短胼胝体病例的胎儿MRI扩散张量成像定量研究
本研究回顾性纳入22例超声疑似孤立性短胼胝体胎儿与66例正常胼胝体胎儿,采用1.5T MRI扩散张量成像比较胼胝体各段FA与ADC值。45.5%短胼胝体病例可见Probst束,该组胼胝体各段FA值显著低于无Probst束组,ADC值在胼胝体整体、膝部及体部显著升高;无Probst束的孤立性短胼胝体与正常胼胝体相比FA和ADC无显著差异。
要点
- 短胼胝体伴Probst束者胼胝体各段FA值显著降低,ADC值在整体、膝部和体部显著升高。
- 无Probst束的孤立性短胼胝体FA与ADC值与正常胼胝体无显著差异,支持其为正常变异。
- 胎儿DTI有助于区分短胼胝体伴Probst束的白质微结构改变与不伴Probst束的正常变异。
核心结论
- 短胼胝体伴Probst束病例较正常胼胝体FA值显著降低、ADC值趋于显著升高,提示白质微结构改变;孤立性短胼胝体不伴Probst束DTI参数无显著改变,支持其为正常胼胝体变异。
研究设计与样本
- 回顾性研究,纳入2016年11月至2022年12月法国巴黎Necker医院因超声发现疑似孤立性短胼胝体转诊行MRI评估的病例22例,按胎儿性别和孕龄1:3匹配66例来自LUMIERE on the FETUS试验(NCT04142606)的正常胼胝体胎儿作为对照;使用1.5-Tesla Signa系统,采集胎儿脑T2加权轴位和矢状位序列测量胼胝体长度和厚度,以及16方向DTI轴位脑序列识别Probst束并生成胼胝体整体、膝部、体部和压部的FA和ADC值;排除MRI检出其他相关脑异常的病例。
关键影像表现/征象
- 短胼胝体病例胼胝体尺寸较正常胼胝体病例显著减小(均P < 0.01)。
- 22例短胼胝体中10例(45.5%)检出Probst束。
- 短胼胝体伴Probst束组胼胝体整体FA中位数0.21(范围0.19-0.24)低于不伴Probst束组0.24(范围0.22-0.28),P < 0.01。
- 短胼胝体伴Probst束组膝部FA中位数0.21(范围0.15-0.29)低于不伴Probst束组0.24(范围0.17-0.29),P = 0.04;体部FA中位数0.21(范围0.18-0.23)低于不伴Probst束组0.23(范围0.21-0.27),P = 0.04;压部FA中位数0.22(范围0.16-0.30)低于不伴Probst束组0.25(范围0.20-0.29),P = 0.03。
- 短胼胝体伴Probst束组胼胝体整体、膝部和体部ADC值显著高于不伴Probst束组(均P < 0.05);伴Probst束组所有FA值显著低于正常胼胝体组,胼胝体体部ADC值显著高于正常胼胝体组(均P < 0.05)。
诊断标准与关键数值
- 短胼胝体伴Probst束组胼胝体整体FA中位数0.21(范围0.19-0.24)vs 不伴Probst束组0.24(范围0.22-0.28),P < 0.01。
- 短胼胝体伴Probst束组膝部FA中位数0.21(范围0.15-0.29)vs 不伴Probst束组0.24(范围0.17-0.29),P = 0.04。
- 短胼胝体伴Probst束组体部FA中位数0.21(范围0.18-0.23)vs 不伴Probst束组0.23(范围0.21-0.27),P = 0.04。
- 短胼胝体伴Probst束组压部FA中位数0.22(范围0.16-0.30)vs 不伴Probst束组0.25(范围0.20-0.29),P = 0.03。
- 短胼胝体伴Probst束组胼胝体整体、膝部和体部ADC值显著高于不伴Probst束组(均P < 0.05);不伴Probst束组FA和ADC值与正常胼胝体组无显著差异(均P > 0.05)。
临床应用与阅片要点
- 胎儿胼胝体DTI定量参数(FA、ADC)可用于评估短胼胝体病例的白质微结构,并辅助识别Probst束。
- 短胼胝体不伴Probst束且DTI参数与正常胼胝体无显著差异时,支持其为正常胼胝体变异的可能性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: It has been suggested previously that the presence of Probst bundles (PB) in cases with a short corpus callosum (SCC) on diffusion tensor imaging (DTI) may help to differentiate between corpus callosal (CC) dysplasia and a variant of normal CC development. The objectives of this study were to compare DTI parameters between cases of SCC vs normal CC and between cases of SCC with PB (SCC-PB+) vs SCC without PB (SCC-PB-).
METHODS: This was a retrospective study of patients referred to the Necker Hospital in Paris, France, for magnetic resonance imaging (MRI) evaluation of an apparently isolated SCC detected by sonography between November 2016 and December 2022 (IRB: 00011928). MRI was performed using a 1.5-Tesla Signa system. T2-weighted axial and sagittal sequences of the fetal brain were used to measure the length and thickness of the CC. 16-direction DTI axial brain sequences were performed to identify the presence of PB and to generate quantitative imaging parameters (fractional anisotropy (FA) and apparent diffusion coefficient (ADC)) of the entire CC, genu, body and splenium. Cases in which other associated brain abnormalities were detected on MRI were excluded. Cases were matched for fetal gender and gestational age with controls in a 1:3 ratio. Control cases were normal fetuses included in the LUMIERE on the FETUS trial (NCT04142606) that underwent the same DTI evaluation of the brain. Comparisons between SCC and normal CC cases, and between SCC-PB+ and SCC-PB- cases were performed using ANOVA and adjusted for potential confounders using ANCOVA.
RESULTS: Twenty-two SCC cases were included and compared with 66 fetuses with a normal CC. In 10/22 (45.5%) cases of SCC, PB were identified. As expected, dimensions of the CC were significantly smaller in SCC compared with normal CC cases (all P < 0.01). In SCC-PB+ vs SCC-PB- cases, FA values were significantly lower in the entire CC (median, 0.21 (range, 0.19-0.24) vs 0.24 (range, 0.22-0.28); P < 0.01), genu (median, 0.21 (range, 0.15-0.29) vs 0.24 (range, 0.17-0.29); P = 0.04), body (median, 0.21 (range, 0.18-0.23) vs 0.23 (range, 0.21-0.27); P = 0.04) and splenium (median, 0.22 (range, 0.16-0.30) vs 0.25 (range, 0.20-0.29); P = 0.03). ADC values were significantly higher in the entire CC, genu and body in SCC-PB+ vs SCC-PB- cases (all P < 0.05). In SCC-PB+ cases, all FA values were significantly lower, and ADC values in the CC body were significantly higher compared with normal CC cases (all P < 0.05). In SCC-PB- cases, there was no significant difference in FA and ADC compared with normal CC cases (all P > 0.05).
CONCLUSIONS: Fetal DTI evaluation of the CC showed that FA values were significantly lower and ADC values tended to be significantly higher in SCC-PB+ compared with normal CC cases. This may highlight alterations of the white matter microstructure in SCC-PB+. In contrast, isolated SCC-PB- did not demonstrate significant changes in DTI parameters, strengthening the possibility that this is a normal CC variant. © 2023 International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Corroenne R, Grevent D, Mahallati H, et al. Quantitative fetal MRI with diffusion tensor imaging in cases with 'short' corpus callosum. Ultrasound Obstet Gynecol. 2024. PMID: 37676105. doi:10.1002/uog.27473
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。