文献速递胸部外周血管CT

多能CT评估慢性血栓栓塞性肺动脉高压低灌注的空间范围

Mapping the Spatial Extent of Hypoperfusion in Chronic Thromboembolic Pulmonary Hypertension Using Multienergy CT.
PubMed 文献 · Radiol Cardiothorac Imaging · 2023-08-10

本研究回顾性纳入51例慢性血栓栓塞性肺动脉高压患者与110例无肺血管异常影像的对照,利用深度学习肺段分割自动量化多能CT血管成像上的低灌注肺体积。全局低灌注肺体积区分患者的AUC为0.84,10%阈值下敏感度90%、准确率72%、特异度64%,并与肺血管阻力及术后变化相关。该方法可能有助于临床评估,尤其在节段性疾病患者中。

要点

  • 全局低灌注肺体积以10%为阈值区分慢性血栓栓塞性肺动脉高压与对照的AUC为0.84。
  • 10%阈值下敏感度90%、准确率72%、特异度64%。
  • 全局低灌注肺体积与肺血管阻力中度相关(ρ=0.67,P<.001)。

核心结论

  • 自动化量化慢性血栓栓塞性肺动脉高压患者的低灌注区域可在临床多能CT检查上完成,可能有助于临床评估,尤其在节段性疾病患者中。

研究设计与样本

  • 回顾性研究,纳入2018年1月至2020年12月间51例慢性血栓栓塞性肺动脉高压患者(平均年龄47岁±17,27例女性)与110例无提示肺血管异常影像表现的对照(平均年龄51岁±16,81例女性)。
  • 采用深度学习肺叶肺段分割自动分离肺实质碘值,以低碘浓度 delineate 低灌注区域并计算低灌注肺体积。
  • 评估受试者工作特征曲线、与术前及术后有创血流动力学变化的相关性,并与两位专家阅片者肺叶低灌注视觉评估进行比较。

诊断标准与关键数值

  • 全局低灌注肺体积区分慢性血栓栓塞性肺动脉高压与对照的AUC为0.84。
  • 10%低灌注肺体积阈值下敏感度90%、准确率72%、特异度64%。
  • 全局低灌注肺体积与影像检查时血流动力学严重程度(肺血管阻力)中度相关(ρ=0.67,P<.001),与手术治疗后肺血管阻力变化相关(∆PVR,ρ=-0.61,P<.001)。
  • 手术分类为节段性疾病的患者中,全局低灌注肺体积与术前肺血管阻力相关(ρ=0.81),与术后∆PVR相关(ρ=-0.70)。
  • 肺叶低灌注肺体积与专家阅片者肺叶评估中度相关(阅片者1 ρ=0.71;阅片者2 ρ=0.67)。

临床应用与阅片要点

  • 自动化低灌注肺体积量化可在临床多能CT检查上完成,可能有助于慢性血栓栓塞性肺动脉高压的临床评估,尤其在节段性疾病患者中。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess if a novel automated method to spatially delineate and quantify the extent of hypoperfusion on multienergy CT angiograms can aid the evaluation of chronic thromboembolic pulmonary hypertension (CTEPH) disease severity.

MATERIALS AND METHODS: Multienergy CT angiograms obtained between January 2018 and December 2020 in 51 patients with CTEPH (mean age, 47 years ± 17 [SD]; 27 women) were retrospectively compared with those in 110 controls with no imaging findings suggestive of pulmonary vascular abnormalities (mean age, 51 years ± 16; 81 women). Parenchymal iodine values were automatically isolated using deep learning lobar lung segmentations. Low iodine concentration was used to delineate areas of hypoperfusion and calculate hypoperfused lung volume (HLV). Receiver operating characteristic curves, correlations with preoperative and postoperative changes in invasive hemodynamics, and comparison with visual assessment of lobar hypoperfusion by two expert readers were evaluated.

RESULTS: Global HLV correctly separated patients with CTEPH from controls (area under the receiver operating characteristic curve = 0.84; 10% HLV cutoff: 90% sensitivity, 72% accuracy, and 64% specificity) and correlated moderately with hemodynamic severity at time of imaging (pulmonary vascular resistance [PVR], ρ = 0.67; P < .001) and change after surgical treatment (∆PVR, ρ = -0.61; P < .001). In patients surgically classified as having segmental disease, global HLV correlated with preoperative PVR (ρ = 0.81) and postoperative ∆PVR (ρ = -0.70). Lobar HLV correlated moderately with expert reader lobar assessment (ρHLV = 0.71 for reader 1; ρHLV = 0.67 for reader 2).

CONCLUSION: Automated quantification of hypoperfused areas in patients with CTEPH can be performed from clinical multienergy CT examinations and may aid clinical evaluation, particularly in patients with segmental-level disease.Keywords: CT-Spectral Imaging (Multienergy), Pulmonary, Pulmonary Arteries, Embolism/Thrombosis, Chronic Thromboembolic Pulmonary Hypertension, Multienergy CT, Hypoperfusion© RSNA, 2023.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Bird E, Hasenstab K, Kim N, et al. Mapping the Spatial Extent of Hypoperfusion in Chronic Thromboembolic Pulmonary Hypertension Using Multienergy CT. Radiol Cardiothorac Imaging. 2023. PMID: 37693197. doi:10.1148/ryct.220221

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。