指南与共识泌尿生殖介入PETCT

基于前列腺特异性膜抗原PET/CT的前列腺切除术后挽救性放疗临床靶区勾画指南:PERYTON指南

Prostate-Specific Membrane Antigen Positron Emission Tomography/Computed Tomography-Based Clinical Target Volume Delineation Guideline for Postprostatectomy Salvage Radiation Therapy: The PERYTON Guideline.
指南 / 共识 · Int J Radiat Oncol Biol Phys · 2023-09-18

本研究在9家荷兰中心回顾性纳入前列腺切除术后PSMA PET/CT疑似局部复发患者,由专家核医学医师中心判读,逐边界评估并调整GFRU临床靶区(CTV)指南以提高对PSMA PET/CT检出局部复发的覆盖率。最终提出PERYTON-CTV,将局部复发覆盖率从67%提高至96%,同时较GFRU-CTV缩小25%,平均Dice相似系数0.82(范围0.81-0.83)。

要点

  • PERYTON-CTV较GFRU-CTV对PSMA PET/CT检出局部复发的覆盖率为96% vs 67%,同时体积缩小25%。
  • PERYTON-CTV在参与中心间可重复性高,平均Dice相似系数0.82(范围0.81-0.83)。
  • 该指南基于PSMA PET/CT检出的局部复发模式优化前列腺切除术后挽救性放疗CTV勾画。

核心结论

  • 利用PSMA PET/CT检出的局部复发模式优化前列腺切除术后挽救性外照射放疗的CTV定义,PERYTON-CTV在参与中心间高度可重复,确保覆盖96%的局部复发,同时较GFRU-CTV缩小25%。

研究设计与样本

  • 回顾性研究,在9家荷兰中心纳入前列腺切除术后PSMA PET/CT疑似局部复发的患者,匿名扫描由专家核医学医师中心判读,逐边界评估并调整GFRU的CTV指南,与参与中心放射肿瘤科医师讨论达成最终共识,并要求参与中心按新PERYTON-CTV勾画3例新病例以Dice相似系数评估可重复性。

诊断标准与关键数值

  • 中心判读后,在83例PSMA PET/CT上识别出93处局部复发;与GFRU-CTV相比,所提出的CTV定义将PSMA PET/CT检出局部复发的覆盖率从67%提高至96%,同时使GFRU-CTV缩小25%;新CTV可重复性高,平均Dice相似系数0.82(范围0.81-0.83)。

临床应用与阅片要点

  • 作者提出PERYTON-CTV用于前列腺切除术后挽救性外照射放疗的临床靶区勾画,该靶区在参与中心间高度可重复,覆盖96%的PSMA PET/CT检出局部复发,并较GFRU-CTV缩小25%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Prostate-specific membrane antigen positron emission tomography/computed tomography (PSMA PET/CT) scan is the standard imaging procedure for biochemical recurrent prostate cancer postprostatectomy because of its high detection rate at low serum prostate-specific antigen levels. However, existing guidelines for clinical target volume (CTV) in prostate bed salvage external beam radiation therapy (sEBRT) are primarily based on experience-based clinical consensus and have been validated using conventional imaging modalities. Therefore, this study aimed to optimize CTV definition in sEBRT by using PSMA PET/CT-detected local recurrences (LRs).

METHODS AND MATERIALS: Patients with suspected LR on PSMA PET/CT postprostatectomy were retrospectively enrolled in 9 Dutch centers. Anonymized scans were centrally reviewed by an expert nuclear medicine physician. Each boundary of the CTV guideline from the Groupe Francophone de Radiothérapie en Urologie (GFRU) was evaluated and adapted to improve the accuracy and coverage of the area at risk of LR (CTV) on PSMA PET/CT. The proposed CTV adaptation was discussed with the radiation oncologists of the participating centers, and final consensus was reached. To assess reproducibility, the participating centers were asked to delineate 3 new cases according to the new PERYTON-CTV, and the submitted contours were evaluated using the Dice similarity coefficient (DSC).

RESULTS: After central review, 93 LRs were identified on 83 PSMA PET/CTs. The proposed CTV definition improved the coverage of PSMA PET/CT-detected LRs from 67% to 96% compared with the GFRU-CTV, while reducing the GFRU-CTV by 25%. The new CTV was highly reproducible, with a mean DSC of 0.82 (range, 0.81-0.83).

CONCLUSIONS: This study contributes to the optimization of CTV definition in postprostatectomy sEBRT by using the pattern of LR detected on PSMA PET/CT. The PERYTON-CTV is highly reproducible across the participating centers and ensures coverage of 96% LRs while reducing the GFRU-CTV by 25%.

来源:Int J Radiat Oncol Biol Phys,查看原文。版权归原作者所有。

引用

  1. Staal FHE, Janssen J, Oprea-Lager DE, et al. Prostate-Specific Membrane Antigen Positron Emission Tomography/Computed Tomography-Based Clinical Target Volume Delineation Guideline for Postprostatectomy Salvage Radiation Therapy: The PERYTON Guideline. Int J Radiat Oncol Biol Phys. 2023. PMID: 37729971. doi:10.1016/j.ijrobp.2023.09.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。