文献速递乳腺MR

体素内不相干运动(IVIM)与动态对比增强(DCE)MRI鉴别乳腺良恶性病变的诊断准确性:系统综述与Meta分析

Diagnostic accuracy of intravoxel incoherent motion (IVIM) and dynamic contrast-enhanced (DCE) MRI to differentiate benign from malignant breast lesions: A systematic review and meta-analysis.
PubMed 文献 · Eur J Radiol · 2023-08-16

本Meta分析纳入10项研究共537例患者、707个乳腺病变(435恶性、272良性),评估IVIM与DCE MRI鉴别乳腺良恶性病变的诊断准确性。D、f、Ktrans、Kep均值在良恶性病变间差异显著;IVIM汇总敏感度86.2%、特异度70.3%,DCE为93.8%、68.1%,两者联合AUC最高达0.94(敏感度91.8%、特异度87.6%)。联合IVIM与DCE诊断准确性最高,多参数MRI可能有助于减少不必要的良性乳腺活检。

要点

  • IVIM定量参数D、f、Ktrans、Kep均值在乳腺良恶性病变间差异显著。
  • IVIM汇总敏感度86.2%、特异度70.3%;DCE汇总敏感度93.8%、特异度68.1%。
  • IVIM联合DCE的AUC为0.94,敏感度91.8%、特异度87.6%。

核心结论

  • 联合IVIM与DCE诊断准确性最高(AUC 0.94),多参数MRI可能有助于减少不必要的良性乳腺活检。

研究设计与样本

  • 系统综述与Meta分析,系统检索PubMed、EMBASE和Scopus,纳入10项报告IVIM与DCE鉴别乳腺良恶性病变诊断准确性的英文研究,共537例患者、707个病变(435恶性、272良性),采用QUADAS-2评估质量,双变量效应模型行SMD分析与诊断试验准确性分析。

诊断标准与关键数值

  • IVIM汇总敏感度86.2%(95%CI 77.9%-91.7%)、特异度70.3%(95%CI 56.5%-81.1%);DCE汇总敏感度93.8%(95%CI 85.3%-97.5%)、特异度68.1%(95%CI 52.7%-80.4%);IVIM联合DCE的AUC为0.94,敏感度91.8%(95%CI 82.8%-96.3%)、特异度87.6%(95%CI 73.8%-94.7%)。

临床应用与阅片要点

  • 作者认为联合IVIM与DCE的多参数MRI可能有助于减少不必要的良性乳腺活检。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Magnetic resonance imaging (MRI) can reduce the need for unnecessary invasive diagnostic tests by nearly half. In this meta-analysis, we investigated the diagnostic accuracy of intravoxel incoherent motion modeling (IVIM) and dynamic contrast-enhanced (DCE) MRI in differentiating benign from malignant breast lesions.

METHOD: We systematically searched PubMed, EMBASE, and Scopus. We included English articles reporting diagnostic accuracy for both sequences in differentiating benign from malignant breast lesions. Articles were assessed by quality assessment of diagnostic accuracy studies-2 (QUADAS-2) questionnaire. We used a bivariate effects model for standardized mean difference (SMD) analysis and diagnostic test accuracy analysis.

RESULTS: Ten studies with 537 patients and 707 (435 malignant and 272 benign) lesions were included. The D, f, Ktrans, and Kep mean values significantly differ between benign and malignant lesions. The pooled sensitivity (95 % confidence interval) and specificity were 86.2 % (77.9 %-91.7 %) and 70.3 % (56.5 %-81.1 %) for IVIM, and 93.8 % (85.3 %-97.5 %) and 68.1 % (52.7 %-80.4 %) for DCE, respectively. Combined IVIM and DCE depicted the highest area under the curve of 0.94, with a sensitivity and specificity of 91.8 % (82.8 %-96.3 %) and 87.6 % (73.8 %-94.7 %), respectively.

CONCLUSIONS: Combined IVIM and DCE had the highest diagnostic accuracy, and multiparametric MRI may help reduce unnecessary benign breast biopsy.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Arian A, Seyed-Kolbadi FZ, Yaghoobpoor S, et al. Diagnostic accuracy of intravoxel incoherent motion (IVIM) and dynamic contrast-enhanced (DCE) MRI to differentiate benign from malignant breast lesions: A systematic review and meta-analysis. Eur J Radiol. 2023. PMID: 37632999. doi:10.1016/j.ejrad.2023.111051

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。