左心耳封堵器CT检出低密度增厚的临床意义
这项前瞻性研究纳入412例接受左心耳封堵术的高卒中风险房颤患者,术后平均4.2个月行CT随访,由两名放射科医师共识判读并按器械专属算法将封堵器心房面低密度增厚分为低级别和高级别。低级别增厚见于23.8%患者、高级别见于5.1%,高级别增厚与随访期抗栓药停用风险升高及卒中风险升高相关,低级别增厚与左心耳持续通畅风险降低相关。
要点
- 左心耳封堵术后CT随访中,封堵器心房面低密度增厚需按器械专属算法分级判读。
- 低级别增厚占23.8%,高级别增厚占5.1%,前者与左心耳持续通畅风险降低相关。
- 高级别增厚与随访期抗栓药停用及卒中风险升高相关,低级别增厚与卒中无关。
核心结论
- 低级别增厚(23.8%)较低级别更常见,且较低级别预后更有利;高级别增厚与随访期抗栓药停用风险升高及卒中风险升高相关。
研究设计与样本
- 前瞻性研究,纳入2012年1月至2020年11月法国两家医疗中心412例接受左心耳封堵术的房颤高卒中风险患者(CHA2DS2-VASc评分≥4),使用塞子型或非塞子型封堵器,术后平均4.2个月±1.7行CT随访,由两名放射科医师共识判读并应用器械专属判读算法。
关键影像表现/征象
- 封堵器心房面低密度增厚表现为低级别(血栓低怀疑)或高级别(血栓高怀疑),需按器械专属算法分级。
诊断标准与关键数值
- 低级别增厚定义为血栓低怀疑,见于98/412例(23.8%)。
- 高级别增厚定义为血栓高怀疑,见于21/412例(5.1%)。
临床应用与阅片要点
- 术后CT判读封堵器心房面低密度增厚时,应按所用封堵器的专属判读算法区分低级别与高级别。
- 高级别增厚与随访期抗栓药停用风险升高相关(比值比9.5;95%CI:3.1,29.1;P<.001)。
- 高级别增厚与卒中相关(风险比4.6;95%CI:1.5,14.0;P=.008),低级别增厚与卒中无关(P=.62)。
- 低级别增厚与左心耳持续通畅风险降低相关(比值比0.46;95%CI:0.27,0.79;P=.005)。
局限性
- 原文指出封堵器心房面低密度增厚的临床意义需进一步研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background At follow-up CT after left atrial appendage occlusion (LAAO), hypoattenuation thickening (HAT) on the atrial aspect of the device is a common finding but the clinical implications require further study. Purpose To assess the association of HAT grade at follow-up CT with clinical characteristics and outcomes in patients who underwent LAAO. Materials and Methods This prospective study included consecutive participants with atrial fibrillation and who were at high risk for stroke (CHA2DS2-VASc score ≥4) who underwent LAAO and were administered pacifier or nonpacifier devices at two French medical centers between January 2012 and November 2020. Postprocedure CT images were evaluated by two radiologists in consensus and device-specific interpretation algorithms were applied to classify HAT as low grade (low suspicion of thrombosis) or high grade (high suspicion of thrombosis). The association between HAT grade and clinical characteristics was assessed using multinomial logistic regression, and variables associated with risk of stroke were assessed using a Cox proportional hazard model. Results This study included 412 participants (mean age, 76 years ± 8 [SD]; 284 male participants) who underwent follow-up CT at a mean of 4.2 months ± 1.7 after LAAO. Low-grade and high-grade HAT were depicted in 98 of 412 (23.8%) and 21 of 412 (5.1%) participants, respectively. High-grade HAT was associated with higher odds of antithrombotic drug discontinuation during follow-up (odds ratio, 9.5; 95% CI: 3.1, 29.1; P < .001), whereas low-grade HAT was associated with lower odds of persisting left atrial appendage patency (odds ratio, 0.46; 95% CI: 0.27, 0.79; P = .005). During a median follow-up of 17 months (IQR, 11-41 months), stroke occurred in 24 of 412 (5.8%) participants. High-grade HAT was associated with stroke (hazard ratio, 4.6; 95% CI: 1.5, 14.0; P = .008) and low-grade HAT (P = .62) was not. Conclusion Low-grade HAT was a more common finding at CT performed after LAAO CT (24%) than was high-grade HAT (5%), but it was associated with more favorable outcomes than high-grade HAT, which was associated with higher stroke risk. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Choe in this issue.
引用
- Iriart X, Blanc G, Bouteiller XP, et al. Clinical Implications of CT-detected Hypoattenuation Thickening on Left Atrial Appendage Occlusion Devices. Radiology. 2023. PMID: 37668517. doi:10.1148/radiol.230462
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。