文献速递骨肌MR

磁共振指纹多组分成像定量膝关节软骨滑液研究

Quantification of Synovial Fluid Using Magnetic Resonance Fingerprinting Multicomponent Imaging in the Articular Cartilage of the Knee.
PubMed 文献 · Acad Radiol · 2023-08-16

本研究在3T扫描仪上验证磁共振指纹衍生滑液分数(SFF)图定量亚体素软骨缺损的可行性,离体牛骨钻孔实验显示SFF值随孔数增加而升高;16例骨关节炎患者中,SFF图与T2图的WORMS评分kappa系数分别为0.80和0.64,内侧胫股关节中SFF图与3D FSE参考的软骨体积相关系数优于T2图。

要点

  • 离体实验中SFF值随钻孔数增加而升高,提示可定量亚体素软骨缺损。
  • 临床16例骨关节炎患者中SFF图WORMS评分kappa系数0.80,T2图0.64。
  • 内侧胫股关节V3D-VSFF与V3D-VT2相关系数差异≥0.03,SFF图相关更优。

核心结论

  • MRF衍生SFF图可可行地评估小的不可见软骨缺损并定量软骨体积。

研究设计与样本

  • 离体实验使用牛骨钻孔(孔数4、6、8、10、12)比较SFF值;临床研究纳入16例骨关节炎患者,行矢状面3D快速自旋回波(FSE)和MRF扫描,以3D FSE图像上实际软骨体积(V3D)为参考,比较SFF图与T2图。

诊断标准与关键数值

  • SFF值随钻孔数增加而升高(孔数4、6、8、10、12)。
  • SFF图WORMS评分kappa系数0.80,T2图0.64,内侧胫股关节呈中度至几乎完全一致。
  • 内侧胫股关节V3D-VSFF与V3D-VT2相关系数差异≥0.03。

临床应用与阅片要点

  • MRF衍生SFF图可用于评估小的、不可见软骨缺损并定量软骨体积。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: The purpose of this study was to verify the feasibility of magnetic resonance fingerprinting (MRF)-derived synovial fluid fraction (SFF) mapping for quantifying subvoxel-sized cartilage defects.

MATERIALS AND METHODS: MRF was performed on a 3-Tesla scanner and used to derive T2 and SFF maps. An ex vivo experiment was performed using bovine bone; different numbers of holes (4, 6, 8, 10, and 12) were drilled separately on the articular surface, and SFF values were compared among the drilled areas. In a clinical study, 16 osteoarthritis patients underwent sagittal 3D fast spinecho (FSE) and MRF scanning, and knee cartilage segmentation was performed on each image. For morphologic analysis, fluid-excluded images of the SFF (FEISFF) and T2 maps (FEIT2) were generated using the cartilage segmentations, and the whole-organ magnetic resonance imaging score (WORMS) of each FEI and 3D FSE image were compared using the kappa coefficient. For quantitative analysis, intact cartilage volumes in the SFF (VSFF) and T2 maps (VT2) were calculated, and their correlations with reference to the actual cartilage volume on 3D FSE images (V3D) were evaluated.

RESULTS: In the ex vivo experiment, the SFF value increased as the number of holes increased. The kappa coefficients of the WORMS were 0.80 and 0.64 in the SFF and T2 maps, respectively, and substantial to almost perfect agreement was observed in the medial tibiofemoral joint. The V3D-VSFF and V3D-VT2 correlation coefficients differed by 0.03 or more in the medial tibiofemoral joint.

CONCLUSION: The MRF-derived SFF map can feasibly evaluate small, invisible cartilage defects and quantify cartilage volumes.

来源:Acad Radiol,查看原文。版权归原作者所有。