文献速递神经MR

基于k空间数据的超分辨率深度学习重建在脑扩散加权成像中的可行性研究

Feasibility study of super-resolution deep learning-based reconstruction using k-space data in brain diffusion-weighted images.
PubMed 文献 · Neuroradiology · 2023-09-07

本研究回顾性分析34例在3 T MRI上接受脑DWI检查的患者,比较使用与不使用基于k空间数据的超分辨率深度学习重建(SR-DLR)的图像质量与ADC定量。SR-DLR组图像信噪比和对比噪声比显著更高(p < 0.001),白质和灰质ADC值无显著差异(p = 0.945和p = 0.235),但SR-DLR组透明隔FWHM显著更高(p < 0.001)。结论认为SR-DLR有潜力提升DWI图像质量而不显著影响ADC定量。

要点

  • SR-DLR可显著提高脑DWI的信噪比和对比噪声比(p < 0.001)。
  • SR-DLR对白质和灰质ADC定量无显著影响(p = 0.945和p = 0.235)。
  • SR-DLR组透明隔FWHM显著高于非SR-DLR组(p < 0.001)。

核心结论

  • SR-DLR有潜力在不显著影响ADC定量的情况下提升脑MRI扩散加权图像的质量。

研究设计与样本

  • 回顾性分析,纳入34例于2022年8月使用3 T MRI系统接受脑DWI检查的患者,图像分别采用SR-DLR(矩阵684×684)和不采用SR-DLR(矩阵228×228)重建。

诊断标准与关键数值

  • SR-DLR组图像信噪比和对比噪声比显著高于非SR-DLR组(p < 0.001)。
  • 白质ADC值在SR-DLR组与非SR-DLR组间无显著差异(p = 0.945);灰质ADC值在两组间无显著差异(p = 0.235)。
  • 透明隔FWHM在非SR-DLR组显著低于SR-DLR组(p < 0.001)。
  • 两名放射科医师采用四点量表评估图像噪声、对比度、伪影、模糊度和整体质量。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The purpose of this study is to evaluate the influence of super-resolution deep learning-based reconstruction (SR-DLR), which utilizes k-space data, on the quality of images and the quantitation of the apparent diffusion coefficient (ADC) for diffusion-weighted images (DWI) in brain magnetic resonance imaging (MRI).

METHODS: A retrospective analysis was performed on 34 patients who had undergone DWI using a 3 T MRI system with SR-DLR reconstruction based on k-space data in August 2022. DWI was reconstructed with SR-DLR (Matrix = 684 × 684) and without SR-DLR (Matrix = 228 × 228). Measurements were made of the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) in white matter (WM) and grey matter (GM), and the full width at half maximum (FWHM) of the septum pellucidum. Two radiologists assessed image noise, contrast, artifacts, blur, and the overall quality of three image types using a four-point scale. Quantitative and qualitative scores between images with and without SR-DLR were compared using the Wilcoxon signed-rank test.

RESULTS: Images with SR-DLR showed significantly higher SNRs and CNRs than those without SR-DLR (p < 0.001). No statistically significant variances were found in the apparent diffusion coefficients (ADCs) in WM and GM between images with and without SR-DLR (ADC in WM, p = 0.945; ADC in GM, p = 0.235). Moreover, the FWHM without SR-DLR was notably lower compared to that with SR-DLR (p < 0.001).

CONCLUSION: SR-DLR has the potential to augment the quality of DWI in DL MRI scans without significantly impacting ADC quantitation.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Matsuo K, Nakaura T, Morita K, et al. Feasibility study of super-resolution deep learning-based reconstruction using k-space data in brain diffusion-weighted images. Neuroradiology. 2023. PMID: 37673835. doi:10.1007/s00234-023-03212-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。