文献速递腹部US

CEUS LI-RADS 2017版LR-M类肝结节不同尺寸多种修改标准方法的诊断效能:临床实践与讨论

Efficacy of Multiple Modified Methods of Criteria for LR-M Liver Nodules of Different Sizes: Clinical Practice and Discussion in CEUS LI-RADS Version 2017.
PubMed 文献 · J Ultrasound Med · 2023-08-16

这项回顾性研究纳入2019至2021年具有HCC高风险且CEUS LI-RADS 2017版判为LR-M的连续患者,用四种修改的LR-M方法评估不同尺寸结节的诊断效能。261例LR-M观察中包括166例HCC和95例非HCC;按尺寸分为<30 mm组A(133个结节)、30-50 mm组B(78个结节)和>50 mm组C(50个结节)。全部LR-M结节中四种标准的AUC无显著差异;组B中标准IV的AUC显著高于标准I和III,组C中标准IV的AUC无显著差异。作者认为按肿瘤尺寸选择适当的修改LR-M诊断标准可有效提高LR-M的诊断效能。

要点

  • 全部LR-M结节中,标准I、II、III、IV的AUC无显著差异。
  • 30-50 mm组中,标准IV的AUC显著高于标准I和III。
  • 按尺寸选择修改的LR-M标准可能改善LR-M结节的诊断效能。

核心结论

  • 修改的LR-M方法可调节鉴别HCC与其他病变的检测效能,按肿瘤尺寸选择适当的修改LR-M诊断标准可有效提高LR-M的诊断效能。

研究设计与样本

  • 回顾性研究,纳入2019至2021年具有HCC高风险且CEUS LI-RADS 2017版判为LR-M的连续患者261例(166例HCC、95例非HCC),按结节尺寸分为<30 mm组A(133个)、30-50 mm组B(78个)、>50 mm组C(50个),用四种修改LR-M方法评估并以AUC比较诊断效能。

诊断标准与关键数值

  • 全部LR-M结节中标准I、II、III、IV的AUC无显著差异;组A中四种标准的AUC无显著差异;组B中标准IV的AUC显著高于标准I和III,标准I与标准III的AUC均无显著差异;组C中标准IV的AUC无显著差异。

临床应用与阅片要点

  • 作者认为按肿瘤尺寸选择适当的修改LR-M诊断标准可有效提高LR-M的诊断效能。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To assess the diagnostic performance of the modified LR-M method of CEUS LI-RADS version 2017 with nodules of different sizes.

METHODS: This retrospective study included consecutive patients with high risk for HCC who underwent CEUS between 2019 and 2021, demonstrating an LR-M observed using CEUS LI-RADS version 2017. Four modified LR-M methods were used to evaluate nodules of different sizes. The diagnostic performances of the four modified LR-M methods were assessed in LR-M nodules of different sizes by the area under the receiver operating characteristic curve (AUC).

RESULTS: The 261 patients with LR-M observations included 166 HCCs and 95 non-HCCs. A total of 133 nodules were <30 mm and defined as group A, 78 nodules were 30-50 mm in size and defined as group B, and 50 nodules were >50 mm and defined as group C. The AUCs between criterion I, II, III, and IV were not significantly different in all LR-M nodules. The AUCs of the ROC curves between criterion I, II, III, and IV were not significantly different in group A. However, the AUC of criterion IV was significantly higher than that of criterion I and III in group B, and the AUCs of criterion I and criterion III were both not significant in group B; the AUC of criterion IV was not significant in group C.

CONCLUSIONS: The modified LR-M method could moderate the detection effectiveness in differentiating HCC from other lesions. According to tumor size, the selection of appropriate modified LR-M diagnostic criteria could effectively improve the diagnostic performance of LR-M.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Lin W, He N, Zeng Q, et al. Efficacy of Multiple Modified Methods of Criteria for LR-M Liver Nodules of Different Sizes: Clinical Practice and Discussion in CEUS LI-RADS Version 2017. J Ultrasound Med. 2023. PMID: 37584497. doi:10.1002/jum.16308

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。