文献速递泌尿生殖腹部MR

基于深度学习重建对T2加权和扩散加权前列腺MRI图像质量的评估

Assessment of deep learning-based reconstruction on T2-weighted and diffusion-weighted prostate MRI image quality.
PubMed 文献 · Eur J Radiol · 2023-07-28

纳入40例患者,评估不同深度学习重建(DLR)降噪水平及成像参数对前列腺T2WI和DWI定量与定性图像质量、PI-RADS分类及检查时间的影响。所有DLR水平均显著提高SNR和CNR;DLR使快速T2WI和快速DWI采集时间分别缩短33%和49%而不影响图像质量,高分辨率T2WI空间分辨率提高73%;DLR不改变PI-RADS分类。

要点

  • DLR各降噪水平均较DLR关闭显著提高SNR和CNR
  • DLR下快速T2WI和快速DWI采集时间分别缩短33%和49%且图像质量不受影响
  • DLR不改变PI-RADS分类,可用于加速前列腺MRI协议

核心结论

  • DLR可缩短T2WI和DWI采集时间并提高SNR和CNR,而不损害图像质量或不改变PI-RADS分类。

研究设计与样本

  • 纳入40例患者,对标准护理前列腺MRI序列(T2WI和DWI)分别在不使用和使用不同DLR降噪水平(低、中、高)下重建,并评估快速T2WI、快速DWI和高分辨率T2WI序列;定量分析包括SNR、CNR和ADC值,由两名放射科医生独立采用5分量表定性评估图像质量和伪影,由更有经验的放射科医生进行PI-RADS分类。

诊断标准与关键数值

  • 所有DLR水平较DLR关闭采集的SNR和CNR显著更高
  • 与标准护理相比,DLR使快速T2WI采集时间缩短33%,快速DWI采集时间缩短49%,且不影响图像质量
  • 与标准护理相比,高分辨率T2WI联合DLR使相位编码方向空间分辨率提高73%
  • T2WI和DWI所有主观测量指标的阅片者间一致性均为中等(substantial)
  • 快速T2WI联合DLR中等降噪水平与快速DWI联合DLR低降噪水平获得最高定性质量评分

临床应用与阅片要点

  • DLR可在不改变PI-RADS分类的前提下用于缩短前列腺T2WI和DWI采集时间

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the impact of a commercially available deep learning-based reconstruction (DLR) algorithm with varying combinations of DLR noise reduction settings and imaging parameters on quantitative and qualitative image quality, PI-RADS classification and examination time in prostate T2-weighted (T2WI) and diffusion-weighted (DWI) imaging.

METHOD: Forty patients were included. Standard-of-care (SoC) prostate MRI sequences including T2WI and DWI were reconstructed without and with different DLR de-noising levels (low, medium, high). In addition, faster T2WI(Fast) and DWI(Fast) sequences, and a higher resolution T2WI(HR) sequence were evaluated. Quantitative analysis included signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and apparent diffusion coefficient (ADC) values. Two radiologists performed qualitative analysis, independently evaluating imaging datasets using 5-point scoring scales for image quality and artifacts. PI-RADS category assignment was also performed by the more experienced radiologist.

RESULTS: All DLR levels resulted in significantly higher SNR and CNR compared to the DLR(off) acquisitions. DLR allowed the acquisition time to be reduced by 33% for T2WI(Fast) and 49% for DWI(Fast) compared to SoC, without affecting image quality, whilst T2WI(HR) with DLR allowed for a 73% increase in spatial resolution in the phase encode direction compared to SoC. The inter-reader agreement for image quality and artifact scores was substantial for all subjective measurements on T2WI and DWI. The T2WI(Fast) protocol with DLR(medium) and DWI(Fast) with DLR(low) received the highest qualitative quality score.

CONCLUSION: DLR can reduce T2WI and DWI acquisition time and increase SNR and CNR without compromising image quality or altering PI-RADS classification.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Lee KL, Kessler DA, Dezonie S, et al. Assessment of deep learning-based reconstruction on T2-weighted and diffusion-weighted prostate MRI image quality. Eur J Radiol. 2023. PMID: 37541181. doi:10.1016/j.ejrad.2023.111017

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。