基线动态增强MRI定量评估乳腺实质特征与极高密度乳腺女性乳腺癌发生的关系
本研究为Dense Tissue and Early Breast Neoplasm Screening试验的二次分析,纳入4553例极高密度乳腺女性,从基线DCE MRI提取乳腺实质定量特征,评估其与乳腺癌发生的关联。结果显示强化实质体积与乳腺癌发生相关(HR 1.09,95%CI 1.01-1.18,P=0.02),高三分位组乳腺癌发生率为低三分位组的2倍(HR 2.09,95%CI 1.25-3.61,P=0.005)。
要点
- 极高密度乳腺女性基线DCE MRI上强化实质体积高者乳腺癌发生风险约为低者的2倍(HR 2.09)。
- 强化实质体积每增加一个单位,乳腺癌发生风险相关HR为1.09(95%CI 1.01-1.18)。
- 五个主成分解释96%方差,其中解释最大独立方差(42%)的成分与强化实质体积相关。
核心结论
- 在极高密度乳腺女性中,基线DCE MRI上强化实质体积高与乳腺癌发生增加相关(相比强化实质体积低者)。
研究设计与样本
- Dense Tissue and Early Breast Neoplasm Screening试验的二次分析,纳入4553例极高密度乳腺女性(平均年龄55.7岁±6[SD]),MRI于2011年12月至2016年1月在八家医院进行,从基线DCE MRI提取纤维腺体组织分割后的实质定量特征(包括体积密度、体积形态和强化特征),采用主成分分析识别方差最大的实质指标,多变量Cox比例风险回归评估乳腺癌发生与定量实质特征的关联,并将显著特征按三分位分层。
诊断标准与关键数值
- 识别出五个主成分解释96%的方差,其中解释最大独立方差(42%)的成分由与强化实质体积相关的MRI特征组成;多变量分析显示强化实质体积与乳腺癌发生相关(HR 1.09;95%CI:1.01,1.18;P=0.02);强化实质体积高三分位组女性乳腺癌发生率为低三分位组的2倍(HR 2.09;95%CI:1.25,3.61;P=0.005)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Automated identification of quantitative breast parenchymal enhancement features on dynamic contrast-enhanced (DCE) MRI scans could provide added value in assessment of breast cancer risk in women with extremely dense breasts. Purpose To automatically identify quantitative properties of the breast parenchyma on baseline DCE MRI scans and assess their association with breast cancer occurrence in women with extremely dense breasts. Materials and Methods This study represents a secondary analysis of the Dense Tissue and Early Breast Neoplasm Screening trial. MRI was performed in eight hospitals between December 2011 and January 2016. After segmentation of fibroglandular tissue, quantitative features (including volumetric density, volumetric morphology, and enhancement characteristics) of the parenchyma were extracted from baseline MRI scans. Principal component analysis was used to identify parenchymal measures with the greatest variance. Multivariable Cox proportional hazards regression was applied to assess the association between breast cancer occurrence and quantitative parenchymal features, followed by stratification of significant features into tertiles. Results A total of 4553 women (mean age, 55.7 years ± 6 [SD]) with extremely dense breasts were included; of these women, 122 (3%) were diagnosed with breast cancer. Five principal components representing 96% of the variance were identified, and the component explaining the greatest independent variance (42%) consisted of MRI features relating to volume of enhancing parenchyma. Multivariable analysis showed that volume of enhancing parenchyma was associated with breast cancer occurrence (hazard ratio [HR], 1.09; 95% CI: 1.01, 1.18; P = .02). Additionally, women in the high tertile of volume of enhancing parenchyma showed a breast cancer occurrence twice that of women in the low tertile (HR, 2.09; 95% CI: 1.25, 3.61; P = .005). Conclusion In women with extremely dense breasts, a high volume of enhancing parenchyma on baseline DCE MRI scans was associated with increased occurrence of breast cancer as compared with a low volume of enhancing parenchyma. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Grimm in this issue.
引用
- Wang H, van der Velden BHM, Verburg E, et al. Assessing Quantitative Parenchymal Features at Baseline Dynamic Contrast-enhanced MRI and Cancer Occurrence in Women with Extremely Dense Breasts. Radiology. 2023. PMID: 37552061. doi:10.1148/radiol.222841
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。