文献速递胸部CT

利用CT影像特征预测非小细胞肺癌脏层胸膜侵犯

Using CT imaging features to predict visceral pleural invasion of non-small-cell lung cancer.
PubMed 文献 · Clin Radiol · 2023-08-23

回顾性纳入1573例肿瘤≤3 cm的非小细胞肺癌患者,比较基于CT影像特征的模型与联合临床数据的模型预测脏层胸膜侵犯的诊断效能。影像特征模型与联合模型诊断效能相当,训练组AUC分别为0.862与0.868(p=0.377),验证组AUC均为0.884。实性接触长度最佳截断值为7.5 mm(敏感度68.9%,特异度75.5%)。

要点

  • 胸膜标签数、实性接触长度和阻塞性炎症是脏层胸膜侵犯的独立影像预测因子。
  • 实性接触长度预测脏层胸膜侵犯的最佳截断值为7.5 mm,敏感度68.9%,特异度75.5%。
  • 影像特征模型与联合临床数据模型诊断效能相当,训练组AUC 0.862 vs 0.868(p=0.377)。

核心结论

  • 基于CT影像特征的模型在预测胸膜侵犯方面显示出较大潜力,与含临床数据的联合模型诊断效能相当。

研究设计与样本

  • 回顾性纳入1573例肿瘤大小≤3 cm的非小细胞肺癌患者,分析临床、病理及术前影像特征与脏层胸膜侵犯的关系,采用多因素logistic回归建立预测模型。

关键影像表现/征象

  • 胸膜标签数、实性接触长度和阻塞性炎症为影像独立预测因子(p均<0.001)。
  • 手术史(p=0.014)和肿瘤标志物(p=0.003)亦为独立风险预测因子。

诊断标准与关键数值

  • 训练组:联合模型敏感度88.9%、特异度73.5%、AUC 0.868(95% CI: 0.848-0.886);影像特征模型敏感度77%、特异度84.1%、AUC 0.862(95% CI: 0.842-0.880),两模型AUC比较p=0.377。
  • 验证组:联合模型敏感度93.5%、特异度74.3%;影像特征模型敏感度77.4%、特异度81.3%;两模型AUC均为0.884(95% CI: 0.842-0.919)。
  • 实性接触长度预测脏层胸膜侵犯的最佳截断值为7.5 mm,敏感度68.9%,特异度75.5%。

临床应用与阅片要点

  • 阅片时可关注胸膜标签数、实性接触长度及阻塞性炎症,用于辅助判断脏层胸膜侵犯。
  • 实性接触长度7.5 mm可作为预测脏层胸膜侵犯的参考截断值。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To examine the diagnostic performance of different models based on computed tomography (CT) imaging features in differentiating the invasiveness of non-small-cell lung cancer (NSCLC) with multiple pleural contact types.

MATERIALS AND METHODS: A total of 1,573 patients with NSCLC (tumour size ≤3 cm) were included retrospectively. The clinical and pathological data and preoperative imaging features of these patients were investigated and their relationships with visceral pleural invasion (VPI) were compared statistically. Multivariate logistic regression was used to eliminate confounding factors and establish different predictive models.

RESULTS: By univariate analysis and multivariable adjustment, surgical history, tumour marker (TM), number of pleural tags, length of solid contact and obstructive inflammation were identified as independent risk predictors of pleural invasiveness (p=0.014, 0.003, <0.001, <0.001, and 0.017, respectively). In the training group, comparison of the diagnostic efficacy between the combined model including these five independent predictors and the image feature model involving the latter three imaging predictors were as follows: sensitivity of 88.9% versus 77% and specificity of 73.5% versus 84.1%, with AUC of 0.868 (95% CI: 0.848-0.886) versus 0.862 (95% CI: 0.842-0.880; p=0.377). In the validation group, the sensitivity and specificity of these two models were as follow: the combined model, 93.5% and 74.3%, the imaging feature model, 77.4% and 81.3%, and their areas under the curve (AUCs) were both 0.884 (95% CI: 0.842-0.919). The best cut-off value of length of solid contact was 7.5 mm (sensitivity 68.9%, specificity 75.5%).

CONCLUSIONS: The image feature model showed great potential in predicting pleural invasiveness, and had comparable diagnostic efficacy compared with the combined model containing clinical data.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Yang Y, Xie Z, Hu H, et al. Using CT imaging features to predict visceral pleural invasion of non-small-cell lung cancer. Clin Radiol. 2023. PMID: 37666721. doi:10.1016/j.crad.2023.08.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。