文献速递神经MR

弥散峰度成像的影像组学分析:区分胶质母细胞瘤与单发脑转移瘤

Radiomics Analysis of Diffusion Kurtosis Imaging: Distinguishing Between Glioblastoma and Single Brain Metastasis.
PubMed 文献 · Acad Radiol · 2023-09-09

本研究纳入110例经病理诊断的胶质母细胞瘤(58例)或单发脑转移瘤(52例)患者,基于弥散峰度成像(DKI)提取影像组学特征构建模型,并与常规MRI模型比较区分两种肿瘤的诊断性能。多参数DKI模型的AUC为0.958,显著高于多序列常规MRI模型的AUC(范围0.633~0.733,P=0.042),但与平均峰度(MK)单参数模型(AUC 0.933)的差异无统计学意义(P=0.688)。

要点

  • 多参数DKI影像组学模型区分胶质母细胞瘤与单发脑转移瘤的AUC为0.958,高于常规MRI模型。
  • 单参数DKI模型中MK模型AUC最高(0.933),多参数DKI模型较MK模型AUC略高但差异无统计学意义(P=0.688)。
  • 多参数DKI模型AUC显著高于多序列常规MRI模型(P=0.042)。

核心结论

  • 多参数DKI影像组学模型在区分胶质母细胞瘤与单发脑转移瘤方面表现出优于单参数DKI模型和常规MRI模型的性能。

研究设计与样本

  • 研究纳入110例接受DKI检查且经病理诊断的患者(胶质母细胞瘤58例,单发脑转移瘤52例),随机选取88例构建训练集用于模型开发,22例作为独立验证集;基于手动勾画的病灶感兴趣区提取影像组学特征,使用六种分类器构建7个单参数DKI模型和1个多参数DKI模型,并构建4个单序列常规MRI模型(基于T2加权成像、表观扩散系数、T2暗液、对比增强T1磁化准备快速梯度回波)和1个多序列常规MRI模型作为对照;采用受试者工作特征曲线分析评估诊断性能,DeLong检验比较不同模型的AUC。

诊断标准与关键数值

  • 单参数DKI模型的AUC范围为0.800至0.933(平均峰度模型);多参数DKI模型的AUC为0.958;常规MRI模型的AUC范围为0.633至0.733(多序列常规MRI模型);多参数DKI模型与MK模型的AUC差异无统计学意义(P=0.688);多参数DKI模型AUC显著高于多序列常规MRI模型(P=0.042)。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: This study aimed to assess the value of diffusion kurtosis imaging (DKI)-based radiomics models in differentiating glioblastoma (GB) from single brain metastasis (SBM) and compare their diagnostic performance with that of routine magnetic resonance imaging (MRI) models.

MATERIALS AND METHODS: A total of 110 patients who underwent DKI and were pathologically diagnosed with GB (n = 58) or SBM (n = 52) were enrolled in this study. Radiomics features were extracted from the manually delineated region of interest of the lesion. A training set for model development was constructed from the images of 88 random patients, and 22 patients were reserved for independent validation. Seven single-DKI-parametric models and a multi-DKI-parametric model were constructed using six classifiers, whereas four single-routine-sequence models (based on T2 weighted imaging, apparent diffusion coefficient, T2-dark-fluid, and contrast-enhanced T1 magnetization prepared rapid gradient echo) and a multisequence routine MRI model were constructed for comparison. Receiver operating characteristic curve analysis was conducted to assess the diagnostic performance. The areas under the curve (AUCs) of different models were compared using the DeLong test.

RESULTS: The AUCs of the single-DKI-parametric models ranged from 0.800 to 0.933 (mean kurtosis [MK] model). The multi-DKI-parametric model had a slightly higher AUC (0.958) than the MK model; however, the difference was not statistically significant (P = 0.688). In comparison, the AUCs of the routine MRI models ranged from 0.633 to 0.733 (multisequence routine MRI model). The AUC of the multi-DKI-parametric model was significantly higher than that of the multisequence routine MRI model (P = 0.042).

CONCLUSION: The multi-DKI-parametric radiomics model exhibited better performance than that of the single-DKI-parametric models and routine MRI models in distinguishing GB from SBM.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Gao E, Wang P, Bai J, et al. Radiomics Analysis of Diffusion Kurtosis Imaging: Distinguishing Between Glioblastoma and Single Brain Metastasis. Acad Radiol. 2023. PMID: 37690885. doi:10.1016/j.acra.2023.07.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。