用于单角度平面波成像的复数变换器网络

Complex Transformer Network for Single-Angle Plane-Wave Imaging.
PubMed 文献 · Ultrasound Med Biol · 2023-08-04

研究提出一种整合复数卷积与复数自注意力模块的复数变换器网络(CTN),以0°单角度平面波复数IQ数据为输入、最小方差(MV)为训练标签,在仿真、体模与在体实验中图像质量与MV相当或更高且计算时间大幅缩短,GPU加速后CTN运行时间76.03 ms与DAS的61.24 ms相当。

要点

  • CTN以MV为训练标签,在仿真、体模与在体实验中图像质量与MV相当或更高,但计算时间大幅缩短。
  • 仿真评估指标为对比度-11.59 dB、对比噪声比1.16、广义对比噪声比0.68、横向与轴向半高全宽278 μm与329 μm。
  • 体模实验对应指标为9.87 dB、0.96、0.62、357 μm与305 μm;在体实验显示CTN可显著改善DAS与MV图像中模糊甚至不可见的细节。

核心结论

  • 所提出的CTN通过MV波束形成器显著改善了图像对比度、分辨率及一些不清晰细节,使其成为高帧率成像的有效工具。

研究设计与样本

  • 研究提出复数变换器网络(CTN),输入为0°单角度平面波的复数IQ数据,训练标签由最小方差(MV)生成,在仿真、体模与在体实验中评估。

诊断标准与关键数值

  • 仿真评估指标:对比度-11.59 dB、对比噪声比1.16、广义对比噪声比0.68、横向半高全宽278 μm、轴向半高全宽329 μm。
  • 体模实验评估指标:对比度9.87 dB、对比噪声比0.96、广义对比噪声比0.62、横向半高全宽357 μm、轴向半高全宽305 μm。
  • CTN在仿真、体模与在体实验中产生与MV相当甚至更高质量的图像,但计算时间大幅缩短。
  • GPU加速后CTN运行时间76.03 ms,与延迟叠加(DAS)的61.24 ms相当。
  • 在体实验显示CTN可显著改善DAS与MV图像中先前模糊甚至不可见的细节。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Plane-wave imaging (PWI) is a high-frame-rate imaging technique that sacrifices image quality. Deep learning can potentially enhance plane-wave image quality, but processing complex in-phase and quadrature (IQ) data and suppressing incoherent signals pose challenges. To address these challenges, we present a complex transformer network (CTN) that integrates complex convolution and complex self-attention (CSA) modules.

METHODS: The CTN operates in a four-step process: delaying complex IQ data from a 0° single-angle plane wave for each pixel as CTN input data; extracting reconstruction features with a complex convolution layer; suppressing irrelevant features derived from incoherent signals with two CSA modules; and forming output images with another complex convolution layer. The training labels are generated by minimum variance (MV).

RESULTS: Simulation, phantom and in vivo experiments revealed that CTN produced comparable- or even higher-quality images than MV, but with much shorter computation time. Evaluation metrics included contrast ratio, contrast-to-noise ratio, generalized contrast-to-noise ratio and lateral and axial full width at half-maximum and were -11.59 dB, 1.16, 0.68, 278 μm and 329 μm for simulation, respectively, and 9.87 dB, 0.96, 0.62, 357 μm and 305 μm for the phantom experiment, respectively. In vivo experiments further indicated that CTN could significantly improve details that were previously vague or even invisible in DAS and MV images. And after being accelerated by GPU, the CTN runtime (76.03 ms) was comparable to that of delay-and-sum (DAS, 61.24 ms).

CONCLUSION: The proposed CTN significantly improved the image contrast, resolution and some unclear details by the MV beamformer, making it an efficient tool for high-frame-rate imaging.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。