文献速递神经外周血管CT

深度学习重建提升80kVp脑CT灌注数据衍生CT血管造影的图像质量

Deep Learning Reconstruction Improves the Image Quality of CT Angiography Derived From 80-kVp Cerebral CT Perfusion Data.
PubMed 文献 · Acad Radiol · 2023-09-26

研究前瞻性纳入33例接受80kVp脑CT灌注检查的患者,比较深度学习重建(DLR)与混合迭代重建(HIR)所生成CT血管造影的图像质量。结果显示DLR峰值图像在颈内动脉和基底动脉的CT值及对比噪声比最高,主观评分最优(4.93±0.4),且四种序列对血管狭窄程度的评估一致。

要点

  • DLR峰值图像在颈内动脉和基底动脉的CT值与对比噪声比最高(均p<0.001)。
  • DLR峰值图像主观评分4.93±0.4,显著优于其他三种HIR CTA图像(均p<0.001)。
  • 四种序列评估血管狭窄程度一致。

核心结论

  • 对于80kVp脑CT灌注数据衍生的CTA,深度学习重建图像质量及颅内动脉显示优于混合迭代重建及其他现行技术。

研究设计与样本

  • 前瞻性纳入33例接受80kVp脑CT灌注检查的患者,CTP数据分别用HIR和DLR重建,生成HIRpeak、DLRpeak、HIRtMIP和HIRtAve四组图像数据集,比较颈内动脉和基底动脉的CT值、标准差、信噪比和对比噪声比,并进行五分法主观评分和动脉狭窄评估。

关键影像表现/征象

  • DLR峰值图像在颈内动脉和基底动脉的CT值和对比噪声比最高(均p<0.001)。
  • DLR峰值图像主观图像质量最佳,评分4.93±0.4,高于其他三种HIR CTA图像(均p<0.001)。

诊断标准与关键数值

  • 主观图像质量采用五分法评分,DLR峰值图像评分4.93±0.4。
  • 血管狭窄程度在HIRtAve、HIRpeak、HIRtMIP和DLRpeak四种序列间评估一致。

临床应用与阅片要点

  • DLR峰值图像可能改善颅内动脉的可视化,但原文未据此给出具体推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVE: To investigate the impact of the deep learning reconstruction (DLR) technique on the image quality of CT angiography (CTA) derived from 80-kVp cerebral CT perfusion (CTP) data and compare it with hybrid-iterative reconstruction (HIR).

MATERIALS AND METHODS: Thirty-three patients underwent CTP at 80 kVp were prospectively enrolled. CTP data were reconstructed with HIR and DLR. Four image datasets were reconstructed: HIRpeak and DLRpeak were single arterial phase images derived from the time point showing the peak value, HIRtMIP and HIRtAve were time-resolved maximum intensity projection image and time-resolved average image derived from three time points with the greatest enhancement of HIR. The mean CT values, standard deviation, signal-to-noise ratio, and contrast-to-noise ratio of the internal carotid artery and basilar artery were compared among the four image dataset. Image quality was performed using a five-point rating scale. Arterial stenosis was evaluated.

RESULTS: DLRpeak had the highest CT value and contrast-to-noise ratio in the internal carotid artery and basilar artery (all p < 0.001). DLRpeak showed the best subjective image quality and had the highest score (4.93 ± 0.4) compared to the other three HIR CTA images (all p < 0.001). The degree of vascular stenosis was consistent among the four evaluated sequences (HIRtAve, HIRpeak, and HIRtMIP DLRpeak).

CONCLUSION: For CTA derived from 80-kVp cerebral CTP data, images reconstructed with deep learning showed better image quality and improved intracranial artery visualization than those processed with HIR and other currently used techniques.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Chen Y, Wang Y, Su T, et al. Deep Learning Reconstruction Improves the Image Quality of CT Angiography Derived From 80-kVp Cerebral CT Perfusion Data. Acad Radiol. 2023. PMID: 37758584. doi:10.1016/j.acra.2023.02.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。