全CT

结合深度学习与影像组学从低剂量胸部CT自动客观全面评估骨密度

Combining Deep Learning and Radiomics for Automated, Objective, Comprehensive Bone Mineral Density Assessment From Low-Dose Chest Computed Tomography.
PubMed 文献 · Acad Radiol · 2023-09-19

本研究纳入442例同时接受低剂量胸部CT和定量CT检查的参与者,随机分为训练、内部测试和外部测试队列,训练VB-Net自动分割胸椎松质骨并构建影像组学模型评估骨密度。自动分割模型在内部和外部测试队列的Dice系数分别为0.988±0.014和0.939±0.034;自动分割与手动分割模型在鉴别骨密度正常与异常(一级模型)及鉴别骨量减少与骨质疏松(二级模型)时AUC相当,差异均无统计学意义。结论认为全自动分割联合影像组学流程可用于低剂量胸部CT的机会性骨密度筛查。

要点

  • 自动分割胸椎松质骨Dice系数内部0.988±0.014、外部0.939±0.034,分割精度高。
  • 一级模型自动分割AUC内部0.985、外部0.965,与手动分割相当(P=0.080、P=0.724)。
  • 二级模型自动分割AUC内部0.933、外部0.907,与手动分割相当(P=0.794、P=0.805)。

核心结论

  • 基于自动分割胸椎松质骨和影像组学分析的全自动流程可用于低剂量胸部CT的机会性骨密度筛查。

研究设计与样本

  • 研究纳入442例同时接受低剂量胸部CT和定量CT检查的参与者,随机分配至训练、内部测试和外部测试队列,使用VB-Net训练胸椎松质骨自动分割模型,并以定量CT为参考标准分别基于自动分割和手动分割构建影像组学骨密度预测模型。

诊断标准与关键数值

  • 胸椎松质骨自动分割模型Dice系数内部测试队列0.988±0.014、外部测试队列0.939±0.034;一级模型(鉴别骨密度正常与异常)自动分割AUC内部0.985 vs 手动分割0.946(P=0.080)、外部0.965 vs 0.955(P=0.724);二级模型(鉴别骨量减少与骨质疏松)自动分割AUC内部0.933 vs 手动分割0.920(P=0.794)、外部0.907 vs 0.892(P=0.805)。

临床应用与阅片要点

  • 作者认为基于自动分割胸椎松质骨和影像组学分析的全自动流程可用于低剂量胸部CT的机会性骨密度筛查。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To develop an intelligent diagnostic model for osteoporosis screening based on low-dose chest computed tomography (LDCT). The model incorporates automatic deep-learning thoracic vertebrae of cancellous bone (TVCB) segmentation model and radiomics analysis.

MATERIALS AND METHODS: A total of 442 participants who underwent both LDCT and quantitative computed tomography (QCT) examinations were enrolled and were randomly allocated to the training, internal testing, and external testing cohorts. The TVCB automatic segmentation model was trained using VB-Net. The accuracy of the segmentation was evaluated using the Dice coefficient. Predictive models for assessing bone mineral density (BMD) were constructed utilizing radiomics analysis based on automatic segmentation (ASeg model) and manual segmentation (MSeg model), respectively. The BMD predictive model based on ASeg and MSeg included the identification of normal and abnormal BMD (first-level model), and osteopenia and osteoporosis (second-level model). The diagnostic performance of the radiomics models were evaluated using the area under the curve (AUC), sensitivity and specificity.

RESULTS: The Dice coefficients of the TVCB segmentation model in the internal and external testing cohorts were found to be 0.988 ± 0.014 and 0.939 ± 0.034, respectively. In the first-level model, the AUC of the ASeg model exhibited comparable performance to that of the MSeg model for both the internal (0.985 vs. 0.946, P = 0.080) and external (0.965 vs. 0.955, P = 0.724) testing cohorts. Similarly, in the second-level model, the AUC of the ASeg model was found to be comparable to that of the MSeg model for both the internal (0.933 vs. 0.920, P = 0.794) and external (0.907 vs. 0.892, P = 0.805) testing cohorts.

CONCLUSION: A fully automated pipeline for TVCB segmentation and BMD assessment with radiomics analysis can be used for opportunistic BMD screening in chest LDCT.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Wang S, Tong X, Fan Y, et al. Combining Deep Learning and Radiomics for Automated, Objective, Comprehensive Bone Mineral Density Assessment From Low-Dose Chest Computed Tomography. Acad Radiol. 2023. PMID: 37730494. doi:10.1016/j.acra.2023.08.030

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。