文献速递外周血管神经CT

基于CT的影像组学列线图识别易损颈动脉斑块

Identification of vulnerable carotid plaque with CT-based radiomics nomogram.
PubMed 文献 · Clin Radiol · 2023-08-14

本研究基于CTA影像提取影像组学特征,构建并验证了用于识别高危颈动脉斑块的影像组学列线图。在验证集中,列线图AUC为0.977,优于临床因素模型(AUC 0.862)和影像组学特征(AUC 0.944);在外部测试集中,列线图AUC为0.952,同样优于临床因素模型(AUC 0.818)。结论认为该列线图可能作为无创工具用于识别颈动脉斑块易损性和风险分层。

要点

  • 列线图在验证集识别高危颈动脉斑块的AUC为0.977(95%CI 0.899-0.999)。
  • 列线图在外部测试集AUC为0.952(95%CI 0.884-0.987),优于临床因素模型。
  • 钙化和最大斑块厚度是独立的临床因素。

核心结论

  • 基于CT的列线图在识别颈动脉高危斑块方面表现出满意性能,可能作为无创工具用于识别颈动脉斑块易损性和风险分层。

研究设计与样本

  • 研究纳入280例有症状(n=131)和无症状(n=139)颈动脉斑块患者,分为训练集(n=135)、验证集(n=58)和外部测试集(n=87);从CTA图像提取影像组学特征,构建影像组学模型并计算影像组学评分,构建临床因素模型,并联合独立临床因素与影像组学评分构建列线图,通过ROC曲线评估并验证三种模型的诊断性能。

诊断标准与关键数值

  • 验证集中列线图AUC为0.977(95%CI 0.899-0.999),优于临床因素模型(AUC 0.862,95%CI 0.746-0.938,p=0.017)和影像组学特征(AUC 0.944,95%CI 0.850-0.987,p=0.031)。外部测试集中列线图AUC为0.952(95%CI 0.884-0.987),影像组学特征AUC为0.932(95%CI 0.857-0.975),两者均优于临床因素模型(AUC 0.818,95%CI 0.721-0.892,p=0.002和p=0.037)。

临床应用与阅片要点

  • 作者认为该CT列线图可能作为无创工具用于识别颈动脉斑块易损性和进行风险分层。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To develop and validate a radiomics nomogram for identifying high-risk carotid plaques on computed tomography (CT) angiography (CTA).

MATERIALS AND METHODS: A total of 280 patients with symptomatic (n=131) and asymptomatic (n=139) carotid plaques were divided into a training set (n=135), validation set (n=58), and external test set (n=87). Radiomic features were extracted from CTA images. A radiomics model was constructed based on selected features and a radiomics score (rad-score) was calculated. A clinical factor model was constructed by demographics and CT findings. A radiomics nomogram combining independent clinical factors and the rad-score was constructed. The diagnostic performance of three models was evaluated and validated by region of characteristic curves.

RESULTS: Calcification and maximum plaque thickness were the independent clinical factors. Twenty-four features were used to build the radiomics signature. In the validation set, the nomogram (area under the curve [AUC], 0.977; 95% CI, 0.899-0.999) performed better (p=0.017 and p=0.031) than the clinical factor model (AUC, 0.862; 95% CI, 0.746-0.938) and radiomics signature (AUC, 0.944; 95% CI, 0.850-0.987). In external test set, the nomogram (AUC, 0.952; 95% CI, 0.884-0.987) and radiomics signature (AUC, 0.932; 95% CI, 0.857-0.975) showed better discrimination capability (p=0.002 and p=0.037) than clinical factor model (AUC, 0.818; 95% CI, 0.721-0.892).

CONCLUSION: The CT-based nomogram showed satisfactory performance in identification of high-risk plaques in carotid arteries, and it may serve as a potential non-invasive tool to identify carotid plaque vulnerability and risk stratification.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Liu M, Chang N, Zhang S, et al. Identification of vulnerable carotid plaque with CT-based radiomics nomogram. Clin Radiol. 2023. PMID: 37633746. doi:10.1016/j.crad.2023.07.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。