自发性头颈动脉夹层的基线与随访高分辨率血管壁MRI研究
回顾性分析103例自发性头颈动脉夹层患者的基线及随访高分辨率血管壁MRI,发现假性动脉瘤与缺血性卒中风险降低相关,而管腔内血栓及Willis环不完整与卒中风险升高独立相关;双腔和闭塞与血管无重塑相关。
要点
- 管腔内血栓、Willis环不完整或部分完整与自发性头颈动脉夹层继发缺血性卒中独立相关。
- 假性动脉瘤的存在与缺血性卒中风险降低相关(OR 0.178)。
- 双腔和闭塞与随访血管无重塑相关,高分辨率血管壁MRI可用于评估夹层演变。
核心结论
- 多个基线因素与自发性头颈动脉夹层的卒中发生及解剖学结局相关,高分辨率血管壁MRI可能为夹层的病理生理和演变提供有价值的信息。
研究设计与样本
- 回顾性分析连续自发性头颈动脉夹层患者,共103例患者115条夹层动脉,其中46例患者(44.7%,51条血管)有随访高分辨率血管壁MRI,中位随访间隔8.5个月;采用二元logistic回归评估临床和影像因素及Willis环变异与缺血性卒中的关联,采用有序logistic回归评估基线特征与解剖学结局的关联。
关键影像表现/征象
- 假性动脉瘤与缺血性卒中风险降低相关(OR 0.178,95%CI 0.039-0.810,p=0.026)。
- 管腔内血栓与缺血性卒中风险升高独立相关(OR 5.558,95%CI 1.739-17.765,p=0.004)。
- Willis环不完整与缺血性卒中风险升高独立相关(OR 9.309,95%CI 2.122-40.840,p=0.003)。
- Willis环部分完整与缺血性卒中风险升高独立相关(OR 4.463,95%CI 1.211-16.453,p=0.025)。
- 双腔与无重塑相关(OR 5.749,95%CI 1.358-24.361,p=0.018),闭塞与无重塑相关(OR 12.975,95%CI 3.022-55.645,p=0.001)。
诊断标准与关键数值
- 解剖学结局根据血管壁和管腔变化分为完全重塑、部分重塑和无重塑。
临床应用与阅片要点
- 基线高分辨率血管壁MRI上识别管腔内血栓、Willis环不完整或部分完整可能提示继发缺血性卒中风险较高。
- 假性动脉瘤的存在似乎较少导致缺血性卒中。
- 随访高分辨率血管壁MRI可用于观察夹层的长期演变和解剖学结局,双腔和闭塞与无重塑相关。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To explore the factors associated with ischemic stroke secondary to spontaneous cervicocranial artery dissection (sCCAD) and evaluate the initial imaging markers related to outcomes.
METHODS: Initial and follow-up high-resolution vessel wall MRI (VW-MRI) in consecutive patients with sCCAD were retrospectively analyzed. The associations of clinical and imaging factors and variants of the circle of Willis (COW) with ischemic stroke were evaluated using binary logistic regression analyses. The anatomical outcomes were categorized as complete, partial, and no remodeling based on changes of the vessel wall and lumen. Ordinal logistic regression analysis was used to assess associations between initial features and outcomes.
RESULTS: A total of 115 dissected arteries (79 strokes, 36 non-strokes) were detected in 103 patients. Follow-up VW-MRI was available in 46 patients (44.7%, with 51 vessels), with a median interval of 8.5 months. Pseudoaneurysm (odd ratio [OR], 0.178; 95% confidence interval [CI], 0.039-0.810; p = 0.026) tended to rarely cause ischemic stroke, while intraluminal thrombus (OR, 5.558; 95% CI, 1.739-17.765; p = 0.004), incomplete COW (OR, 9.309; 95% CI, 2.122-40.840; p = 0.003), and partial complete COW (OR, 4.463; 95% CI, 1.211-16.453; p = 0.025) were independently associated with stroke occurrence. Furthermore, the presence of double lumen (OR, 5.749; 95% CI, 1.358-24.361; p = 0.018) and occlusion (OR, 12.975; 95% CI, 3.022-55.645; p = 0.001) were associated with no remodeling of sCCAD.
CONCLUSIONS: Multiple initial factors were found to be related to stroke occurrence and anatomical outcomes of sCCAD. High-resolution VW-MRI may provide valuable insights into the pathophysiology and evolution of sCCAD.
CLINICAL RELEVANCE STATEMENT: Initial and follow-up high-resolution vessel wall MRI may help elucidate the pathophysiology of spontaneous cervicocranial artery dissection and provide important insights into the evolution and further facilitate the optimal management of patients with spontaneous cervicocranial artery dissection.
KEY POINTS: • Clinical and imaging factors, as well as the status of primary collateral circulation, are associated with ischemic stroke secondary to spontaneous cervicocranial artery dissection. • The follow-up high-resolution vessel wall MRI provides valuable insights into the long-term evolution and anatomical outcomes of spontaneous cervicocranial artery dissection. • The high-resolution vessel wall MRI features related to ischemic stroke and anatomical outcomes may further facilitate the optimal management of patients with spontaneous cervicocranial artery dissection.
引用
- Lin X, Guo W, She D, et al. Initial and follow-up high-resolution vessel wall MRI study of spontaneous cervicocranial artery dissection. Eur Radiol. 2023. PMID: 37670185. doi:10.1007/s00330-023-10207-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。